Product codes

FDA product code

MPD: Auxiliary Power Supply (Ac Or Dc) For Low-Energy Dc-Defibrillator (FDA product code)

Follow MPD: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.5300
Review panel
Cardiovascular
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
Yes
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
30 in the last 12 months
Median review time
88 daysthe latest 3 decisions
Recall records
00 in the last 12 months
Adverse event reports
9last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code MPD per year, by decision date, 3 since 2007. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20241
20251
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K253099 LIFEPAK 15 AC Power Adapter (41577-000333)Physio-Control, Inc. Oct 14, 202520 days
K240162 LIFEPAK® 35 AC Power Adapter (41335-000001)Stryker Physio-Control Apr 19, 202488 days
K062331 HIGHPAK-12Ad Elektronik GmbH Jul 10, 2007334 days

Recalls

Recall records for product code MPD per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MPD. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20210
20220
20230
20240
202511
2026 (so far)9

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions8
  • Other or not stated0

Most reported device problems, last 12 months

  1. Intermittent Loss of Power4
  2. Defective Component3
  3. Device Stenosis1

In plain English: what the newest reports describe Written by AI

  • Clinicians and biomedical staff found that the AC power adapter, which powers the defibrillator, sometimes fails during routine rounds. Reports describe these failures without stating a cause.

    3 reports: MW5176994, MW5174179, MW6002403

  • The manufacturer's reports say no patient was harmed by these adapter failures. One report says no patient was involved in the incidents.

    2 reports: MW5176994, MW5174179

  • One report says defibrillator power supplies that were replaced during a previous recall are still failing, including devices outside that recall. Some defibrillators needed their power supply replaced more than once, and problems come and go.

    Report: MW6002403

  • One report says a heart monitor showed a heart rate of 52 when the patient's actual rate was about 115. Staff found the display was correct after the ECG cables were disconnected and reconnected.

    Report: MW5184398

Written by AI from the narratives of the 5 newest reports that have one, received Aug 7, 2025 to Sep 16, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
9in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Product codes classified under the same regulation.

Watch MPD in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MPD every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MPD. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.