Product codes

FDA product code

PAD: Chest Drainage Kit (FDA product code)

Follow PAD: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 880.6740
Review panel
General Hospital
Premarket route
Not stated
Implant
No
Life-sustaining or supporting
No
GMP exempt
Yes
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
00 in the last 12 months
Median review time
Not availablethe latest 0 decisions
Recall records
204 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code PAD per year, by decision date. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

No decisions on record for this product code.

Recalls

Recall records for product code PAD per year, by the date the recall began. Each recalled product is one record; these 20 records belong to 8 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20241
20251
2026 (so far)4

Latest recalls

Recall and classFirm and reasonBegan
Z-2427-2026Class II Medline Industries, LPKits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for applica… Apr 27, 2026
Z-2382-2026Class I ARROW INTERNATIONAL, LLCLidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality is… Apr 21, 2026
Z-1412-2026Class II Medline Industries, LPMedline has identified issues related to calibration of the equipment used to sterilize and package the devices. All products were exposed to the validated ste… Jan 7, 2026
Z-2106-2026Class II Medline Industries, LPMedline has identified issues related to calibration of the equipment used to sterilize and package the devices. All products were exposed to the validated ste… Jan 7, 2026
Z-1609-2025Class II MEDLINE INDUSTRIES, LP - NorthfieldThere is a potential for open/weak seals on purchased breather pouches used for packaging of select sterile convenience kits. Mar 3, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PAD. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20171
20183
20192
20202
20211
20225
20231
20240
20251
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions0
  • Other or not stated0

Most reported device problems, last 12 months

  1. Device Misassembled During Manufacturing /Shipping1

In plain English: what the newest reports describe Written by AI

  • Several reports describe the drain's connectors, tubing or clamps failing, such as a crack in a connector, a snapped catheter port, or a clamp jaw breaking off. In some cases this let air or fluid leak or caused a lung collapse (pneumothorax).

    6 reports: 3012307300-2023-03443, 3012307300-2022-18168, 3012307300-2022-05603, MW5103925, 9948616, 3012307300-2019-05948

  • Several reports describe the tubing being bent, crimped or kinked, or the drainage not sucking properly. In these cases the tube would not stay open or drainage could not be measured accurately, so staff changed to another unit.

    5 reports: 9611018-2018-00302, 9611018-2018-00301, 9611018-2018-00300, 21950304, MW5098409

  • Two reports describe a guidewire that could not pass through the pleural catheter, bending the guidewire so the catheter could not be placed into the chest.

    2 reports: 3012307300-2022-03495, 3012307300-2022-03532

  • One report describes a plastic guide that would not let a metal guide pass through it during an emergency on a patient in cardiac arrest. This delayed care, and a drain was placed with a different lot number. The patient survived.

    Report: 3012307300-2019-06247

  • One report describes the tray meant to hold the access tip coming loose inside its pouch, so the adapter was not attached. A picture was provided.

    Report: 3002808026-2026-00014

Written by AI from the narratives of the 18 newest reports that have one, received Jul 18, 2013 to Sep 9, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
8in the FDA’s Global Unique Device Identification Database
Establishment listings
23registered establishments that list this product code

Watch PAD in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PAD every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PAD. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.