FDA device news · Product code HRS

FDA 510(k) clearance

I.T.S. PRS Phoenix II (K260054): I.T.S. GmbH 510(k) clearance

Laßnitzhöhe, AT

Follow HRS: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Apr 24, 2026
Received
Jan 8, 2026
510(k) type
Traditional
Product code
HRSPlate, Fixation, Bone
Review panel
Orthopedic
Device class
Class II
Regulation
21 CFR 888.3030
Third-party review
No
Summary or statement
Summary
Review time
106 daysreceipt to decision, calendar days
Median in HRS
82 daysthe latest 25 other decisions
HRS decisions
60in the last 12 months
Applicant’s 510(k)s
8in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The I.T.S. PRS Phoenix II is a set of metal plates and screws used to hold broken pelvic bones in place while they heal. The plates are made of titanium and are shaped to fit the pelvis. The set includes symphysis, anterior column, posterior column, and other plate types, along with cortical and cancellous screws of several diameters.
What it’s cleared for
It is cleared to stabilize one or more pelvic bone fractures in adult patients. The listed uses include symphyseal disruptions, sacroiliac joint disruptions, acetabular and posterior wall fractures, pelvic ring fractures, and revision surgery for pseudoarthrosis, non-unions, and malunions. It is not intended for spinal use.
Compared with (the predicate)
  • K210935, I.T.S. Pelvic Reconstruction System PRS RX & PRS Phoenix
  • K063166, I.T.S. Pelvic Reconstruction System
  • K223772, Stryker PRO Plating System, Stryker Trauma Pelvic Set (Matta)
  • K221809, DePuy Synthes 3.5mm Intrapelvic Acetabular System
How it differs
The summary states the device is similar to its predicates in material, geometry, design, indications, and operational principles. It does not describe specific differences from the predicate devices.
Testing the summary lists
  • Engineering analysis (finite element analysis) per ASTM F382 to compare load capacity with the cleared device
  • Screw testing per ASTM F543 compared to a 2024 FDA guideline for non-spinal metallic bone screws
  • Sterility and bioburden (ISO 11137-1, -2, -3), endotoxin (Ph. Eur. 2.6.14 / USP <85>), and cytotoxicity (ISO 10993-5) on worst-case products

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K260054 took 106 calendar days from receipt to decision. Of the latest 25 other decisions in product code HRS, 5 took longer, 20 were faster; their median was 82 days.

Latest decisions in HRS

NumberDevice and applicantDecision and review time
K262939 HERO Sternal Closure SystemHero Orthopedics, LLC · Traditional Nov 2, 202673 days
K263602 Arthrex Plates, Screws and Pins, and WashersArthrex, Inc. · Special Oct 29, 202629 days
K261135 Trochlear Salvage Plating SystemSkeletal Dynamics, Inc. · Traditional Oct 26, 2026202 days
K262779 ANTHEM™ Fracture SystemGlobus Medical, Inc. · Traditional Oct 23, 202679 days
K263407 Tempo Plating SystemPace Surgical · Special Oct 23, 202628 days
K263269 Park's Pectus SystemTdm Co., Ltd. · Special Oct 15, 202627 days
K261611 TDM Large Bone Plate and Screw SystemTdm Co., Ltd. · Special Oct 2, 2026140 days
K262649 Alians ForearmNewclip Technics · Traditional Sep 28, 202660 days
K261892 ProRib Fixation SystemCosta Surgical, Inc. · Traditional Sep 23, 2026110 days
K262098 EnHAnce PEEK Bunion SystemNvision Biomedical Technologies · Special Sep 18, 202688 days

Other 510(k)s from I.T.S. GmbH

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K260958 I.T.S. Clavicle Plates with Angular Stability; I.T.S. Volar Radius Plate with Angular Stability; I.T.S. Humeral Head Plate with Angular Stability; I.T.S. FR.O.H. Calcaneus Repair System; I.T.S. Pilonplate with Angular Stability; I.T.S. Olecranonplate with Angular Stability; I.T.S. Straight Plate with Angular Stability; I.T.S. Screw System; I.T.S. PRS Sacral Rod System; I.T.S. Fibula Plate PROlock with Angular Stability; I.T.S. Distal Humeral Plates with Angular Stability; I.T.S. LRS (LI.T.S. GmbH · Traditional Jun 16, 202685 days
K233134 I.T.S. INS Proximal Femur NailI.T.S. GmbH · Traditional Feb 12, 2024138 days
K210935 I.T.S. Pelvic Reconstruction System (PRS RX & PRS Phoenix)I.T.S. GmbH · Traditional Aug 31, 2022520 days
K142418 I.T.S. Hand Locking Plates System - HLSI.T.S. GmbH · Traditional Sep 26, 201429 days
K132945 CFN-CANNULATED FEMUR NAIL, CTN-CANNULATED TIBIA NAIL, CHN-CANNULATED HUMERAL NAILI.T.S. GmbH · Traditional Mar 7, 2014169 days
K131722 I.T.S. EXTREMITY FIXATION SYSTEMSI.T.S. GmbH · Traditional Aug 7, 201356 days
K130008 DISTAL ULNA LOCKING PLATE (DUL), ULNA OSTEOTOMY LOCKING PLATE (UOL), 3.0 CANCELLOUS LOCKING SCREW, 3.0 CORTICAL LOCKINGI.T.S. GmbH · Traditional Jun 25, 2013174 days

Watch HRS in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get HRS every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in HRS. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.