FDA product code

PER: Automated Pipetting, Diluting And Specimen Processing Workstations For Flow Cytometric Analysis (FDA product code)

Follow PER: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 862.2750
Review panel
Clinical Chemistry
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
30 in the last 12 months
Median review time
87 daysthe latest 3 decisions
Recall records
101 in the last 12 months
Adverse event reports
2last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code PER per year, by decision date, 3 since 2005. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K131301 BD FACS SAMPLE PREP ASSISTANT IIIBecton, Dickinson & CO Aug 2, 201387 days
K130253 TQ-PREP WORKSTATION, PREPPLUS 2 WORKSTATIONBeckman Coulter, Inc. Jul 15, 2013164 days
K050191 MODIFICATION TO BD FACSCANTO SYSTEM WITH BD FACSCANTO CLINICAL SOFTWAREBecton, Dickinson & CO Feb 22, 200526 days

Recalls

Recall records for product code PER per year, by the date the recall began. Each recalled product is one record; these 10 records belong to 7 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20172
20180
20193
20201
20210
20220
20230
20241
20253
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1235-2026Class II Beckman Coulter, Inc.Sample preparation system designed to automate staining, lysing, cell washing has a software error that causes samples to be dispensed close to or touching tub… Dec 23, 2025
Z-0412-2026Class II Beckman Coulter, Inc.Automated pipetting, diluting and specimen processing workstations for flow cytometric analysis device instructions for use list incorrect dead volumes: Casset… Sep 8, 2025
Z-1113-2025Class II Sysmex America, Inc.Sysmex was made aware of a report of false results due to carry-over caused by the sporadic omission of the probe wash step during antibody pipetting on the PS… Jan 6, 2025
Z-0009-2025Class II Becton, Dickinson and Company, BD Bio SciencesSample preparation system with software may cause: 1) Multidispense feature enabled with 2-tube assay: Specimen volume dispensed into tube1 at least 3% higher… Aug 12, 2024
Z-2687-2020Class II Sysmex America, Inc.Insufficient amount of antibody without an error message or alarm Jul 6, 2020

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PER. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
202037
202154
202263
202311
20243
20256
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem1
  2. Contamination1

In plain English: what the newest reports describe Written by AI

  • Several reports describe the instrument giving erroneous or abnormal results, with some results reported to clinicians or used for patient treatment; one report says patients were treated based on erroneous results. Reports say the cause was not always identified, and some say no delay or harm occurred.

    8 reports: 2916837-2023-00173, 2916837-2023-00141, 2916837-2023-00109, 2916837-2023-00219, 3027394506-2025-00023, 2916837-2023-00066, 1061932-2023-00103, 2916837-2024-00024

  • Several reports describe carryover, where material from one patient sample mixes into the next, and a report says cellular carryover was seen in a PBS tube. The manufacturer's software report links this to omitted probe washing and possible antibody carryover, which may lead to incorrect marker readings.

    5 reports: 3027394506-2025-00041, 2916837-2024-00001, 1000515253-2025-00004, 1000515253-2025-00002, 3027394506-2026-00002

  • A few reports describe liquid leaking or overflowing from the wash tower or waste line, including biohazardous fluid not contained within the instrument. One report describes an overflow at a wash station where a filter was suspected of being blocked.

    4 reports: 2916837-2023-00056, 2916837-2023-00030, 2916837-2023-00040, 2916837-2023-00048

  • Some reports describe the sample preparation unit failing to add blood or reagent to tubes, so samples were not properly prepared. Affected samples were discarded and re-prepared on another unit, and one report says the probe was replaced without fixing the problem.

    3 reports: 2916837-2024-00024, 1061932-2023-00103, 2916837-2023-00109

  • The manufacturer reported a software defect in the sample preparation system where the probe wash step can be skipped, in versions 1.5 and 1.6. The manufacturer states no incorrect treatment, serious injury or death has been reported due to this problem.

    2 reports: 1000515253-2025-00004, 1000515253-2025-00002

Written by AI from the narratives of the 19 newest reports that have one, received Feb 8, 2023 to Feb 6, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
11in the FDA’s Global Unique Device Identification Database
Establishment listings
21registered establishments that list this product code

Watch PER in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PER every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PER. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.