NFJ: System, Image Management, Ophthalmic (FDA product code)

Follow NFJ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 892.2050
Review panel
Ophthalmic
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
532 in the last 12 months
Median review time
116 daysthe latest 25 decisions
Recall records
140 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code NFJ per year, by decision date, 53 since 2002. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20175
20187
20192
20205
20212
20223
20234
20242
20250
2026 (so far)2

Latest decisions

NumberDevice and applicantDecision and review time
K260694 ZEISS CLINIC 360Carl Zeiss Meditec, AG Jul 17, 2026136 days
K253893 Harmony Referral System with Harmony OCT Viewer (Octave)Topcon Healthcare Solutions EMEA Oy Jun 4, 2026182 days
K234076 iCare ALTIUS CWCentervue S.P.A. Aug 22, 2024245 days
K232828 IMAGEnet6 Ophthalmic Data SystemTopcon Corporation Mar 1, 2024170 days
K232944 CALLISTO eyeCarl Zeiss Meditec, AG Dec 21, 202392 days
K232555 HarmonyTopcon Healthcare Solutions Nov 20, 202389 days
K231676 CALLISTO eyeCarl Zeiss Meditec, AG Aug 28, 202380 days
K232088 Altris IMSAltris, Inc. Jul 31, 202318 days
K220929 ExcelsiorMerit Cro, Inc. Oct 31, 2022214 days
K213527 FORUMCarl Zeiss Meditec, AG Aug 15, 2022284 days

Recalls

Recall records for product code NFJ per year, by the date the recall began. Each recalled product is one record; these 14 records belong to 13 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20172
20180
20191
20202
20210
20221
20230
20241
20251
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2673-2025Class II MedicalCommunications GmbHPotential that the measured value may be smaller than the actual area. Sep 9, 2025
Z-0362-2025Class II Topcon Medical Systems, Inc.The overlay of visual field test locations on a probability map, as presented in IMAGEnet 6 in the so-called "Hood Report", is not appropriate as it can imply… Sep 17, 2024
Z-0826-2022Class II Diagnos IncRetinal analysis system software has some features, based on artificial intelligence, that potentially lack appropriate market approval, so it is recommended t… Jan 11, 2022
Z-0952-2021Class II Topcon Medical Systems, Inc.Harmony RS integrations with Topcon equipment, TRC NW-400 and the Signal Camera, allowed user input of non-unique patient IDs that caused multiple patient reco… Dec 18, 2020
Z-0636-2021Class II Kowa Optimed IncIt has been determined that the software distributed with the retinal camera may delete patient information. Specifically, if multiple IDs are delated at the s… Nov 3, 2020

Adverse event reports (MAUDE)

Medical device reports received per year that name product code NFJ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20174
20180
20192
20200
20211
20222
20230
20240
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions0
  • Other or not stated0

Most reported device problems, last 12 months

  1. Image Orientation Incorrect1

In plain English: what the newest reports describe Written by AI

  • Three reports describe patient records or eye scans appearing under the wrong patient's name. In one, the display switched to a previous patient's information. The manufacturer said no harm occurred in one report, while another report of a wrong name described a possible misdiagnosis, with the outcome unknown. The manufacturer could not reproduce that issue.

    3 reports: 3013986459-2022-00001, 2183926-2019-00006, 9614661-2019-00001

  • Three reports describe eye images being lost or unusable. One says images were permanently unavailable, so the patient had to return on another day for retesting. Another describes a faulty workstation that could delay treatment or cause data loss, and the third describes a fragmented hard drive where images could not be recovered. No patient injury was reported in these reports.

    3 reports: 2183926-2017-00163, 2183926-2016-00413, 2183926-2016-00044

  • A toric lens, which corrects astigmatism and must sit at a precise angle, was placed off target in two reports. In one, the markerless alignment feature failed and the lens was implanted 90 degrees off the planned angle, leaving about 6 diopters of astigmatism and requiring a follow-up surgery. In the other, the video image was shown upside down, so the lens went in at 78 degrees instead of 102 degrees.

    2 reports: 9615010-2017-00012, 9615010-2026-00017

  • Two reports describe the wrong lens power being chosen because the calculation used another patient's measurements. One lens was about 5 diopters off target and was replaced. In the other, the error was noticed only when results were unexpected, and the report says a second operation could have been needed but did not occur.

    2 reports: 8030392-2021-00002, 1000307022-2017-00001

  • A surgeon reported that the microscope lost its automatic focus and zoom controls during cataract surgery, and that a restart changed settings. A capsule tear occurred, and the surgery was completed with a different microscope and a lens placed in the sulcus, the groove behind the iris. The surgeon thought the tear was linked to the changed settings.

    Report: 9615010-2022-00003

Written by AI from the narratives of the 11 newest reports that have one, received Apr 7, 2016 to Sep 4, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
104in the FDA’s Global Unique Device Identification Database
Establishment listings
76registered establishments that list this product code

Watch NFJ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get NFJ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in NFJ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.