FDA product code
NIO: Stent, Iliac (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class III
- Regulation
- None listed
- Review panel
- Cardiovascular
- Premarket route
- PMA
- Implant
- Yes
- Life-sustaining or supporting
- Yes
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- PMA decisions
- 38815 original PMAs, the rest supplements
- Median review time
- 27 daysthe latest 25 decisions
- Recall records
- 70 in the last 12 months
- Adverse event reports
- 506last 12 months, 8 deaths
PMA decisions
Original PMAs and supplements for product code NIO per year, by decision date, 388 since 1996. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 18 |
| 2018 | 16 |
| 2019 | 22 |
| 2020 | 21 |
| 2021 | 12 |
| 2022 | 15 |
| 2023 | 16 |
| 2024 | 12 |
| 2025 | 14 |
| 2026 (so far) | 17 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| P110028 S027 | ABSOLUTE PRO VASCULAR SELF-EXPANDING STENT SYSTEMAbbott Vascular, Inc. | Nov 13, 202630 days |
| P050017 S027 | Zilver 635 Vascular Stent, Zilver 518 Vascular StentCook Ireland, Ltd. | Nov 6, 202629 days |
| P030045 S011 | Visi-Pro™ balloon-Expandable peripheral stent systemMedtronic Vascular, Inc. | Oct 16, 202629 days |
| P020036 S061 | S.M.A.R.T. ® CONTROL® Nitinol Stent SystemCordis US Corporation | Oct 15, 202630 days |
| P140030 S025 | Astron Peripheral Self-Expanding Nitinol Stent SystemBiotronik AG | Sep 11, 202637 days |
| P110035 S079 | Epic™ Vascular Self-Expanding Stent SystemBoston Scientific Corp | Aug 21, 202628 days |
| P110035 S078 | Epic™ Vascular Self-Expanding Stent SystemBoston Scientific Corp | Aug 6, 202624 days |
| P140002 S032 | MISAGO(TM) RX Self-expanding Peripheral StentTerumo Medical Corporation | Jul 16, 2026199 days |
| P140030 S024 | Astron Peripheral Self-Expanding Nitinol Stent SystemBiotronik AG | Jun 22, 202612 days |
| P090003 S057 | Express™ LD ILIAC Premounted Stent SystemBoston Scientific Corporation | May 6, 202628 days |
Recalls
Recall records for product code NIO per year, by the date the recall began. Each recalled product is one record; these 7 records belong to 6 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 1 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 2 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1510-2025Class II | Cordis US Corpproduct mix-up; Vascular stent labeled as one size but contains a different size. | Mar 4, 2025 |
| Z-1511-2025Class II | Cordis US Corpproduct mix-up; Vascular stent labeled as one size but contains a different size. | Mar 4, 2025 |
| Z-0728-2020Class II | Cardinal Health Inc.Cordis has initiated a labeling correction for S.M.A.R.T. and PRECISE stents due to incorrect MRI information on the IFU. The correct classification is "MRI Co… | Nov 14, 2019 |
| Z-0689-2016Class II | Cook Medical IncorporatedManufacturing of the joint between the inner catheter and stylet of the delivery system does not consistently meet specifications, and the joint may separate d… | Dec 22, 2015 |
| Z-1040-2012 | Cordis CorporationCordis Corporation initiated a recall of S.M.A.R.T. CONTROL Nitinol Iliac Stent System due to a potential sterility breach in the pouches. | Jan 31, 2012 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code NIO. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 462 |
| 2018 | 460 |
| 2019 | 416 |
| 2020 | 409 |
| 2021 | 421 |
| 2022 | 352 |
| 2023 | 351 |
| 2024 | 510 |
| 2025 | 650 |
| 2026 (so far) | 455 |
Last 12 months by event type
- Deaths8
- Injuries187
- Malfunctions311
- Other or not stated0
Most reported device problems, last 12 months
- Activation Failure100
- Adverse Event Without Identified Device or Use Problem84
- Device Dislodged or Dislocated80
- Mechanical Jam60
- Difficult to Remove54
- Premature Activation51
In plain English: what the newest reports describe Written by AI
In several reports, the delivery system's deployment mechanism (the thumbwheel or trigger that releases the stent) jammed or failed, so the stent deployed only partly or not at all. In some cases the stent had to be removed and replaced with another device.
5 reports: 2024168-2026-04177, 2024168-2026-04145, 9681442-2026-00257, 9681442-2026-00255, 2024168-2026-04128
In a few reports, a self-expanding stent (a mesh tube that opens inside the artery) broke or fractured while being pulled back or removed, and surgery was needed to open the artery and retrieve the pieces. One report describes a stent fracturing inside the sheath, a tube that holds the device, and needing a second access site to remove it.
2 reports: 2024168-2026-04177, 2024168-2026-04008
In several reports, the stent ruptured or broke while being pushed across the lesion. The reports do not state the outcome for the patient.
2 reports: 2024168-2026-04009, 2024168-2026-04010
In one report, a stent separated at its proximal end during deployment, and the loose piece moved into the other iliac artery. The physician placed another stent to lock the loose piece against the vessel wall.
Report: 2024168-2026-04146
In one report, the stent became bunched up during a difficult deployment and then blocked blood flow, and the patient's limb was amputated. The manufacturer's and reporter's account links the bunching to the deployment difficulty, which the report describes as a delivery system failure after the device snagged on a guidewire.
Report: 2124215-2026-55630
Written by AI from the narratives of the 20 newest reports that have one, received Oct 11, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 781in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 60registered establishments that list this product code
Watch NIO in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get NIO every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in NIO. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:NIORetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:NIORetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:NIO · count decision_dateRetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:NIO · count pma_numberRetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:NIORetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:NIO · count event_date_initiatedRetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:NIO · count res_event_numberRetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1510-2025" "Z-1511-2025" "Z-0728-2020" "Z-0689-2016" "Z-1040-2012")Retrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:NIO AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:NIO AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:NIO AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:NIORetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:NIORetrieved Nov 29, 2026, 10:43 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil