FDA product code
PER: Automated Pipetting, Diluting And Specimen Processing Workstations For Flow Cytometric Analysis (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 862.2750
- Review panel
- Clinical Chemistry
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 30 in the last 12 months
- Median review time
- 87 daysthe latest 3 decisions
- Recall records
- 101 in the last 12 months
- Adverse event reports
- 2last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code PER per year, by decision date, 3 since 2005. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K131301 | BD FACS SAMPLE PREP ASSISTANT IIIBecton, Dickinson & CO | Aug 2, 201387 days |
| K130253 | TQ-PREP WORKSTATION, PREPPLUS 2 WORKSTATIONBeckman Coulter, Inc. | Jul 15, 2013164 days |
| K050191 | MODIFICATION TO BD FACSCANTO SYSTEM WITH BD FACSCANTO CLINICAL SOFTWAREBecton, Dickinson & CO | Feb 22, 200526 days |
Recalls
Recall records for product code PER per year, by the date the recall began. Each recalled product is one record; these 10 records belong to 7 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 2 |
| 2018 | 0 |
| 2019 | 3 |
| 2020 | 1 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 1 |
| 2025 | 3 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1235-2026Class II | Beckman Coulter, Inc.Sample preparation system designed to automate staining, lysing, cell washing has a software error that causes samples to be dispensed close to or touching tub… | Dec 23, 2025 |
| Z-0412-2026Class II | Beckman Coulter, Inc.Automated pipetting, diluting and specimen processing workstations for flow cytometric analysis device instructions for use list incorrect dead volumes: Casset… | Sep 8, 2025 |
| Z-1113-2025Class II | Sysmex America, Inc.Sysmex was made aware of a report of false results due to carry-over caused by the sporadic omission of the probe wash step during antibody pipetting on the PS… | Jan 6, 2025 |
| Z-0009-2025Class II | Becton, Dickinson and Company, BD Bio SciencesSample preparation system with software may cause: 1) Multidispense feature enabled with 2-tube assay: Specimen volume dispensed into tube1 at least 3% higher… | Aug 12, 2024 |
| Z-2687-2020Class II | Sysmex America, Inc.Insufficient amount of antibody without an error message or alarm | Jul 6, 2020 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code PER. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 37 |
| 2021 | 54 |
| 2022 | 63 |
| 2023 | 11 |
| 2024 | 3 |
| 2025 | 6 |
| 2026 (so far) | 1 |
Last 12 months by event type
- Deaths0
- Injuries1
- Malfunctions1
- Other or not stated0
Most reported device problems, last 12 months
- Adverse Event Without Identified Device or Use Problem1
- Contamination1
In plain English: what the newest reports describe Written by AI
Several reports describe the instrument giving erroneous or abnormal results, with some results reported to clinicians or used for patient treatment; one report says patients were treated based on erroneous results. Reports say the cause was not always identified, and some say no delay or harm occurred.
8 reports: 2916837-2023-00173, 2916837-2023-00141, 2916837-2023-00109, 2916837-2023-00219, 3027394506-2025-00023, 2916837-2023-00066, 1061932-2023-00103, 2916837-2024-00024
Several reports describe carryover, where material from one patient sample mixes into the next, and a report says cellular carryover was seen in a PBS tube. The manufacturer's software report links this to omitted probe washing and possible antibody carryover, which may lead to incorrect marker readings.
5 reports: 3027394506-2025-00041, 2916837-2024-00001, 1000515253-2025-00004, 1000515253-2025-00002, 3027394506-2026-00002
A few reports describe liquid leaking or overflowing from the wash tower or waste line, including biohazardous fluid not contained within the instrument. One report describes an overflow at a wash station where a filter was suspected of being blocked.
4 reports: 2916837-2023-00056, 2916837-2023-00030, 2916837-2023-00040, 2916837-2023-00048
Some reports describe the sample preparation unit failing to add blood or reagent to tubes, so samples were not properly prepared. Affected samples were discarded and re-prepared on another unit, and one report says the probe was replaced without fixing the problem.
3 reports: 2916837-2024-00024, 1061932-2023-00103, 2916837-2023-00109
The manufacturer reported a software defect in the sample preparation system where the probe wash step can be skipped, in versions 1.5 and 1.6. The manufacturer states no incorrect treatment, serious injury or death has been reported due to this problem.
2 reports: 1000515253-2025-00004, 1000515253-2025-00002
Written by AI from the narratives of the 19 newest reports that have one, received Feb 8, 2023 to Feb 6, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 11in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 21registered establishments that list this product code
Other codes under 21 CFR 862.2750
Product codes classified under the same regulation.
Watch PER in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get PER every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PER. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:PERRetrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:PERRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:PER · count decision_dateRetrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:PERRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:PER · count event_date_initiatedRetrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:PER · count res_event_numberRetrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1235-2026" "Z-0412-2026" "Z-1113-2025" "Z-0009-2025" "Z-2687-2020")Retrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:PER AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:PER AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:PER AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:PERRetrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:PERRetrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:862.2750Retrieved Nov 29, 2026, 12:56 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil