FDA device news · Product code DQA
FDA 510(k) clearance
Nasal Alar SpO2 Sensor (989803205381, 989803205391); Nasal Alar Sp02 Sensor (989803205401) (K253887): Philips Medizin Systeme 510(k) clearance
Boblingen, DE
- Decision
- Substantially Equivalent
- Decision date
- May 1, 2026
- Received
- Dec 4, 2025
- 510(k) type
- Traditional
- Product code
- DQAOximeter
- Review panel
- Cardiovascular
- Device class
- Class II
- Regulation
- 21 CFR 870.2700
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 148 daysreceipt to decision, calendar days
- Median in DQA
- 182 daysthe latest 24 other decisions
- DQA decisions
- 12in the last 12 months
- Applicant’s 510(k)s
- 71in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The Nasal Alar SpO2 Sensor is a disposable, single patient use pulse oximetry sensor that clips onto the side of the nose (the nasal ala) to measure blood oxygen saturation (SpO2) and pulse rate. It uses light-emitting diodes and a photodiode and connects by cable to a compatible monitor. The summary says the nasal ala is used because it provides blood flow without the interruption that can occur at fingers or toes.
- What it’s cleared for
- The sensor is cleared for continuous noninvasive monitoring of SpO2 and pulse rate from the nasal ala in adult and pediatric patients who are at least 4 years old and weigh at least 15 kg, who are well or poorly perfused. It is used with compatible pulse oximetry monitors under professional supervision in a variety of healthcare environments.
- Compared with (the predicate)
- K171423, Nasal Alar SpO2 Sensor
- How it differs
- The summary says the new sensor uses a new glue formulation, updated colorants for the heat shrink tubing, and a new coverlay material. It also says a minor adjustment was made to the LED chip to improve manufacturing yield, that labeling was updated, and that the ingress protection rating is IP34, which is more stringent than the predicate's IPX1 rating.
- Testing the summary lists
- Biocompatibility (ISO 10993-1, -5, -6, -10, -11, -23)
- Electrical safety and electromagnetic compatibility (IEC 60601-1, IEC 60601-1-2)
- Pulse oximeter accuracy and clinical SpO2 testing (ISO 80601-2-61); the summary reports an overall ARMS of 3% or less
- Bench performance testing (pull, shelf-life aging per ASTM F1980, environmental reliability, LED transmission, pulse rate)
- Ingress protection (IP34) and mechanical and thermal safety
- Usability (IEC 60601-1-6) and clinical investigation good practice (ISO 14155)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K253887 took 148 calendar days from receipt to decision. Of the latest 24 other decisions in product code DQA, 19 took longer, 5 were faster; their median was 182 days.
Latest decisions in DQA
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K261870 | ANNE LimbSibel Health · Traditional | Nov 5, 2026154 days |
| K260490 | Ninenovo Blood Oxygen Ring (BORMB-01-6,BORMB-01-7,BORMB-01-8,BORMB-01-9,BORMB-01-10,BORMB-01-11,BORMB-01-12,BORMB-01-13,BORMB-01-14)Shenzhen Ninenovo Technology Limited · Traditional | Oct 2, 2026231 days |
| K252821 | Reusable Adult SpO2 Clip Sensor (3m) (M1196A); Reusable Adult SpO2 Clip Sensor (0.9m) (M1196T)Philips Medizin Systeme Böblingen GmbH · Traditional | May 29, 2026267 days |
| K252655 | Pulse Oximeter (PO-A2AO, PO-A2AT, PO-A3AO, PO-H1AO, PO-B1AO, PO-C5AO, PO-C5AT, PO-C6AO, PO-C6AT)Shenzhen Imdk Medical Technology Co., Ltd. · Traditional | May 11, 2026262 days |
| K253887 | Nasal Alar SpO2 Sensor (989803205381, 989803205391); Nasal Alar Sp02 Sensor (989803205401)Philips Medizin Systeme · Traditional | May 1, 2026148 days |
