Product codes

FDA product code

OKE: Port Introducer Kit (FDA product code)

Follow OKE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 880.5965
Review panel
General Hospital
Premarket route
Not stated
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
00 in the last 12 months
Median review time
Not availablethe latest 0 decisions
Recall records
112 in the last 12 months
Adverse event reports
0last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code OKE per year, by decision date. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

No decisions on record for this product code.

Recalls

Recall records for product code OKE per year, by the date the recall began. Each recalled product is one record; these 11 records belong to 8 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20221
20232
20240
20252
2026 (so far)2

Latest recalls

Recall and classFirm and reasonBegan
Z-0219-2027Class I Cardinal Health 200, LLCKits contain infusion sets which were recalled for performance issues. Sep 24, 2026
Z-2819-2026Class II Windstone Medical Packaging, Inc.Windstone Medical Packaging recalled specific items and lots of AMS convenience kits containing Elevaris Lidocaine HCl injection USP. Elevaris Medical Devices… Jun 17, 2026
Z-0186-2026Class II American Contract Systems Inc.Identified products were re-gassed (sterilized more than once) after a nonconformance occurred during the initial Ethylene Oxide (EO) gas injection process. Th… Sep 4, 2025
Z-1343-2025Class II American Contract Systems IncACS is unable to confirm product sterilization assurance requirements were met. Possible loss or lack of functionality may lead to delay or prolonged treatment. Feb 6, 2025
Z-0826-2024Class II American Contract Systems, Inc.During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There… Nov 29, 2023

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OKE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20184
20190
20201
20210
20220
20230
20241
20250
2026 (so far)0

Last 12 months by event type

No reports received in the last 12 months.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
1,829in the FDA’s Global Unique Device Identification Database
Establishment listings
22registered establishments that list this product code

Watch OKE in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OKE every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OKE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.