Product codes

FDA product code

NRF: Material, Quality Control, Semen Analysis (FDA product code)

Follow NRF: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 864.8625
Review panel
Hematology
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
30 in the last 12 months
Median review time
25 daysthe latest 3 decisions
Recall records
10 in the last 12 months

510(k) and De Novo decisions

Decisions for product code NRF per year, by decision date, 3 since 2004. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K042750 QC-BEADSBioscreen, Inc. Oct 29, 200425 days
K041600 QWIKCHECK-BEADSMedical Electronics Systems , Ltd. Jul 27, 200443 days
K041240 SEMEN ANALYSIS QUALITY CONTROL, ASSAYED AND UNASSAYEDFertility Solutions, Inc. Jun 2, 200422 days

Recalls

Recall records for product code NRF per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20251
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1262-2026Class II Changchun Wancheng Bio-Electron Co., Ltd.Test strips and other tests including for near-patient testing, that require a 510(k) were distributed before they could be legally marketed to U.S. customers;… Nov 22, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code NRF. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

This section didn’t load from openFDA. It’s retried within the hour.

Last 12 months by event type

This section didn’t load from openFDA. It’s retried within the hour.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
33in the FDA’s Global Unique Device Identification Database
Establishment listings
12registered establishments that list this product code

Watch NRF in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get NRF every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in NRF. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.