Product codes

FDA product code

QWU: Prosthesis, Eyelid Spacer/Graft, Polymer (FDA product code)

Follow QWU: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 886.3130
Review panel
Ophthalmic
Premarket route
510(k) exempt
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
10 in the last 12 months
Median review time
245 daysthe latest 1 decisions
Recall records
30 in the last 12 months
Adverse event reports
0last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code QWU per year, by decision date, 1 since 2023. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K223074 CorNeat EverPatchCorneat Vision , Ltd. Jun 2, 2023245 days

Recalls

Recall records for product code QWU per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20241
20252
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0039-2026Class II CORNEAT VISION, LTD.Reviewed complaints have identified that conjunctival wound dehiscence may result in early exposure of the surgical patch. Aug 18, 2025
Z-0040-2026Class II CORNEAT VISION, LTD.Reviewed complaints have identified that conjunctival wound dehiscence may result in early exposure of the surgical patch. Aug 18, 2025
Z-2537-2025Class II CORNEAT VISION, LTD.Retroactive; Due to complaints, labeling correction for permanent tissue-integrating surgical matrices to include prevention and management of would dehiscence. Oct 16, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code QWU. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20210
20220
20230
202427
20256
2026 (so far)0

Last 12 months by event type

No reports received in the last 12 months.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
2in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Product codes classified under the same regulation.

Watch QWU in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get QWU every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in QWU. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.