Product codes

FDA product code

SEG: Leadless Cardiac Resynchronization Therapy (Crt) (FDA product code)

Follow SEG: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class III
Regulation
None listed
Review panel
Cardiovascular
Premarket route
PMA
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
PMA decisions
61 original PMA, the rest supplements
Median review time
29 daysthe latest 6 decisions
Recall records
00 in the last 12 months
Adverse event reports
78last 12 months, 6 deaths

PMA decisions

Original PMAs and supplements for product code SEG per year, by decision date, 6 since 2025. Review time is the days from receipt to decision.

All of them in the FDA’s PMA database

PMA decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20255
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
P240028 S006 WiSE® (Wireless Stimulation of the Endocardium Technology) CRT SystemEBR Systems, Inc. Mar 27, 202630 days
P240028 S004 WiSE® (Wireless Stimulation of the Endocardium Technology) CRT SystemEBR Systems, Inc. Dec 15, 202528 days
P240028 S003 WiSE (Wireless Stimulation of the Endocardium Technology) CRT SystemEBR Systems, Inc. Oct 3, 202523 days
P240028 S002 WiSE® (Wireless Stimulation of the Endocardium Technology) CRT SystemEBR Systems, Inc. Sep 3, 202528 days
P240028 S001 WiSE® (Wireless Stimulation of the Endocardium Technology) CRT SystemEBR Systems, Inc. Jun 18, 202530 days
P240028 WiSE® (Wireless Stimulation of the Endocardium Technology) CRT SystemEBR Systems, Inc. Apr 11, 2025225 days

Recalls

Recall records for product code SEG per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code SEG. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20210
20220
20230
20240
202543
2026 (so far)70

Last 12 months by event type

  • Deaths6
  • Injuries22
  • Malfunctions50
  • Other or not stated0

Most reported device problems, last 12 months

  1. Human-Device Interface Problem18
  2. Communication or Transmission Problem14
  3. Adverse Event Without Identified Device or Use Problem12
  4. No Apparent Adverse Event6
  5. Insufficient Device Problem Information5
  6. Intermittent Capture3

In plain English: what the newest reports describe Written by AI

  • Patients developed ventricular fibrillation, a dangerous heart rhythm, during routine echocardiograms shortly after implant. One report describes a patient shocked back by an implanted defibrillator and another describes a death. The manufacturer paused implant procedures and noted a possible link to the ultrasound probe near the device.

    4 reports: 3013596742-2026-00053, 3013596742-2026-00054, 25531810, MW5189421

  • After the electrode was released or repositioned, it came loose and moved (dislodged) in several reports. In one, it was retrieved with a snare; in another, retrieval failed. The manufacturer linked one dislodgement to the delivery sheath's pressure during release.

    3 reports: 3013596742-2026-00063, 3013596742-2026-00056, 3013596742-2026-00052

  • Some patients had signal and pacing problems. In one report the transmitter was found flipped, and the device could not track the electrode. In another, the device could not be read by the programmer, pacing in both ventricles was lost, and the patient's condition worsened. The manufacturer's findings on cause were not stated.

    2 reports: 3013596742-2026-00050, 3013596742-2026-00062

  • Parts of the implanted battery and transmitter caused problems under the skin. In one report, the skin over the battery eroded and the device was exposed, so the battery and transmitter were removed. In another, a patient with a flank hematoma needed a blood transfusion. The report says no device malfunction was found, and it does not state a link to the device.

    2 reports: 3013596742-2026-00068, 3013596742-2026-00060

  • During one implant attempt, fluid around the heart (pericardial effusion) was seen before the electrode was placed and kept growing. About 600 cc of blood was drained, and the procedure was stopped. The report describes very high clotting time and low blood pressure during the case.

    Report: 3013596742-2026-00064

Written by AI from the narratives of the 14 newest reports that have one, received Jun 15, 2026 to Sep 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
5in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Watch SEG in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get SEG every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in SEG. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.