Product codes

FDA product code

OOK: Dermal Cooling Pack/Vacuum/Massager (FDA product code)

Follow OOK: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4340
Review panel
General and Plastic Surgery
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
140 in the last 12 months
Median review time
113 daysthe latest 14 decisions
Recall records
60 in the last 12 months
Adverse event reports
635last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code OOK per year, by decision date, 14 since 2010. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20181
20191
20201
20211
20220
20230
20241
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K233732 CoolSculpting Elite SystemZeltiq Aesthetics, Inc. (Acquired by Allergan Aesthetics Sep 12, 2024296 days
K212707 CoolSculpting Elite SystemZeltiq Aesthetics, Inc. Nov 5, 202171 days
K193566 ZELTIQ CoolSculpting SystemZeltiq Aesthetics, Inc. Jan 21, 202029 days
K183514 ZELTIQ CoolSculpting SystemZeltiq Aesthetics, Inc. Jan 14, 201927 days
K181740 ZELTIQ CoolSculpting SystemZeltiq Aesthetics, Inc. Aug 29, 201858 days
K172144 CoolSculpting SystemZeltiq Aesthetics Nov 1, 2017107 days
K171069 ZELTIQ CoolSculpting SystemZeltiq Aesthetics, Inc. Jul 7, 201788 days
K162050 ZELTIQ CoolSculpting SystemZeltiq Aesthetics, Inc. Nov 21, 2016119 days
K160259 ZELTIQ CoolSculpting SystemZeltiq Aesthetics, Inc. Mar 23, 201651 days
K151179 ZELTIQ CoolSculpting SystemZeltiq Aesthetics, Inc. Sep 22, 2015141 days

Recalls

Recall records for product code OOK per year, by the date the recall began. Each recalled product is one record; these 6 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20211
20225
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1346-2022Class II Zeltiq Aesthetics, IncExecuting a voluntary discontinuation and removal of parallel plate applicators due to an increase complaint rate for adverse event Paradoxical Hyperplasia (HP… Jun 9, 2022
Z-1347-2022Class II Zeltiq Aesthetics, IncExecuting a voluntary discontinuation and removal of parallel plate applicators due to an increase complaint rate for adverse event Paradoxical Hyperplasia (HP… Jun 9, 2022
Z-1348-2022Class II Zeltiq Aesthetics, IncExecuting a voluntary discontinuation and removal of parallel plate applicators due to an increase complaint rate for adverse event Paradoxical Hyperplasia (HP… Jun 9, 2022
Z-1349-2022Class II Zeltiq Aesthetics, IncExecuting a voluntary discontinuation and removal of parallel plate applicators due to an increase complaint rate for adverse event Paradoxical Hyperplasia (HP… Jun 9, 2022
Z-1350-2022Class II Zeltiq Aesthetics, IncExecuting a voluntary discontinuation and removal of parallel plate applicators due to an increase complaint rate for adverse event Paradoxical Hyperplasia (HP… Jun 9, 2022

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OOK. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20179
201810
201949
202018
20211,161
20221,978
20235,499
20241,277
2025916
2026 (so far)561

Last 12 months by event type

  • Deaths0
  • Injuries631
  • Malfunctions4
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem619
  2. Temperature Problem3
  3. Appropriate Device Problem Term/Code Not Available2
  4. Excessive Cooling2
  5. Off-Label Use2
  6. Device Dislodged or Dislocated1

In plain English: what the newest reports describe Written by AI

  • Many reports describe paradoxical hyperplasia, a condition where treated fat appears to grow instead of shrink. The treated area was described as enlarged and firmer, and in some reports as hard or painful when pinched.

    18 reports: 3007215625-2026-00539, 3007215625-2026-00540, 3007215625-2026-00541, 3007215625-2026-00542, 3007215625-2026-00547, 3007215625-2026-00548, 3007215625-2026-00549, 3007215625-2026-00550, 3007215625-2026-00551, 3007215625-2026-00552, 3007215625-2026-00553, 3007215625-2026-00554, 3007215625-2026-00555, 3007215625-2026-00556, 3007215625-2026-00558, 3007215625-2026-00559, 3007215625-2026-00560, 3007215625-2026-00561

  • Several reports do not name the treatment, the date or the applicator used, so they are hard to link to a specific device setup. The reports were filed by clinicians or customers who gave only a general account.

    3 reports: 3007215625-2026-00541, 3007215625-2026-00548, 3007215625-2026-00554

  • A report describes persistent swelling, tenderness and a firm, bloated abdomen about three to four weeks after abdominal treatment. The report does not say that this condition was paradoxical hyperplasia.

    Report: 3007215625-2026-00557

  • A report describes blistering, bruising, inflammation and fluid on the back after treatment of the left upper flank. The device logged a thermal, or overheating, event with 26 seconds left and ended with an error code, and the clinician prescribed creams.

    Report: 3007215625-2026-00543

  • One report says the patient had a facelift to remove the paradoxical hyperplasia after a treatment under the chin. The patient said the area looked like a bullfrog, and the change appeared less than one month after treatment.

    Report: 3007215625-2026-00551

Written by AI from the narratives of the 20 newest reports that have one, received Oct 19, 2026 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
155in the FDA’s Global Unique Device Identification Database
Establishment listings
52registered establishments that list this product code

Product codes classified under the same regulation.

Watch OOK in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OOK every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OOK. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.