FDA device news · Product code IZF
FDA 510(k) clearance
Adaptix Ortho350 (K252133): Adaptix Limited 510(k) clearance
Oxford, GB
- Decision
- Substantially Equivalent
- Decision date
- Nov 6, 2025
- Received
- Jul 7, 2025
- 510(k) type
- Traditional
- Product code
- IZFSystem, X-Ray, Tomographic
- Review panel
- Radiology
- Device class
- Class II
- Regulation
- 21 CFR 892.1740
- Third-party review
- Yes
- Summary or statement
- Summary
- Review time
- 122 daysreceipt to decision, calendar days
- Median in IZF
- 118 daysthe latest 24 other decisions
- IZF decisions
- 1in the last 12 months
- Applicant’s 510(k)s
- 1in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The Adaptix Ortho350 is a portable 3D tomographic X-ray system, made of a C-arm assembly and a control PC. It takes many low-dose X-ray images from different positions and combines them into slice-like 3D images (tomosynthesis) of body parts, such as a patient's hand or leg, placed against the detector.
- What it’s cleared for
- It is cleared to generate tomosynthesis images of body extremities, upper and lower limbs, and adjacent anatomy for diagnostic purposes in routine radiography, for adult and pediatric patients, used by qualified or trained doctors or technicians in hospitals, clinics, imaging centers, and other healthcare facilities. It is not indicated for imaging the skull, chest, spinal column, hip, shoulder, or for mammography.
- Compared with (the predicate)
- K221949, ADAPTIX 3D Orthopedic Imaging System
- How it differs
- The summary says the Ortho350 has a larger detector (16 cm x 24 cm versus 15 cm x 12 cm), a higher bit depth, a higher maximum kV (70 kV versus 60 kV), a larger source-to-image distance (35 cm versus 20 cm), a heavier C-arm and computer, a base plate instead of a stand, and wider operating and storage ranges. It also adds an isolation transformer.
- Testing the summary lists
- Biocompatibility (ISO 10993-1)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K252133 took 122 calendar days from receipt to decision. Of the latest 24 other decisions in product code IZF, 11 took longer, 12 were faster, 1 took the same time; their median was 118 days.
Latest decisions in IZF
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K252649 | TAP2DNano-X Imaging , Ltd. · Traditional | Feb 2, 2026165 days |
| K252133 | Adaptix Ortho350Adaptix Limited · Traditional | Nov 6, 2025122 days |
| K250850 | Nanox.ARC XNano-X Imaging , Ltd. · Traditional | Apr 16, 202527 days |
| K242395 | Nanox.ARCNano-X Imaging , Ltd. · Traditional | Dec 4, 2024113 days |
| K222934 | Nanox.ARCNano-X Imaging , Ltd. · Traditional | Apr 28, 2023214 days |
| K221949 | Ortho Device, ADAPTIX 3D Orthopedic Imaging SystemPausch Medical GmbH · Traditional | Jan 26, 2023205 days |
| K213081 | CLISIS SYSTEMS, Discovery RF180General Medical Merate S.P.A · Traditional | Oct 26, 202133 days |
| K193262 | DR 600 with TomosynthesisAgfa N.V. · Traditional | Mar 9, 2020104 days |
| K183275 | DR 800 with TomosynthesisAgfa N.V. · Traditional | Feb 1, 201970 days |
| K132261 | DISCOVERY XR656 WITH VOLUMERAD (DIGITAL TOMOSYNTHESIS)Ge Medical Systems, LLC · Traditional | Nov 18, 2013122 days |
Other 510(k)s from Adaptix Limited
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
This is the only 510(k) in openFDA under this applicant name.
Watch IZF in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get IZF every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in IZF. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K252133Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:IZFRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:IZFRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:IZF AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Adaptix Limited"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil