FDA device news · Product code FYA
FDA 510(k) clearance
Surgical Gown (Level 3: S, M, L, XL, XXL, XXXL) (K250564): Yadu Medical (Henan) Co., Ltd. 510(k) clearance
He Nan, CN
- Decision
- Substantially Equivalent
- Decision date
- Dec 3, 2025
- Received
- Feb 26, 2025
- 510(k) type
- Traditional
- Product code
- FYAGown, Surgical
- Review panel
- General, Plastic Surgery
- Device class
- Class II
- Regulation
- 21 CFR 878.4040
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 280 daysreceipt to decision, calendar days
- Median in FYA
- 190 daysthe latest 24 other decisions
- FYA decisions
- 10in the last 12 months
- Applicant’s 510(k)s
- 3in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- A single-use, disposable surgical gown worn by healthcare staff during surgery. It is supplied sterile (sterilized with ethylene oxide gas) and comes in standard and reinforced versions, with reinforced areas meant to resist fluid penetration. The gown is designed for short to medium length procedures with moderate risk, rated Level 3 under the AAMI PB70 liquid barrier classification.
- What it’s cleared for
- The gown is cleared to be worn by healthcare professionals during surgical procedures to provide barrier protection against the transfer of microorganisms, body fluids, and particulate matter in critical surgical zones, for both patients and healthcare personnel. The summary states the products meet Level 3 liquid barrier requirements in ANSI/AAMI PB70:2022.
- Compared with (the predicate)
- K190950, Medline Level 2 Surgical Gown (Eclipse Non-Reinforced), Medline Level 3 Surgical Gown (Eclipse Fabric Reinforced), Medli
- How it differs
- The summary says the device is offered only in Level 3, while the predicate family includes Level 2 gowns; the intended use wording differs slightly; the sizes offered differ (S to XXXL versus S to XXXX-Large); and the materials differ, with the subject reinforced gown using a different laminated material than the predicate.
- Testing the summary lists
- Biocompatibility (ISO 10993-5 and ISO 10993-10): reported as non-cytotoxic, non-irritating and non-sensitizing under the test conditions
- Penetration (AATCC 42): acceptance limit of 1.0 g or less, reported as pass
- Hydrostatic pressure (AATCC 127): acceptance limit of 50 cm H2O or more, reported as pass
- Wet and dry state microbial penetration: no penetration allowed, reported as pass
- Linting, tensile strength, burst strength, flammability, tear strength and seam strength: all reported as pass against their listed criteria
- No clinical study was included in this submission
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K250564 took 280 calendar days from receipt to decision. Of the latest 24 other decisions in product code FYA, 1 took longer, 23 were faster; their median was 190 days.
Latest decisions in FYA
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260407 | Principle & Will ANSI/AAMI PB 70 (Sterile/Non-sterile) Level 3 Surgical Gowns (Reinforced) and Principle & Will ANSI/AMMI PB70 (Sterile/Non-sterile) Level 4 Surgical Gowns/Isolation GownsPrinciple & Will Co., Ltd. · Traditional | Aug 26, 2026198 days |
| K261028 | Surgical Gown Level2 (S, M, L, XL, XXL, XXXL)Yadu Medical (Henan) Co., Ltd. · Traditional | Aug 7, 2026130 days |
| K261949 | NYES Tuff Cuff L3 Disposable GownsNew York Embroidery Studio · Special | Jul 10, 202629 days |
| K252575 | Tuff Cuff™ Disposable Surgical Gowns AAMI L4 Sterile-Large (ML-L4-STL-DC-L)New York Embroidery Studio (NYES) · Traditional | Jun 4, 2026294 days |
| K260725 | BAÜMER Surgical Gowns (COP01, COP04, COP05, COP10)Hindernis DE Mexico, S.A.P.I. DE C.V. · Traditional | May 12, 202668 days |
| K253243 | Cardinal Health™ Poly Reinforced Surgical GownCardinal Health 200, LLC · Abbreviated | Apr 28, 2026211 days |
| K253003 | Non-sterile Level 3 Surgical Gown (4025); Sterile Level 3 Surgical Gown (M4025); Non-sterile Reinforced Level 4 Surgical Gown (G4025); Reinforced Sterile Level 4 Surgical Gown (GM4025)Hubei Xinxin Non-Woven Co., Ltd. · Traditional | Apr 20, 2026213 days |
| K251860 | Copioumed AAMI 3 Surgical GownCopioumed International, Inc. · Traditional | Feb 26, 2026254 days |
| K252301 | Henan Yadu Level 4 Surgical Gowns (Reinforced)Yadu Medical (Henan) Co., Ltd. · Traditional | Feb 4, 2026195 days |
| K250564 | Surgical Gown (Level 3: S, M, L, XL, XXL, XXXL)Yadu Medical (Henan) Co., Ltd. · Traditional | Dec 3, 2025280 days |
Other 510(k)s from Yadu Medical (Henan) Co., Ltd.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
Watch FYA in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get FYA every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in FYA. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K250564Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:FYARetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:FYARetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:FYA AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Yadu Medical Henan Co., Ltd."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil