Product codes

FDA product code

PII: Candida Species Nucleic Acid Detection System (FDA product code)

Follow PII: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 866.3960
Review panel
Microbiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
30 in the last 12 months
Median review time
118 daysthe latest 3 decisions
Recall records
10 in the last 12 months

510(k) and De Novo decisions

Decisions for product code PII per year, by decision date, 3 since 2014. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K234063 T2Candida 1.1 PanelT2biosystems, Inc. Sep 13, 2024266 days
K173536 T2Candida 1.1 PanelT2biosystems, Inc. Dec 12, 201727 days
DEN140019 T2CANDIDA AND T2DX INSTRUMENTT2biosystems, Inc. Sep 22, 2014118 days

Recalls

Recall records for product code PII per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2795-2016Class II T2 Biosystems IncElevated levels of invalid results. Jul 7, 2016

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PII. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

This section didn’t load from openFDA. It’s retried within the hour.

Last 12 months by event type

This section didn’t load from openFDA. It’s retried within the hour.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
7in the FDA’s Global Unique Device Identification Database
Establishment listings
3registered establishments that list this product code

Product codes classified under the same regulation.

Watch PII in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PII every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PII. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.