PMC: Scalp Cooling System (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 878.4360
- Review panel
- General and Plastic Surgery
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 70 in the last 12 months
- Median review time
- 126 daysthe latest 7 decisions
- Recall records
- 10 in the last 12 months
- Adverse event reports
- 3last 12 months, 1 death
510(k) and De Novo decisions
Decisions for product code PMC per year, by decision date, 7 since 2015. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 2 |
| 2018 | 1 |
| 2019 | 1 |
| 2020 | 0 |
| 2021 | 1 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 1 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K252289 | Eva Scalp Cooling SystemStemtech Medical Devices Private Limited | Nov 25, 2025125 days |
| K211526 | Portable Scalp Cooling SystemCooler Heads Care, Inc. | Oct 21, 2021157 days |
| K191166 | DigniCap DeltaDignitana, Inc. | Jun 26, 201956 days |
| K173032 | Paxman Scalp CoolerPaxman Coolers Limited | Jun 7, 2018252 days |
| K170871 | DigniCap Scalp Cooling SystemDignitana AB | Jul 3, 2017102 days |
| K163484 | Paxman Scalp CoolerPaxman Coolers Limited | Apr 17, 2017126 days |
| DEN150010 | Dignitana AB DigniCap SystemDignitana AB | Dec 8, 2015277 days |
Recalls
Recall records for product code PMC per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 1 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0825-2022Class II | Dignitana, Inc.Instructions for Use (IFUs) updated to include use of a headband is now recommended for all patients and instructions for the application of the headband. Addi… | Nov 5, 2021 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code PMC. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 8 |
| 2021 | 3 |
| 2022 | 4 |
| 2023 | 17 |
| 2024 | 15 |
| 2025 | 9 |
| 2026 (so far) | 3 |
Last 12 months by event type
- Deaths1
- Injuries0
- Malfunctions1
- Other or not stated1
Most reported device problems, last 12 months
- Adverse Event Without Identified Device or Use Problem1
- Component Missing1
In plain English: what the newest reports describe Written by AI
Several reports describe burns on the scalp, forehead, temple, neck or hairline area during scalp cooling. One report notes the burn occurred where the headband was not placed correctly, and another notes the patient did not use a headband.
9 reports: 3012146457-2025-00007, 3012146457-2025-00005, 3012146457-2025-00006, 3012146457-2025-00003, 3012146457-2025-00002, 3012146457-2025-00001, 3012146457-2024-00010, 3012146457-2024-00008, 3012146457-2024-00006
Coolant leaked or sprayed from the cooling cap or tubing in two reports. In one, coolant ran from a patient's cap and stung her eyes, and in the other it splashed from where the cap tail joins the pump tubing, and the patient reported the cap felt cold.
2 reports: 20224052, 19527237
In one report, a bulge in the tubing burst open as a nurse was about to attach it, spraying coolant into her eyes and mouth. She rinsed at an eyewash station and was taken to the emergency department for evaluation. The patient's clothing was cleaned, and the room was cleaned according to the safety data sheet.
Report: 24952916
In one report, the cooling unit's power plug emitted a spark and began to smoke after a burning smell was noticed during treatment. Staff unplugged it, and the patient and staff were not harmed. The unit was sent to the manufacturer for inspection.
Report: MW5171344
In one report, a unit malfunctioned when being plugged in, leading to a large spill on the floor. No further details are given.
Report: 23356261
Written by AI from the narratives of the 16 newest reports that have one, received Jun 13, 2024 to Oct 26, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 67in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 9registered establishments that list this product code
Watch PMC in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get PMC every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PMC. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:PMCRetrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:PMCRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:PMC · count decision_dateRetrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:PMCRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:PMC · count event_date_initiatedRetrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:PMC · count res_event_numberRetrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0825-2022")Retrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:PMC AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:PMC AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:PMC AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:PMCRetrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:PMCRetrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:878.4360Retrieved Nov 29, 2026, 1:08 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil