Product codes

FDA product code

MVA: Orthosis, Cranial (FDA product code)

Follow MVA: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 882.5970
Review panel
Neurology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
430 in the last 12 months
Median review time
163 daysthe latest 25 decisions
Recall records
00 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code MVA per year, by decision date, 43 since 1998. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20181
20190
20200
20212
20223
20232
20241
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K241957 Talee, Talee PostOpInvent Medical USA, LLC Aug 30, 202458 days
K230444 Talee, Talee PostOpInvent Medical USA, LLC Jun 22, 2023121 days
K223238 STARband 3DOrthomerica Products, Inc. Apr 20, 2023182 days
K220681 Talee, Talee PostOPInvent Medical USA, LLC Sep 22, 2022198 days
K203134 Hanger Cranial Band 3DSymbion Logistics, LLC Jul 1, 2022620 days
K213587 MyCRO BandOtto Bock Healthcare LP Jun 9, 2022209 days
K193383 SnugKapHeadstart, Ltd. Jun 7, 2021550 days
K201426 MyCRO BandOtto Bock Healthcare LP Mar 26, 2021301 days
K180568 KidCapEastern Cranial Affiliates, LLC Oct 16, 2018225 days
K141842 STARBAND, STARLIGHTOrthomerica Products, Inc. Oct 6, 201490 days

Recalls

Recall records for product code MVA per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MVA. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20173
20180
20190
20200
20210
20221
20230
20240
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions0
  • Other or not stated1

Most reported device problems, last 12 months

  1. Break1
  2. Crack1
  3. Positioning Failure1
  4. Pressure Problem1

In plain English: what the newest reports describe Written by AI

  • Two reports describe an infant death or an infection after an implant, but the narratives do not give enough detail to link either to the orthosis. Two other reports describe a granuloma and a seroma after a brain surgery, and one describes a trepan (a surgical drill) that does not stop automatically. These reports are brief and unclear about the device involved.

    6 reports: 3003603920-2010-00001, 3009383407-2022-00001, 9610612-2017-00491, 9610612-2017-00494, 9610612-2017-00267, MW5008886

  • Several reports describe skin wounds on the head, such as pressure sores, abrasions, bruising, redness and scarring, caused by a helmet that fit poorly, or by adhesive or padding that came loose and rolled onto the skin. In one report the wounds were ongoing: each attempt to resume wearing the helmet caused new abrasions, so use had to be stopped for about three weeks at a time.

    4 reports: MW5043010, MW5017321, MW5062898, MW4002727

  • Several reports say a helmet fitted poorly or was made with improper specifications, which led to a worsening head shape or a new deformity. In one report, the child's head grew upward rather than outward and the helmet was adjusted repeatedly without fixing the fit.

    3 reports: MW1038148, MW4002727, MW1038142

  • Reports describe concerns with the 3D scanning step used to make the helmet. A baby moving its head during scanning was said to lead to an incorrect fit. One parent also worried that the scanner's laser could affect the eyes, but the report does not confirm any eye injury.

    2 reports: MW1038142, MW1038148

  • A cranial orthosis (a custom helmet worn to reshape a baby's head) cracked while being worn, and the opening near its side clip was reported to the provider several times before a crack was found. The provider glued the area, but it reopened, and the orthosis could no longer be seated properly, interrupting treatment.

    Report: MW6004566

Written by AI from the narratives of the 14 newest reports that have one, received Mar 30, 2000 to Oct 26, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
158in the FDA’s Global Unique Device Identification Database
Establishment listings
40registered establishments that list this product code

Product codes classified under the same regulation.

Watch MVA in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MVA every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MVA. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.