FDA device news · Product code DQA

FDA 510(k) clearance

Unimed Reusable SpO2 Sensors (-48 Series and -29 Series) (U410-48, U410-29) (K251696): Unimed Medical Supplies, Inc. 510(k) clearance

Shenzhen, CN

Follow DQA: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Dec 1, 2025
Received
Jun 2, 2025
510(k) type
Traditional
Product code
DQAOximeter
Review panel
Cardiovascular
Device class
Class II
Regulation
21 CFR 870.2700
Third-party review
No
Summary or statement
Summary
Review time
182 daysreceipt to decision, calendar days
Median in DQA
176 daysthe latest 24 other decisions
DQA decisions
12in the last 12 months
Applicant’s 510(k)s
20in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The Unimed Reusable SpO2 Sensors (models U410-48 and U410-29) are finger clip sensors for measuring blood oxygen. Each sensor has a connector, a cable, and a reusable part that holds a light-emitting diode (LED) and a photodetector, which shine light through the finger and measure how much is absorbed. The sensors are supplied non-sterile and are designed to work with a Mindray M12 monitor.
What it’s cleared for
The sensors are cleared for continuous, non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate in adult patients weighing more than 30 kg who are well or poorly perfused, applied to the finger. They are for no-motion use in professional healthcare settings and are prescription only.
Compared with (the predicate)
  • K142832, Unimed Disposable and Reusable SPO2 Sensors
How it differs
The summary says the device is limited to adult patients over 30 kg, while the predicate is also cleared for pediatric patients weighing 10 to 50 kg and neonatal patients weighing at least 3 kg.
Testing the summary lists
  • Electrical safety (IEC 60601-1, including amendments)
  • Electromagnetic disturbances (IEC 60601-1-2)
  • Pulse oximeter particular requirements (ISO 80601-2-61)
  • Biocompatibility: cytotoxicity (ISO 10993-5), skin sensitization (ISO 10993-10), skin irritation (ISO 10993-23)
  • Performance tests: saturation accuracy of ±3% (70-100%) and pulse rate accuracy of ±3 bpm (30-250 bpm), under no motion and low perfusion

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K251696 took 182 calendar days from receipt to decision. Of the latest 24 other decisions in product code DQA, 11 took longer, 12 were faster, 1 took the same time; their median was 176 days.

Latest decisions in DQA

NumberDevice and applicantDecision and review time
K261870 ANNE LimbSibel Health · Traditional Nov 5, 2026154 days
K260490 Ninenovo Blood Oxygen Ring (BORMB-01-6,BORMB-01-7,BORMB-01-8,BORMB-01-9,BORMB-01-10,BORMB-01-11,BORMB-01-12,BORMB-01-13,BORMB-01-14)Shenzhen Ninenovo Technology Limited · Traditional Oct 2, 2026231 days
K252821 Reusable Adult SpO2 Clip Sensor (3m) (M1196A); Reusable Adult SpO2 Clip Sensor (0.9m) (M1196T)Philips Medizin Systeme Böblingen GmbH · Traditional May 29, 2026267 days
K252655 Pulse Oximeter (PO-A2AO, PO-A2AT, PO-A3AO, PO-H1AO, PO-B1AO, PO-C5AO, PO-C5AT, PO-C6AO, PO-C6AT)Shenzhen Imdk Medical Technology Co., Ltd. · Traditional May 11, 2026262 days
K253887 Nasal Alar SpO2 Sensor (989803205381, 989803205391); Nasal Alar Sp02 Sensor (989803205401)Philips Medizin Systeme · Traditional May 1, 2026148 days
K260931 Unimed Reusable Finger Clip SpO2 Sensors (U403-49R and U103-49R)Unimed Medical Supplies, Inc. · Special Apr 14, 202625 days
K252448 AViTA Pulse Oximeter (SP61)Avita Corporation · Traditional Feb 27, 2026207 days
K252805 YUWELL® Finger Pulse Oximeter (YX105, YX106, YX110, YX310)Jiangsu Yuyue Medical Equipment & Supply Co., Ltd. · Traditional Feb 17, 2026167 days
K253109 Reusable SPO2 Sensor (BSA307-47; BSA109-50; BSA109-31O)Shenzhen Best Electronics Co., Ltd. · Traditional Jan 7, 2026105 days
K251751 Spo2 Sensor CSS032DShenzhen Ykd Technology Co., Ltd. · Traditional Dec 19, 2025193 days

Other 510(k)s from Unimed Medical Supplies, Inc.

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K253162 Temperature probes (T2252-PG, TCMA-AG, TCMA-PG, TMQ-DAG, THP-DAG)Unimed Medical Supplies, Inc. · Traditional Jun 5, 2026252 days
K260931 Unimed Reusable Finger Clip SpO2 Sensors (U403-49R and U103-49R)Unimed Medical Supplies, Inc. · Special Apr 14, 202625 days
K253964 Disposable Neonatal NIBP Cuff (U1681S-C51N)Unimed Medical Supplies, Inc. · Special Jan 9, 202629 days
K251691 Unimed Reusable SpO2 Sensors (-08 Series) (U403S-08, U203S-08, U103S-08, U103-08)Unimed Medical Supplies, Inc. · Traditional Dec 1, 2025182 days
K251693 Unimed Reusable SpO2 Sensors (-75 Series) (U410-75, U110-75, U410S-75, U110S-75, U210S-75)Unimed Medical Supplies, Inc. · Traditional Nov 18, 2025169 days
K251695 Unimed Reusable SpO2 Sensors (-06 Series) (U403S-06, U203S-06, U103S-06)Unimed Medical Supplies, Inc. · Traditional Nov 18, 2025169 days
K250931 Unimed Reusable SpO2 Sensors (-117 and -121 Series) (U403-117, U103-117, U410-121, U110-121)Unimed Medical Supplies, Inc. · Traditional Aug 13, 2025138 days
K251045 Disposable Neonatal NIBP Cuff (U1682S-C51N, U1683S-C51N, U1684S-C51N, U1685S-C51N)Unimed Medical Supplies, Inc. · Traditional Jul 15, 2025103 days
K243086 Unimed Reusable Finger Clip SpO2 Sensors (UXXX-91 Series) (U403-91, U410-91)Unimed Medical Supplies, Inc. · Traditional Feb 20, 2025143 days
K242580 Unimed Reusable Finger Clip SpO2 Sensors (U103-125, U403-254, U103-254, U403-125)Unimed Medical Supplies, Inc. · Traditional Feb 6, 2025160 days
K222213 Pulse Oximeter (UC-200, UC-201, UC-202, UC-203, UC-204, UC-100, UC-101, UC-102, UC-103, UC-104)Unimed Medical Supplies, Inc. · Traditional Dec 19, 2022147 days
K210019 Unimed CO2 Mainstream Module Model Capno-M, Unimed CO2 Mainstream Module Model Capno-M+Unimed Medical Supplies, Inc. · Traditional Mar 4, 202159 days

Watch DQA in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get DQA every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DQA. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.