QLT: Covid-19 Multi-Analyte Respiratory Panel Nucleic Acid Devices (FDA product code)

Follow QLT: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Not classified
Regulation
None listed
Review panel
Microbiology
Premarket route
Not stated
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
00 in the last 12 months
Median review time
Not availablethe latest 0 decisions
Recall records
110 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code QLT per year, by decision date. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

No decisions on record for this product code.

Recalls

Recall records for product code QLT per year, by the date the recall began. Each recalled product is one record; these 11 records belong to 8 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20201
20212
20224
20233
20241
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0043-2025Class II Luminex Molecular Diagnostics IncRespiratory pathogen panel may report an elevated rate (7.6% predicted probability of occurrence) of non-specific hMPV target (human Metapneumovirus) results,… Sep 5, 2024
Z-2245-2023Class II Qiagen GmbHIdentified a decreased performance reliability rate, Run abortions could cause delayed diagnosis since sample testing would have to be repeated May 19, 2023
Z-2246-2023Class II Qiagen GmbHIdentified a decreased performance reliability rate, Run abortions could cause delayed diagnosis since sample testing would have to be repeated May 19, 2023
Z-1683-2023Class II Qiagen Sciences LLCFaulty cartridges in the lot could result in false test results. Apr 28, 2023
Z-1104-2023Class II Roche Molecular Systems, Inc.The firm received customer complaints regarding false negative Influenza A (Flu A) results and late Flu A Target Ct values. A false negative influenza A result… Dec 21, 2022

Adverse event reports (MAUDE)

Medical device reports received per year that name product code QLT. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
2021392
2022900
2023283
2024115
20252
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. False Negative Result1

In plain English: what the newest reports describe Written by AI

  • In three reports, this test disagreed with another test run on the same sample. Flu A or B was negative here but positive on another system in one report, positive here but negative on another method in another, and a negative was contradicted by a laboratory molecular test.

    3 reports: 2243471-2025-00783, 2243471-2024-03558, 3017638293-2026-00009

  • In a report, the manufacturer's investigation found no product problem and attributed a disputed result to a weak positive sample near the assay's limit of detection, the lowest amount the test can reliably pick up. Repeat tests on such samples can give inconsistent results.

    Report: 2243471-2025-01283

  • In a report, the test returned an invalid result, meaning it gave no usable answer. The user said customer support would not replace the test until a later date because the manufacturer was upgrading its systems.

    Report: MW5158047

  • In a report, a control swab known to be positive gave a negative result for flu B. The manufacturer's note says the device had not been returned, so the reported result could not be checked; no harm was alleged and no patient samples were involved.

    Report: 3016608638-2024-00004

Written by AI from the narratives of the 6 newest reports that have one, received May 6, 2024 to Apr 17, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
3in the FDA’s Global Unique Device Identification Database
Establishment listings
9registered establishments that list this product code

Watch QLT in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get QLT every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in QLT. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.