FDA product code
OIP: Radiology-Diagnostic Kit (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 892.1680
- Review panel
- Radiology
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 00 in the last 12 months
- Median review time
- Not availablethe latest 0 decisions
- Recall records
- 50 in the last 12 months
- Adverse event reports
- 1last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code OIP per year, by decision date. Review time is the days from receipt to decision.
No decisions on record for this product code.
Recalls
Recall records for product code OIP per year, by the date the recall began. Each recalled product is one record; these 5 records belong to 4 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 2 |
| 2022 | 1 |
| 2023 | 1 |
| 2024 | 0 |
| 2025 | 1 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0182-2026Class II | American Contract Systems Inc.Identified products were re-gassed (sterilized more than once) after a nonconformance occurred during the initial Ethylene Oxide (EO) gas injection process. Th… | Sep 4, 2025 |
| Z-0092-2024Class II | Cardinal Health 200, LLCPacks contain recalled components (equipment drapes, table cover, and surgical room turnover (SRT) kits). | Aug 16, 2023 |
| Z-1038-2022Class II | American Contract Systems, Inc.Product was sterilized with a higher than specification EO concentration. | Mar 22, 2022 |
| Z-0254-2022Class II | ROi CPS LLCPovidone-Iodine swabstick manufactured by PDI, Inc. recalled due to Out of Specifications was used as a component in some of the ROI CPS, LLC products. | Aug 10, 2021 |
| Z-0255-2022Class II | ROi CPS LLCPovidone-Iodine swabstick manufactured by PDI, Inc. recalled due to Out of Specifications was used as a component in some of the ROI CPS, LLC products. | Aug 10, 2021 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code OIP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 0 |
| 2018 | 1 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 2 |
| 2022 | 0 |
| 2023 | 1 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Last 12 months by event type
- Deaths0
- Injuries0
- Malfunctions1
- Other or not stated0
Most reported device problems, last 12 months
- Defective Component1
- Fluid/Blood Leak1
- Incomplete or Inadequate Connection1
In plain English: what the newest reports describe Written by AI
In one report, contrast dye leaked from the joint between the tubing and the access needle during a myelogram, which is a spinal imaging scan, interfering with delivery of the dye. The radiologist reportedly said this had happened before with the same kit type. The reporter stated the tubing was defective and could create an unsafe condition for patients.
Report: MW6001473
A report says an ultrasound probe cover was found to be defective before use. The report gives no further details about the effect on any patient.
Report: MW5099217
In one report, a staff member noticed a black fiber on the cap of a collection vial in a sterile lumbar puncture tray before using it. She did not use that vial to collect fluid from the patient.
Report: 18334381
In one report, a blue particle was found inside the basket of a stent retriever, a wire device used to remove clots, after a stroke procedure. The particle was not seen during earlier uses of the device. The team believed it was lint from towels in the kit. The report does not state the patient's outcome.
Report: MW5075521
In one report, a female inpatient had extravasation, meaning fluid leaked out of a vessel into surrounding tissue, and the drug was reported as ineffective during a diagnostic procedure. The report does not say what the procedure was or why these events occurred.
Report: 2411512-2021-00002
Written by AI from the narratives of the 5 newest reports that have one, received Feb 23, 2018 to Aug 25, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 1,193in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 21registered establishments that list this product code
Other codes under 21 CFR 892.1680
Product codes classified under the same regulation.
Watch OIP in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get OIP every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OIP. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:OIPRetrieved Nov 29, 2026, 12:22 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:OIPRetrieved Nov 29, 2026, 5:43 PM UTC.
- device/510k · search product_code:OIP · count decision_dateRetrieved Nov 29, 2026, 12:22 AM UTC.
- device/recall · search product_code:OIPRetrieved Nov 29, 2026, 5:43 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:OIP · count event_date_initiatedRetrieved Nov 29, 2026, 12:22 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:OIP · count res_event_numberRetrieved Nov 29, 2026, 12:22 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0182-2026" "Z-0092-2024" "Z-1038-2022" "Z-0254-2022" "Z-0255-2022")Retrieved Nov 29, 2026, 5:43 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OIP AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 5:43 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OIP AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 5:43 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OIP AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 12:22 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:OIPRetrieved Nov 29, 2026, 12:22 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:OIPRetrieved Nov 29, 2026, 12:22 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:892.1680Retrieved Nov 28, 2026, 11:21 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil