Product codes

FDA product code

QRA: Virtual Reality Behavioral Therapy Device For Pain Relief (FDA product code)

Follow QRA: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 890.5800
Review panel
Physical Medicine
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
61 in the last 12 months
Median review time
151 daysthe latest 6 decisions
Recall records
10 in the last 12 months
Adverse event reports
0last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code QRA per year, by decision date, 6 since 2021. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20211
20220
20232
20241
20251
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K254004 VRNTCognifisense, Inc. Apr 10, 2026116 days
K251519 RelieVRx (Pico G3)Appliedvr Aug 13, 202589 days
K243417 RelieVRxAppliedvr Dec 4, 202430 days
K230814 VRNTCognifisense, Inc. Oct 31, 2023221 days
K230825 Smileyscope System (Therapy Mode)Smileyscope Holding, Inc. Sep 25, 2023185 days
DEN210014 EaseVRxAppliedvr, Inc. Nov 16, 2021231 days

Recalls

Recall records for product code QRA per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20231
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2044-2023Class II AppliedvrThere is the potential for the program software to malfunction which will not allow it to move forward to the next session. Feb 27, 2023

Adverse event reports (MAUDE)

Medical device reports received per year that name product code QRA. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

No adverse event reports received in the last ten years.

Last 12 months by event type

No reports received in the last 12 months.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
17in the FDA’s Global Unique Device Identification Database
Establishment listings
3registered establishments that list this product code

Watch QRA in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get QRA every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in QRA. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.