Product codes

FDA product code

QYV: Digital Cervical Cytology Slide Imaging System With Artificial Intelligence Algorithm (FDA product code)

Follow QYV: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 864.3900
Review panel
Pathology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
10 in the last 12 months
Median review time
887 daysthe latest 1 decisions
Recall records
11 in the last 12 months
Adverse event reports
5last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code QYV per year, by decision date, 1 since 2024. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
DEN210035 “Genius™ Digital Diagnostics System with the Genius™ Cervical AI algorithm”Hologic, Inc. Jan 31, 2024887 days

Recalls

Recall records for product code QYV per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-1949-2026Class II Hologic, IncIt was identified that certain devices were being operated outside the validated and FDA-cleared display configuration due to user modification of the manufact… Mar 23, 2026

Adverse event reports (MAUDE)

Medical device reports received per year that name product code QYV. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)5

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions5
  • Other or not stated0

Most reported device problems, last 12 months

  1. Inadequate Instructions for Healthcare Professional2
  2. Incorrect, Inadequate or Imprecise Result or Readings1
  3. Therapeutic or Diagnostic Output Failure1

In plain English: what the newest reports describe Written by AI

  • Two reports describe the system showing an image linked to the wrong slide accession ID, which the manufacturer's troubleshooting with cytotechnologists and a field engineer confirmed for both. The manufacturer says this creates a risk of patient sample misidentification and possible misdiagnosis.

    2 reports: 1222780-2026-00393, 1222780-2026-00185

  • Two reports describe a case being read differently on this system than on another system at the same site. One report says the case was read as negative on the device and positive on the imager system. The customer's investigation is still ongoing, and one of these reports says there was no delay in diagnosis.

    2 reports: 1222780-2026-00332, 1222780-2026-00397

  • A letter from the manufacturer warns that the monitor's display can behave differently if users change its factory display or calibration settings. The manufacturer says such changes are not permitted, and asks customers to complete a response form so it can carry out a field correction.

    Report: MW5186395

Written by AI from the narratives of the 5 newest reports that have one, received Apr 6, 2026 to Jul 6, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
9in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Watch QYV in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get QYV every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in QYV. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.