Product codes

FDA product code

PSY: Whole Slide Imaging System (FDA product code)

Follow PSY: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 864.3700
Review panel
Pathology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
234 in the last 12 months
Median review time
237 daysthe latest 23 decisions
Recall records
21 in the last 12 months
Adverse event reports
5last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code PSY per year, by decision date, 23 since 2017. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20180
20192
20200
20212
20221
20231
20249
20252
2026 (so far)4

Latest decisions

NumberDevice and applicantDecision and review time
K253554 Aperio GT 450 DX; Aperio GT 180 DXLeica Biosystems Imaging, Inc. Aug 7, 2026266 days
K260964 NanoZoomer S540MD Slide Scanner SystemHamamatsu Photonics K.K. Jul 22, 2026121 days
K251952 VirasightVirasoft Corporation Jul 17, 2026387 days
K253606 NanoZoomer S20MD Slide scanner system; NanoZoomer S360MD Slide scanner systemHamamatsu Photonics K.K. Jul 15, 2026239 days
K243871 Philips IntelliSite Pathology Solution 5.1Philips Medical Systems Nederland B.V. Mar 6, 202579 days
K241717 E1000 Dx Digital Pathology SolutionShandon Diagnostics Limited Feb 28, 2025259 days
K242783 Roche Digital Pathology DxVentana Medical Systems, Inc. Dec 17, 202492 days
K242848 Philips IntelliSite Pathology Solution 5.1Philips Medical Systems Nederland B.V. Dec 10, 202481 days
K241871 Philips IntelliSite Pathology SolutionPhilips Medical Systems Nederland B.V. Dec 2, 2024158 days
K233204 Philips IntelliSite Pathology Solution 5.1Philips Medical Systems Nederland B.V. Jun 24, 2024270 days

Recalls

Recall records for product code PSY per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20231
20240
20250
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-2913-2026Class II Ventana Medical Systems, Inc.Due to complaints received for the Image Management System regarding image/metadata discrepancy with the Viewer window Apr 20, 2026
Z-2280-2023Class II Hamamatsu CorporationIf the wrong barcode information is recorded in the NDPi file, a pathologist may refer to the whole slide image (WSI) of a different patient. Jun 6, 2023

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PSY. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20191
20201
20210
20220
20231
20240
20250
2026 (so far)5

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions5
  • Other or not stated0

Most reported device problems, last 12 months

  1. Application Program Problem3
  2. Application Program Freezes or Fails to Launch1
  3. Computer Operating System Problem1
  4. Insufficient Device Problem Information1
  5. Program or Algorithm Execution Failure1

In plain English: what the newest reports describe Written by AI

  • Two reports describe a viewer problem in NavifyPath Digital Pathology where a slide image is shown with the wrong label or from the wrong specimen. One report says the cause is specimen names with leading zeros mixed with names of 100 or higher, which shifts the slide position in the viewer. The manufacturer says the images match correctly in the data management section.

    2 reports: 2028492-2026-01688, 2028492-2026-01689

  • One report describes a software problem in the NavifyPath digital pathology system where the viewer shows the wrong patient information: surnames, dates of birth, ages and gender are assigned incorrectly, or display as placeholder text like XXXX, which forces staff to check the lab information system to match patients to cases. The first report says this causes delays.

    Report: 2028492-2026-02791

  • One report describes a problem where the line measurement annotation on the image does not match the image's visual scale, sometimes. Pathologists use these measurements for things like melanoma thickness and margins, which are part of a primary diagnosis. The customer says no patient diagnosis has been affected.

    Report: 2028492-2026-02306

  • One report describes a scanner that crashed while a slide was being processed, breaking the slide. The manufacturer's technical specialist reported that only one slide broke, that it affected one patient, and that enough spare slides were made from the same sample, so testing was not hindered.

    Report: 1419341-2026-00008

  • One report describes a scanner in the United Kingdom where incorrectly printed barcode labels caused two slides to be saved with only a date and time as the file name. The manufacturer says the scan's reference data showed information from the previous slide, and it chose to file a report out of caution because a similar US scanner exists.

    Report: 0009614683-2023-00001

Written by AI from the narratives of the 8 newest reports that have one, received May 9, 2019 to Jul 10, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
21in the FDA’s Global Unique Device Identification Database
Establishment listings
25registered establishments that list this product code

Watch PSY in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PSY every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PSY. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.