Product codes

FDA product code

PRL: Iliac Covered Stent, Arterial (FDA product code)

Follow PRL: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class III
Regulation
None listed
Review panel
Cardiovascular
Premarket route
PMA
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
PMA decisions
773 original PMAs, the rest supplements
Median review time
28 daysthe latest 25 decisions
Recall records
60 in the last 12 months
Adverse event reports
592last 12 months, 3 deaths

PMA decisions

Original PMAs and supplements for product code PRL per year, by decision date, 77 since 2017. Review time is the days from receipt to decision.

All of them in the FDA’s PMA database

PMA decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20177
201814
20199
20206
20215
20226
20239
20248
20259
2026 (so far)4

Latest decisions

NumberDevice and applicantDecision and review time
P160021 S051 GORE® VIABAHN® VBX Balloon Expandable EndoprosthesisW. L. Gore & Associates, Inc. Oct 8, 2026244 days
P160021 S052 GORE® VIABAHN® VBX Balloon Expandable EndoprosthesisW. L. Gore & Associates, Inc. Jun 16, 202625 days
P120003 S007 iCast Covered Stent SystemAtrium Medical Corp. May 13, 2026518 days
P160021 S050 GORE® VIABAHN® VBX Balloon Expandable EndoprosthesisW. L. Gore & Associates, Inc. Feb 5, 20269 days
P120003 S009 iCast Covered Stent SystemAtrium Medical Corp. Dec 22, 2025189 days
P160021 S048 GORE® VIABAHN® VBX Balloon Expandable EndoprosthesisW. L. Gore & Associates, Inc. Nov 24, 202594 days
P160021 S049 GORE® VIABAHN® VBX Balloon Expandable EndoprosthesisW. L. Gore & Associates, Inc. Oct 17, 202528 days
P160024 S014 LifeStream™ Balloon Expandable Vascular Covered StentBard Peripheral Vascular, Inc. Sep 29, 20257 days
P120003 S011 iCast Covered Stent SystemAtrium Medical Corp. Sep 12, 202530 days
P120003 S010 iCast Covered Stent SystemAtrium Medical Corp. Aug 20, 202529 days

Recalls

Recall records for product code PRL per year, by the date the recall began. Each recalled product is one record; these 6 records belong to 5 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20191
20200
20211
20220
20231
20243
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0024-2025Class II Atrium Medical CorporationThere is an error in the Unique Device Identifier (UDI) printed on the product's distribution label. Sep 9, 2024
Z-2945-2024Class II W L Gore & Associates, Inc.Due to packaging defects, sterility assurance and heparin activity may be compromised. Jul 1, 2024
Z-2946-2024Class II W L Gore & Associates, Inc.Due to packaging defects, sterility assurance and heparin activity may be compromised. Jul 1, 2024
Z-0291-2024Class II Atrium Medical CorporationBalloon-to-catheter weld failure that may cause loss of balloon pressure during stent deployment. Sep 21, 2023
Z-0077-2022Class II W L Gore & Associates, Inc.Incorrect labeling, specifically, expandable endoprosthesis labeled as 8 mm x 59mm x 135 cm, however may contain a 9mm x 29 mm x 135 cm device. Sep 7, 2021

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PRL. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201791
2018102
201999
2020184
2021235
2022287
2023303
2024448
2025477
2026 (so far)550

Last 12 months by event type

  • Deaths3
  • Injuries264
  • Malfunctions323
  • Other or not stated2

Most reported device problems, last 12 months

  1. Device Dislodged or Dislocated245
  2. Complete Blockage45
  3. Device Stenosis41
  4. Material Deformation40
  5. Device Endoleak38
  6. Adverse Event Without Identified Device or Use Problem33

In plain English: what the newest reports describe Written by AI

  • Four reports describe kidney-feeding side branches of the stent grafts becoming blocked, with one kidney losing function in at least one case. Doctors suggested different causes: stopping blood-thinning medicine, and a stent pressed against the aorta wall by a large aneurysm and narrow aorta.

    4 reports: 2017233-2026-08248, 2017233-2026-08237, 2017233-2026-08218, 2017233-2026-08217

  • Two reports describe the stent coming loose from the balloon catheter, the thin tube that carries it. One stent could not pass through the sheath, the introducer tube, and was not used. In the other, the stent came off during removal and was retrieved through a groin incision.

    2 reports: 9616666-2026-00260, 3011175548-2026-000014

  • Two reports describe two stent grafts in a patient's right iliac artery, a large pelvic artery, becoming blocked, while blood still reached the leg through side routes. The facility blamed an unspecified device issue and a new diagnosis of heparin-induced thrombocytopenia, a clotting disorder caused by heparin.

    2 reports: 2017233-2026-08227, 2017233-2026-08228

  • Two reports describe the delivery system, the tube used to position the device, separating or breaking during removal. In one, the device detached twice and surgeons cut the groin to retrieve it. In the other, the shaft broke under significant friction in winding, tortuous anatomy.

    2 reports: 2017233-2026-08233, 2017233-2026-08210

  • One report describes a balloon that would not inflate past about 2 atmospheres, a low pressure, so the stent graft did not expand. The physician said the device was handled properly and the balloon may have malfunctioned. A different stent was placed and the patient tolerated the procedure.

    Report: 2017233-2026-08273

Written by AI from the narratives of the 15 newest reports that have one, received Oct 20, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
230in the FDA’s Global Unique Device Identification Database
Establishment listings
13registered establishments that list this product code

Watch PRL in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PRL every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PRL. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.