Product codes

FDA product code

OGG: Humidifier Nebulizer Kit (FDA product code)

Follow OGG: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.5450
Review panel
Anesthesiology
Premarket route
Not stated
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
00 in the last 12 months
Median review time
Not availablethe latest 0 decisions
Recall records
21 in the last 12 months
Adverse event reports
119last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code OGG per year, by decision date. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

No decisions on record for this product code.

Recalls

Recall records for product code OGG per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-2993-2026Class II Medline Industries, LPNeonatal and infant heated wire breathing circuits may experience sporadic failure. The heated wire connector (pigtail) at the humidifier may exhibit discolora… Jul 13, 2026
Z-0505-2015Class II Teleflex MedicalPossibility that the nebulizer adaptor packaging may have open or weak seals which may affect the sterility of the adaptor. Sep 3, 2014

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OGG. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201791
2018117
2019109
202092
202162
202214
20239
20248
202511
2026 (so far)119

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions118
  • Other or not stated0

Most reported device problems, last 12 months

  1. Gas/Air Leak27
  2. Overheating of Device24
  3. Fluid/Blood Leak17
  4. Melted16
  5. Crack13
  6. Circuit Failure6

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
205in the FDA’s Global Unique Device Identification Database
Establishment listings
31registered establishments that list this product code

Product codes classified under the same regulation.

Watch OGG in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OGG every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OGG. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.