Product codes

FDA product code

MXJ: Enzyme Linked Immunosorbent Assay, Herpes Simplex Virus, Hsv-1 (FDA product code)

Follow MXJ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 866.3305
Review panel
Microbiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
200 in the last 12 months
Median review time
150 daysthe latest 20 decisions
Recall records
00 in the last 12 months
Adverse event reports
2last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code MXJ per year, by decision date, 20 since 1999. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20181
20190
20200
20210
20221
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K213987 ARCHITECT HSV-1 IgG, ARCHITECT HSV-1 IgG Calibrator, ARCHITECT HSV-1 IgG ControlsBiokit, S.A. Sep 20, 2023639 days
K220923 Elecsys HSV-1 IgG (08948844160)Roche Diagnostics Oct 12, 2022195 days
K181333 ADVIA Centaur Herpes-1 IgGBiokit, S.A. Aug 23, 201894 days
K162276 SeraQuest Herpes Type 1 Specific IgGQuest International, Inc. Oct 1, 201650 days
K143236 Theranos Herpes Simplex Virus-1 IgG AssayTheranos, Inc. Jul 2, 2015232 days
K131334 HERPES SIMPLEX VIRUS TYPE 1 IGG ELISA TESTGold Standard Diagnostics Feb 28, 2014295 days
K120625 ELECSYS HSV-1 IGG IMMUNOASSAY ELECSYS PRECICONTROL HSVRoche Diagnostics Jul 25, 2012146 days
K120959 BIOPLEX 2200 HSV-1 AND HSV-2 IGG KITBio-Rad Laboratories Jun 22, 201284 days
K103363 ZEUS ELISA HSV GC-I IGG TEST SYSTEMZeus Scientific, Inc. Apr 26, 2011160 days
K090409 BIOPLEX 2200 HSV-1 AND HSV-2 IGG ON THE BIOPLEX 2200 MULTI-ANALYTE DETECTION SYSTEMBio-Rad Laboratories May 8, 200979 days

Recalls

Recall records for product code MXJ per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MXJ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20171
20181
20191
20200
20212
20220
2023140
20243
20251
2026 (so far)2

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions2
  • Other or not stated0

Most reported device problems, last 12 months

  1. False Negative Result1
  2. False Positive Result1

In plain English: what the newest reports describe Written by AI

  • In eleven reports, people had positive herpes antibody blood tests on the IgG screening test, but a later Western blot, a more detailed confirmatory test, came back negative. The reports do not say which result was correct.

    11 reports: MW5118990, MW5118992, MW5118994, MW5118996, MW5118935, MW5118937, MW5118939, MW5118941, MW5116935, MW5116938, MW5116948

  • Two reports say the device's processing module gave nonreactive results, meaning no herpes antibodies were detected, for samples that other tests found positive. One report says this had been happening for an unknown length of time.

    2 reports: 3008344661-2026-00053, 3008344661-2024-00064

  • One report says a blood test for herpes antibodies gave an equivocal, or unclear, result for HSV-1. A later Western blot was negative, and the person described the unclear result as very distressing.

    Report: MW5153286

  • One report says a herpes test run as part of a panel, a group of tests done together, gave a false positive. A separate retest was negative, and the person described mental distress. The laboratory said panel testing carries a higher risk of false positives.

    Report: MW5168292

  • One report says two herpes IgG antibody tests were positive, though the person had no herpes symptoms. A confirmatory test later suggested the results were false positives. The person said partners stopped contact and that the retest cost them money out of pocket.

    Report: MW5154370

Written by AI from the narratives of the 16 newest reports that have one, received Apr 24, 2023 to Mar 13, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
43in the FDA’s Global Unique Device Identification Database
Establishment listings
21registered establishments that list this product code

Watch MXJ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MXJ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MXJ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.