FDA product code
NFJ: System, Image Management, Ophthalmic (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 892.2050
- Review panel
- Ophthalmic
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 532 in the last 12 months
- Median review time
- 116 daysthe latest 25 decisions
- Recall records
- 140 in the last 12 months
- Adverse event reports
- 1last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code NFJ per year, by decision date, 53 since 2002. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 5 |
| 2018 | 7 |
| 2019 | 2 |
| 2020 | 5 |
| 2021 | 2 |
| 2022 | 3 |
| 2023 | 4 |
| 2024 | 2 |
| 2025 | 0 |
| 2026 (so far) | 2 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260694 | ZEISS CLINIC 360Carl Zeiss Meditec, AG | Jul 17, 2026136 days |
| K253893 | Harmony Referral System with Harmony OCT Viewer (Octave)Topcon Healthcare Solutions EMEA Oy | Jun 4, 2026182 days |
| K234076 | iCare ALTIUS CWCentervue S.P.A. | Aug 22, 2024245 days |
| K232828 | IMAGEnet6 Ophthalmic Data SystemTopcon Corporation | Mar 1, 2024170 days |
| K232944 | CALLISTO eyeCarl Zeiss Meditec, AG | Dec 21, 202392 days |
| K232555 | HarmonyTopcon Healthcare Solutions | Nov 20, 202389 days |
| K231676 | CALLISTO eyeCarl Zeiss Meditec, AG | Aug 28, 202380 days |
| K232088 | Altris IMSAltris, Inc. | Jul 31, 202318 days |
| K220929 | ExcelsiorMerit Cro, Inc. | Oct 31, 2022214 days |
| K213527 | FORUMCarl Zeiss Meditec, AG | Aug 15, 2022284 days |
Recalls
Recall records for product code NFJ per year, by the date the recall began. Each recalled product is one record; these 14 records belong to 13 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 2 |
| 2018 | 0 |
| 2019 | 1 |
| 2020 | 2 |
| 2021 | 0 |
| 2022 | 1 |
| 2023 | 0 |
| 2024 | 1 |
| 2025 | 1 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-2673-2025Class II | MedicalCommunications GmbHPotential that the measured value may be smaller than the actual area. | Sep 9, 2025 |
| Z-0362-2025Class II | Topcon Medical Systems, Inc.The overlay of visual field test locations on a probability map, as presented in IMAGEnet 6 in the so-called "Hood Report", is not appropriate as it can imply… | Sep 17, 2024 |
| Z-0826-2022Class II | Diagnos IncRetinal analysis system software has some features, based on artificial intelligence, that potentially lack appropriate market approval, so it is recommended t… | Jan 11, 2022 |
| Z-0952-2021Class II | Topcon Medical Systems, Inc.Harmony RS integrations with Topcon equipment, TRC NW-400 and the Signal Camera, allowed user input of non-unique patient IDs that caused multiple patient reco… | Dec 18, 2020 |
| Z-0636-2021Class II | Kowa Optimed IncIt has been determined that the software distributed with the retinal camera may delete patient information. Specifically, if multiple IDs are delated at the s… | Nov 3, 2020 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code NFJ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 4 |
| 2018 | 0 |
| 2019 | 2 |
| 2020 | 0 |
| 2021 | 1 |
| 2022 | 2 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Last 12 months by event type
- Deaths0
- Injuries1
- Malfunctions0
- Other or not stated0
Most reported device problems, last 12 months
- Image Orientation Incorrect1
In plain English: what the newest reports describe Written by AI
Three reports describe patient records or eye scans appearing under the wrong patient's name. In one, the display switched to a previous patient's information. The manufacturer said no harm occurred in one report, while another report of a wrong name described a possible misdiagnosis, with the outcome unknown. The manufacturer could not reproduce that issue.
3 reports: 3013986459-2022-00001, 2183926-2019-00006, 9614661-2019-00001
Three reports describe eye images being lost or unusable. One says images were permanently unavailable, so the patient had to return on another day for retesting. Another describes a faulty workstation that could delay treatment or cause data loss, and the third describes a fragmented hard drive where images could not be recovered. No patient injury was reported in these reports.
3 reports: 2183926-2017-00163, 2183926-2016-00413, 2183926-2016-00044
A toric lens, which corrects astigmatism and must sit at a precise angle, was placed off target in two reports. In one, the markerless alignment feature failed and the lens was implanted 90 degrees off the planned angle, leaving about 6 diopters of astigmatism and requiring a follow-up surgery. In the other, the video image was shown upside down, so the lens went in at 78 degrees instead of 102 degrees.
2 reports: 9615010-2017-00012, 9615010-2026-00017
Two reports describe the wrong lens power being chosen because the calculation used another patient's measurements. One lens was about 5 diopters off target and was replaced. In the other, the error was noticed only when results were unexpected, and the report says a second operation could have been needed but did not occur.
2 reports: 8030392-2021-00002, 1000307022-2017-00001
A surgeon reported that the microscope lost its automatic focus and zoom controls during cataract surgery, and that a restart changed settings. A capsule tear occurred, and the surgery was completed with a different microscope and a lens placed in the sulcus, the groove behind the iris. The surgeon thought the tear was linked to the changed settings.
Report: 9615010-2022-00003
Written by AI from the narratives of the 11 newest reports that have one, received Apr 7, 2016 to Sep 4, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 104in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 76registered establishments that list this product code
Other codes under 21 CFR 892.2050
Product codes classified under the same regulation.
Watch NFJ in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get NFJ every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in NFJ. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:NFJRetrieved Nov 29, 2026, 2:29 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:NFJRetrieved Nov 29, 2026, 5:58 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:NFJ · count decision_dateRetrieved Nov 29, 2026, 2:30 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:NFJRetrieved Nov 29, 2026, 5:58 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:NFJ · count event_date_initiatedRetrieved Nov 29, 2026, 2:29 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:NFJ · count res_event_numberRetrieved Nov 29, 2026, 2:29 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-2673-2025" "Z-0362-2025" "Z-0826-2022" "Z-0952-2021" "Z-0636-2021")Retrieved Nov 29, 2026, 5:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:NFJ AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 5:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:NFJ AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 5:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:NFJ AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 2:30 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:NFJRetrieved Nov 29, 2026, 2:30 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:NFJRetrieved Nov 29, 2026, 2:29 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:892.2050Retrieved Nov 28, 2026, 11:57 PM UTC. FDA data updated Nov 16, 2026.