| K260931 | Unimed Reusable Finger Clip SpO2 Sensors (U403-49R and U103-49R)Unimed Medical Supplies, Inc. · Special | Apr 14, 202625 days |
| K252448 | AViTA Pulse Oximeter (SP61)Avita Corporation · Traditional | Feb 27, 2026207 days |
| K252805 | YUWELL® Finger Pulse Oximeter (YX105, YX106, YX110, YX310)Jiangsu Yuyue Medical Equipment & Supply Co., Ltd. · Traditional | Feb 17, 2026167 days |
| K253109 | Reusable SPO2 Sensor (BSA307-47; BSA109-50; BSA109-31O)Shenzhen Best Electronics Co., Ltd. · Traditional | Jan 7, 2026105 days |
| K251751 | Spo2 Sensor CSS032DShenzhen Ykd Technology Co., Ltd. · Traditional | Dec 19, 2025193 days |
Other 510(k)s from Philips Medizin Systeme
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K252821 | Reusable Adult SpO2 Clip Sensor (3m) (M1196A); Reusable Adult SpO2 Clip Sensor (0.9m) (M1196T)Philips Medizin Systeme Böblingen GmbH · Traditional | May 29, 2026267 days |
| K253654 | IntelliVue Measurement Rack 6000 (867317)Philips Medizin Systeme Böblingen GmbH · Traditional | Mar 30, 2026130 days |
| K252726 | IntelliVue Multi-Measurement Module X3 (867030); IntelliVue Patient Monitor MX100 (867033); IntelliVue MMX (867036)Philips Medizin Systeme Boeblingen GmbH · Traditional | Feb 6, 2026162 days |
| K251702 | IntelliVue Patient Monitor MX750; IntelliVue Patient Monitor MX850; IntelliVue 4-Slot Module Rack FMX-4 (866471 866470 866468 )Philips Medizin Systeme Böblingen GmbH · Traditional | Nov 10, 2025161 days |
| K251146 | IntelliVue Patient monitors MX400, MX450, MX500, MX550Philips Medizin Systeme Boeblingen GmbH · Traditional | Oct 17, 2025186 days |
| K250453 | IntelliVue Patient Monitor 6100 (6100); IntelliVue Patient Monitor 6300 (6300); IntelliVue Patient Monitor 6500 (6500)Philips Medizin Systeme Böblingen GmbH · Traditional | Sep 2, 2025196 days |
| K242962 | Telemetry Monitor 5500 Release 4.0 (867232)Philips Medizin Systeme Böblingen GmbH · Traditional | May 5, 2025222 days |
| K241890 | Philips Holter Analysis SystemPhilips Medizin Systeme Böblingen GmbH · Traditional | Mar 21, 2025266 days |
| K243545 | Philips Reusable ECG Lead Sets and Trunk Cables : Model Number,Model Name: 989803170171, OR 3-Lead ECG Trunk Cable, AAMI/IEC; 989803170181, OR 5-Lead ECG Trunk Cable, AAMI/IEC; M1667A, 6 Lead ECG Trunk, AAMI/IEC 2.7m; M1668A,5 Lead ECG Trunk, AAMI/IEC 2.7m; M1669A,3 Lead ECG Trunk, AAMI/IEC 2.7m; M1949A,5+5 ECG Trunk cable AAMI, IEC 2.7m; M1663A,10 Lead ECG Trunk AAMI/IEC 2m; M1665A, 6+4 Lead ECG Trunk AAMI/IEC 2.7m; M1671A, 3 Leadset, Grabber, AAMI, ICU; M1673A, 3 Leadset, SnPhilips Medizin Systeme Böblingen GmbH · Traditional | Jan 17, 202563 days |
| K241556 | Cardiac Workstation (5000, 7000)Philips Medizin Systeme Böblingen GmbH · Traditional | Dec 17, 2024200 days |
| K233440 | Avalon CL Fetal & Maternal (F&M) Pod (866488), Avalon CL Fetal & Maternal (F&M) Patch (989803196341)Philips Medizin Systeme Boeblingen GmbH · Traditional | Jul 2, 2024258 days |
| K231671 | IntelliVue Patient Monitor MX750 (866471), IntelliVue Patient Monitor MX850 (866470), IntelliVue 4-Slot Module Rack FMX-4 (866468)Philips Medizin Systeme Boeblingen GmbH · Traditional | Dec 19, 2023194 days |
Watch DQA in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get DQA every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DQA. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K253887Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DQARetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:DQARetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DQA AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Philips Medizin Systeme"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil