FDA product code

QDA: Electrocardiograph Software For Over-The-Counter Use (FDA product code)

Follow QDA: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.2345
Review panel
Cardiovascular
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
90 in the last 12 months
Median review time
122 daysthe latest 9 decisions
Recall records
00 in the last 12 months
Adverse event reports
9last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code QDA per year, by decision date, 9 since 2018. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20181
20190
20203
20210
20220
20232
20241
20252
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K240795 Withings ECG AppWithings Jun 15, 2025450 days
K243236 WHOOP ECG (electrocardiogram) Feature (1.0)Whoop., Inc. Apr 4, 2025176 days
K240909 Samsung ECG App v 1.3 (ECG)Samsung Electronics Co., Ltd. Aug 2, 2024122 days
K230292 Samsung ECG Monitor Application with Irregular Heart Rhythm NotificationSamsung Electronics Co., Ltd. May 2, 202389 days
K221774 Garmin ECG AppGarmin International, Inc. Jan 12, 2023205 days
K201525 ECG AppApple, Inc. Oct 8, 2020122 days
K200948 Fitbit ECG AppFitbit, Inc. Sep 11, 2020156 days
K201168 ECG Monitor AppSamsung Electronics Co., Ltd. Aug 4, 202095 days
DEN180044 ECG AppApple, Inc. Sep 11, 201828 days

Recalls

Recall records for product code QDA per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code QDA. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20214
20223
20235
202414
20255
2026 (so far)6

Last 12 months by event type

  • Deaths0
  • Injuries2
  • Malfunctions4
  • Other or not stated3

Most reported device problems, last 12 months

  1. Defective Device2
  2. Device Sensing Problem2
  3. Adverse Event Without Identified Device or Use Problem1
  4. Data Problem1
  5. False Positive Result1
  6. Incorrect, Inadequate or Imprecise Result or Readings1

In plain English: what the newest reports describe Written by AI

  • Several reports say smartwatch blood sugar readings were far from a regular glucose meter, sometimes too high and sometimes too low. One reader delayed medication after a 112 mg/dL reading, then a meter showed 302 mg/dL and they felt thirsty and dizzy.

    4 reports: MW6002207, MW5159584, MW5159548, MW5152224

  • Four reports describe skin problems under the band, including redness, itching, and peeling like a sunburn. One reader described a red mark left after tightening the band as instructed. Reporters suspect the band or its material, but the reports do not confirm a cause.

    4 reports: MW5187513, MW5177669, MW5162805, MW5184337

  • Reports say some of these products are advertised to test blood pressure, blood sugar, and heart rhythm, which one reporter believes they cannot do accurately. One reader says a blood pressure reading was off, and another fears people will rely on the watch as a diagnostic tool.

    3 reports: MW5163039, MW5162024, MW5158448

  • Heart rate readings sometimes disagreed sharply with other checks. One reader saw a heart rate double from 75 to 130 beats per minute while a manual check showed 75. Another found the watch and its linked app showing very different ranges, and a reinstall changed nothing.

    2 reports: MW5186921, MW5180944

  • One reader with a sinus rhythm problem says the ECG app often reports atrial fibrillation, an irregular heartbeat, when it is not present. The reader estimates the app is wrong 80 to 90 percent of the time.

    Report: MW5164056

Written by AI from the narratives of the 18 newest reports that have one, received Feb 29, 2024 to Sep 24, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
28in the FDA’s Global Unique Device Identification Database
Establishment listings
34registered establishments that list this product code

Watch QDA in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get QDA every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in QDA. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.