Product codes

FDA product code

QLX: Nucleic Acid Amplification Test For The Quantitation Of Epstein-Barr Virus (Ebv) Dna (FDA product code)

Follow QLX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 866.3183
Review panel
Microbiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
40 in the last 12 months
Median review time
204 daysthe latest 4 decisions
Recall records
00 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code QLX per year, by decision date, 4 since 2020. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20201
20211
20221
20230
20240
20251
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K243489 Alinity m EBV (09N43-095)Abbott Molecular, Inc. Jul 28, 2025258 days
K212778 Alinity m EBV AMP Kit (List No. 09N43-095), Alinity m EBV CTRL Kit (List No. 09N43-085), Alinity m EBV CAL Kit (List No. 09N43-075)Abbott Molecular, Inc. Jul 15, 2022317 days
K203220 cobas BKVRoche Molecular Systems, Inc. Jan 29, 202188 days
DEN200015 cobas EBV, cobas EBV/BKV Control Kit, cobas Buffer Negative Control KitRoche Molecular Systems, Inc. Jul 30, 2020150 days

Recalls

Recall records for product code QLX per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code QLX. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20210
20220
20231
20244
20252
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. False Negative Result1

In plain English: what the newest reports describe Written by AI

  • Two reports describe a person who got a positive result from a home finger-prick test and then ordered a lab quantitative test to measure virus copies in the blood. The lab reported a negative result with no copy count one day later. The person says they paid out of pocket and the test was never run, and they questioned why consumers cannot run their own tests.

    2 reports: 23692525, MW5175381

  • One report says EBV results were consistently higher on the newer platform than on the older M2000 system after a lab switched. In two patients, one sample read about 5.45 log IU/mL on the new system versus 3.12 log IU/mL on the old one. The customer's repeat testing showed similar repeatability within each platform, and the report ends before the findings are complete.

    Report: 3005248192-2024-00079

  • One report describes a low-level sample tested three times, giving about 700 IU/mL once and about 3,000 IU/mL twice. Staff suspected the first sample had some blood cell breakdown (hemolysis) because it looked red. The report says no patient harm was noted and the third result was the one released.

    Report: 3005248192-2024-00055

  • One report describes a sample that gave 224 IU/mL on first testing and 79,600 IU/mL on repeat, which the doctor said fit the clinical picture better. Another sample from the same patient gave 16,218 IU/mL, and an earlier sample gave 16,982 IU/mL. The report calls the results questionable and does not state a cause.

    Report: 2243471-2024-03266

Written by AI from the narratives of the 7 newest reports that have one, received Feb 27, 2023 to Jan 20, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
8in the FDA’s Global Unique Device Identification Database
Establishment listings
10registered establishments that list this product code

Product codes classified under the same regulation.

Watch QLX in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get QLX every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in QLX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.