Product codes

FDA product code

NEW: Suture, Surgical, Absorbable, Polydioxanone (FDA product code)

Follow NEW: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4840
Review panel
General and Plastic Surgery
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
675 in the last 12 months
Median review time
204 daysthe latest 25 decisions
Recall records
400 in the last 12 months
Adverse event reports
2,223last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code NEW per year, by decision date, 67 since 2001. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20183
20194
20203
20211
20221
20231
20243
20256
2026 (so far)5

Latest decisions

NumberDevice and applicantDecision and review time
K254238 MINT MONO SuturesHans Biomed Corporation Sep 18, 2026263 days
K253879 MONOFIX PDOSamyang Holdings Corporation Aug 25, 2026264 days
K261988 Monodek™ (POLYDIOXANONE) Dyed Violet Monofilament Synthetic Absorbable Surgical SutureTeleflex Medical, LLC Jul 9, 202627 days
K252171 Barbed PDO SutureSutura Medical Technology, Inc. Jun 12, 2026337 days
K252047 STRATAFIX™ Symmetric PDS™ Plus Knotless Tissue Control DevicesETHICON, Inc. May 18, 2026322 days
K243897 PDS™ Plus Antibacterial (Polydioxanone) Sterile Synthetic Absorbable Surgical SutureETHICON, Inc. Nov 12, 2025328 days
K251414 Miracu™ Polydioxanone (PDO) Suture and Needle (MONO)Feeltech Co., Ltd. Oct 20, 2025166 days
K250107 V-soft Line™ Barbed Surgical Suture (Various)Feeltech Co., Ltd. Oct 15, 2025273 days
K252644 PINION™ PDO Knotless Suture - Absorbable Poly (P-Dioxanone) Knotless Suture; PINION™ PGA-PCL Knotless Suture - Absorbable Poly (Glycolide-Co-Caprolactone) Knotless SutureM/s. Meril Endo Surgery Private Limited. Sep 23, 202533 days
K250977 Suture-TOOL SystemSuturion AB Apr 28, 202528 days

Recalls

Recall records for product code NEW per year, by the date the recall began. Each recalled product is one record; these 40 records belong to 22 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20186
20197
20200
20210
20222
20233
20241
20255
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2605-2025Class II ETHICON, LLCPotential for barb non-engagement. Aug 15, 2025
Z-1513-2025Class II Ethicon Endo Surgery, LLCIdentified curing issues with the silicone during the needles manufacturing process. Mar 7, 2025
Z-1514-2025Class II Ethicon Endo Surgery, LLCIdentified curing issues with the silicone during the needles manufacturing process. Mar 7, 2025
Z-1515-2025Class II Ethicon Endo Surgery, LLCIdentified curing issues with the silicone during the needles manufacturing process. Mar 7, 2025
Z-1516-2025Class II Ethicon Endo Surgery, LLCIdentified curing issues with the silicone during the needles manufacturing process. Mar 7, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code NEW. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017461
2018900
20191,122
20201,010
20211,466
20221,537
20231,975
20242,114
20252,547
2026 (so far)1,950

Last 12 months by event type

  • Deaths0
  • Injuries429
  • Malfunctions1,791
  • Other or not stated3

Most reported device problems, last 12 months

  1. Break1,106
  2. Material Separation538
  3. Adverse Event Without Identified Device or Use Problem347
  4. Positioning Failure131
  5. Material Integrity Problem38
  6. Failure to Degrade30

In plain English: what the newest reports describe Written by AI

  • In five reports, the needle came loose from the thread while the surgeon was closing a wound or sewing tissue, such as during hysterectomy, uterine closure and a veterinary procedure. Surgeons switched to another suture to finish each case, and no patient harm was reported.

    5 reports: 2210968-2026-10906, 2210968-2026-10805, 2210968-2026-10807, 2210968-2026-10831, 2210968-2026-10891

  • In two reports, the suture broke during use. In one C-section the surgeon used another product to finish. In the other, the suture broke again after a new one was tried, and a third suture was needed to complete the surgery.

    2 reports: 2210968-2026-10941, 2210968-2026-10901

  • In two reports, staff said the barbs (small backward-facing points that grip tissue) on the suture were less prominent and did not hook well. One report said the material also felt different from the earlier version.

    2 reports: 2210968-2026-10673, 2210968-2026-10687

  • In one report, an abdominal suture tore open again shortly after surgery. The patient needed a new procedure and a longer hospital stay.

    Report: 2210968-2026-10963

  • In one report, a barbed suture was left behind after a hysterectomy. At a four-month check, non-absorbable residual suture was found on the cervical stump, with polyps (small growths) clustered around it that bled when touched. The patient was treated with a medicated suppository and was reported stable.

    Report: 2210968-2026-10754

Written by AI from the narratives of the 16 newest reports that have one, received Oct 20, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
3,548in the FDA’s Global Unique Device Identification Database
Establishment listings
186registered establishments that list this product code

Watch NEW in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get NEW every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in NEW. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.