Product codes

FDA product code

SAK: Software Device To Aid In The Prediction Or Diagnosis Of Sepsis (FDA product code)

Follow SAK: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 880.6316
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
21 in the last 12 months
Median review time
377 daysthe latest 2 decisions
Recall records
00 in the last 12 months
Adverse event reports
18last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code SAK per year, by decision date, 2 since 2024. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K250680 Bayesian Health Sepsis Flagging DeviceBayesian Health, Inc. Apr 30, 2026420 days
DEN230036 Sepsis ImmunoScorePrenosis, Inc. Apr 2, 2024333 days

Recalls

Recall records for product code SAK per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code SAK. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20210
20220
20230
20243
202514
2026 (so far)18

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions18
  • Other or not stated0

Most reported device problems, last 12 months

  1. Computer Software Problem10
  2. Application Program Version or Upgrade Problem2
  3. Communication or Transmission Problem2
  4. Delayed Program or Algorithm Execution2
  5. Data Back-Up Problem1
  6. Failure to Read Input Signal1

In plain English: what the newest reports describe Written by AI

  • Across many reports, the software was slow to process patient data and send notifications, so alerts reached clinicians late. The reported causes differed, including a network outage, a stalled record, a failed server, a duplicate program using too many resources, and sudden spikes in incoming data. The reports that address patient harm say none was reported.

    8 reports: 1931259-2026-00011, 1931259-2026-00010, 1931259-2026-00002, 1931259-2025-00018, 1931259-2026-00018, 1931259-2026-00014, 1931259-2026-00012, 1931259-2026-00013

  • Two reports describe backlogs that built up after a software upgrade, when a large increase in incoming data slowed processing. The longest delays were about 3 hours 29 minutes in one report and about 9 hours 29 minutes in the other. In the second report, the manufacturer found that none of the removed records met the criteria to generate a notification.

    2 reports: 1931259-2026-00012, 1931259-2026-00013

  • One report says a temporary outage at a third-party network provider delayed processing and notifications. Customers were told to watch patients manually while notifications were delayed. The manufacturer said all delayed items were later processed.

    Report: 1931259-2026-00018

  • One report describes a system-wide delay of about 157 minutes affecting all customers. The manufacturer said a server failure went undetected, which slowed the response, and the faulty server was removed from the system.

    Report: 1931259-2026-00011

  • One report says an old copy of a data-collection program kept running alongside its replacement, flooding the system with data. Delays reached about 4 hours 6 minutes at one hospital, and a second hospital was affected while the system was busy fixing the problem. The duplicate program was turned off to resolve it.

    Report: 1931259-2026-00010

Written by AI from the narratives of the 10 newest reports that have one, received Nov 10, 2025 to Sep 23, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
1in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Watch SAK in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get SAK every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in SAK. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.