Product codes

FDA product code

MZP: Assay, Hybridization And/Or Nucleic Acid Amplification For Detection Of Hepatitis C Rna,Hepatitis C Virus (FDA product code)

Follow MZP: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 866.3170
Review panel
Microbiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
40 in the last 12 months
Median review time
151 daysthe latest 4 decisions
Recall records
110 in the last 12 months
Adverse event reports
6last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code MZP per year, by decision date, 4 since 2022. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20221
20230
20241
20252
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K252484 cobas HCVRoche Molecular Systems, Inc. Nov 3, 202588 days
K252102 Alinity m HCVAbbott Molecular, Inc. Sep 25, 202584 days
K233352 Aptima HCV Quant Dx AssayHologic, Inc. Jul 24, 2024299 days
K221007 cobas HCVRoche Molecular Systems, Inc. Nov 4, 2022213 days

Recalls

Recall records for product code MZP per year, by the date the recall began. Each recalled product is one record; these 11 records belong to 9 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20214
20221
20231
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0407-2024Class II Abbott Molecular, Inc.Abbott has received reports of an increase in reactive negative controls and false positive results in patient samples when using the Identified Lots of Alinit… Oct 30, 2023
Z-1518-2022Class II Abbott Molecular, Inc.Incorrect optical calibration Jul 19, 2022
Z-0460-2022Class II Abbott Molecular, Inc.There is a potential for abnormal (non-sigmoidal) amplification curves. Dec 6, 2021
Z-0461-2022Class II Abbott Molecular, Inc.There is a software issue associated with the ability to properly complete a Field Service Engineer Maintenance and Diagnostics procedure. Dec 6, 2021
Z-0462-2022Class II Abbott Molecular, Inc.There is a software defect that can cause the Amplification Detection clamp CLEAN position to be set too high. Dec 6, 2021

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MZP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20175
20184
20195
20201
20211
20221
20231
20242
202512
2026 (so far)4

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions6
  • Other or not stated0

Most reported device problems, last 12 months

  1. False Negative Result3
  2. False Positive Result3
  3. Incorrect, Inadequate or Imprecise Result or Readings2
  4. High Test Results1
  5. Improper or Incorrect Procedure or Method1

In plain English: what the newest reports describe Written by AI

  • Several reports describe the same kind of problem: a sample first tests reactive (positive) in a pooled run, then tests non-reactive when repeated, or the reverse. The pooled MPX kit combines samples from several donors before testing, and some reports say the pool result did not match the individual donor result.

    6 reports: 2243471-2026-00548, 2243471-2026-00324, 2243471-2025-05316, 2243471-2025-03357, 2243471-2025-03058, 2243471-2025-03042

  • Some reports describe the test showing a positive result for hepatitis B or C on repeat testing with a very low signal, while antibody (serology) tests on the same patient were negative or borderline. The manufacturer's data in one case showed a sample at the lower limit of detection.

    4 reports: 2243471-2025-04101, 2243471-2025-03534, 2243471-2024-03798, 2243471-2025-03350

  • In a few reports, samples first tested positive for hepatitis C viral load, then tested not detected on repeat, and antibody tests were negative. The results were reported as indeterminate in one case.

    2 reports: 2243471-2024-03155, 2243471-2025-04110

  • A report described a hepatitis B result that was reactive in plasma but non-reactive in serum from the same patient, with weak, irregular amplification curves. The results were interpreted from these weak curves.

    Report: 2243471-2025-03534

  • The manufacturer found that specific lots of the reagent had a reference dye signal outside the expected range, which caused reactive negative controls and false positive patient results. A field action was taken, and the manufacturer reported it.

    Report: 3005248192-2023-00279

Written by AI from the narratives of the 19 newest reports that have one, received Dec 2, 2022 to Aug 10, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
34in the FDA’s Global Unique Device Identification Database
Establishment listings
21registered establishments that list this product code

Product codes classified under the same regulation.

Watch MZP in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MZP every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MZP. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.