Product codes

FDA product code

PLR: Spinal Vertebral Body Replacement Device - Cervical (FDA product code)

Follow PLR: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 888.3060
Review panel
Orthopedic
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
191 in the last 12 months
Median review time
155 daysthe latest 19 decisions
Recall records
00 in the last 12 months
Adverse event reports
3last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code PLR per year, by decision date, 19 since 2015. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20183
20195
20202
20210
20222
20232
20240
20251
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K252822 Atlas Spine HiRISE™ Expandable Cervical-p Corpectomy ImplantAtlas Spine, Inc. Jul 15, 2026314 days
K252560 Atlas Spine HiRISE™ Expandable Cervical Corpectomy SystemAtlas Spine, Inc. Nov 10, 202589 days
K232481 RIGEL™ 3DR Anterior Cervical Corpectomy SystemMiRus, LLC Oct 13, 202358 days
K221542 Galileo Vertebral Body Replacement DeviceBright Spine Jan 13, 2023231 days
K212126 MediExpand Cervical Expandable VBR SystemCmf Medicon Surgical, Inc. Apr 4, 2022271 days
K211320 CAPRI Corpectomy Cage SystemK2m, Inc. Feb 24, 2022300 days
K192145 Galileo Vertebral Body Replacement DeviceBright Spine Apr 21, 2020257 days
K193412 NEXXT MATRIXX SystemNexxt Spine, LLC Feb 24, 202077 days
K190284 Bengal Stackable Cage SystemMedos International SARL Dec 20, 2019312 days
K190426 ALTA Anterior Cervical Corpectomy SystemAstura Medical, LLC Oct 24, 2019244 days

Recalls

Recall records for product code PLR per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PLR. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20181
20191
20202
20214
20221
20230
20240
20251
2026 (so far)3

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions2
  • Other or not stated0

Most reported device problems, last 12 months

  1. Material Twisted/Bent1
  2. Mechanical Jam1
  3. Migration1

In plain English: what the newest reports describe Written by AI

  • Three reports describe the spinal cage (a spacer that holds the bone apart) moving out of position after surgery, found at follow-up X-rays at one, two or several weeks or months. Revision surgery was needed to reposition or remove it in each case.

    3 reports: 2027467-2026-00148, 2027467-2025-00094, 2031966-2022-00099

  • Three reports describe cages or inserter tools that would not expand or adjust properly during surgery. In one, the inserter was stripped, and in another, the cage's moving part broke off. Surgeons left the cages in place in these cases, and no harm was reported.

    3 reports: 2027467-2026-00029, 1030489-2020-01814, 1030489-2021-00116

  • Two reports from a clinical study describe patients with breathing trouble and swallowing problems after spine surgery. One patient was placed on a breathing machine in intensive care, and the swallowing problem remained and was referred to an ear, nose and throat specialist. The reports do not state whether the device caused these problems.

    2 reports: 3004774118-2021-00154, 3004774118-2021-00155

  • Two reports describe nonunion, meaning the bone did not fuse, and pseudoarthrosis, a false joint where bone failed to heal together. One patient needed extra fixation hardware added, and a published study described pseudoarthrosis in some patients along with cage sinking and migration that needed revision surgery.

    2 reports: 3004774118-2021-00151, MW5086113

  • One report describes parts of the implant not being kept in their designated spots in the inner packaging. The implant was too loose on the insertion tool and came out when placed, so a larger size was used and the bone had to be further shaped, delaying surgery about 40 minutes.

    Report: 9610612-2018-00028

Written by AI from the narratives of the 11 newest reports that have one, received Jan 31, 2018 to Jul 15, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
3,985in the FDA’s Global Unique Device Identification Database
Establishment listings
113registered establishments that list this product code

Watch PLR in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PLR every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PLR. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.