Product codes

FDA product code

OOG: Knee Arthroplasty Implantation System (FDA product code)

Follow OOG: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 888.3560
Review panel
Orthopedic
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
20 in the last 12 months
Median review time
209 daysthe latest 2 decisions
Recall records
30 in the last 12 months
Adverse event reports
28last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code OOG per year, by decision date, 2 since 2021. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20211
20220
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K230850 United Orthopedic Knee Patient Specific InstrumentationEnhatch, Inc. Dec 20, 2023267 days
K203421 Triathlon AS-1Conformis, Inc. Apr 19, 2021150 days

Recalls

Recall records for product code OOG per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0138-2016Class II ConforMIS, Inc.May contain small amounts of ethylene glycol residue Aug 31, 2015
Z-0139-2016Class II ConforMIS, Inc.May contain small amounts of ethylene glycol residue Aug 31, 2015
Z-0140-2016Class II ConforMIS, Inc.May contain small amounts of ethylene glycol residue Aug 31, 2015

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OOG. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201710
20182
201915
20208
20214
202218
202323
202472
202534
2026 (so far)28

Last 12 months by event type

  • Deaths0
  • Injuries24
  • Malfunctions4
  • Other or not stated0

Most reported device problems, last 12 months

  1. Patient-Device Incompatibility24
  2. Application Program Problem: Parameter Calculation Error1
  3. Fracture1
  4. Loosening of Implant Not Related to Bone-Ingrowth1
  5. Patient Device Interaction Problem1

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
6,881in the FDA’s Global Unique Device Identification Database
Establishment listings
161registered establishments that list this product code

Watch OOG in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OOG every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OOG. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.