Product codes

FDA product code

QJS: Interoperable Automated Glycemic Controller, Insulin Suspend (FDA product code)

Follow QJS: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 862.1356
Review panel
Clinical Chemistry
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
10 in the last 12 months
Median review time
73 daysthe latest 1 decisions
Recall records
00 in the last 12 months
Adverse event reports
391last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code QJS per year, by decision date, 1 since 2020. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20201
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K193483 Basal-IQ TechnologyTandem Diabetes Care, Inc. Feb 28, 202073 days

Recalls

Recall records for product code QJS per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code QJS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20212
20221
20230
20240
20250
2026 (so far)391

Last 12 months by event type

  • Deaths0
  • Injuries209
  • Malfunctions182
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem157
  2. Unexpected Therapeutic Results98
  3. Wireless Communication Problem30
  4. Excess Flow or Over-Infusion25
  5. Insufficient Flow or Under Infusion25
  6. Obstruction of Flow13

In plain English: what the newest reports describe Written by AI

  • Low blood sugar (hypoglycemia) was reported in several reports, with values between 43 and 60 mg/dL where given, and was treated with glucose or carbohydrates. One report describes sweating and weakness, and another describes bleeding.

    7 reports: 2032227-2026-264755, 2032227-2026-264839, 2032227-2026-264873, 2032227-2026-262288, 2032227-2026-262213, 2032227-2026-262209, 2032227-2026-264823

  • High blood sugar (hyperglycemia) was reported in several reports, with values from 400 to 500 mg/dL, treated with insulin or hospital care. In one report, a review found the pump's clock time was incorrect.

    5 reports: 2032227-2026-264756, 2032227-2026-264843, 2032227-2026-264861, 2032227-2026-263023, 2032227-2026-262278

  • In three reports the sensor glucose reading (the value from the sensor worn under the skin) differed from the blood glucose check by more than the acceptable range. Examples include 113 mg/dL sensor against 43 mg/dL blood, and 50 mg/dL sensor against 100 mg/dL blood.

    3 reports: 2032227-2026-264823, 2032227-2026-262213, 2032227-2026-262264

  • Over-delivery of insulin, meaning more insulin than intended, was reported in two reports, and both also describe low blood sugar. Neither report gives a cause, and in one the blood glucose value was not known.

    2 reports: 2032227-2026-263877, 2032227-2026-262209

  • The pump screen froze in two reports, with the buttons not responding and the clock not advancing. In one, replacing the battery did not fix the screen, and the customer said they would stop using the pump.

    2 reports: 2032227-2026-263055, 2032227-2026-263091

Written by AI from the narratives of the 18 newest reports that have one, received Oct 27, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
14in the FDA’s Global Unique Device Identification Database
Establishment listings
6registered establishments that list this product code

Product codes classified under the same regulation.

Watch QJS in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get QJS every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in QJS. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.