Product codes

FDA product code

MOF: Guide, Wire, Catheter, Neurovasculature (FDA product code)

Follow MOF: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.1330
Review panel
Neurology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
4511 in the last 12 months
Median review time
192 daysthe latest 25 decisions
Recall records
20 in the last 12 months
Adverse event reports
173last 12 months, 1 death

510(k) and De Novo decisions

Decisions for product code MOF per year, by decision date, 45 since 2011. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20182
20194
20204
20210
20221
20234
20242
20255
2026 (so far)11

Latest decisions

NumberDevice and applicantDecision and review time
K254181 Aristotle 65 MacrowireScientia Vascular Sep 16, 2026267 days
K260751 35 Helix GuidewirePiraeus Medical, Inc. Aug 27, 2026174 days
K262424 Willow 12 GuidewireArbor Endovascular, LLC Aug 14, 202629 days
K260223 Aristotle Mini GuidewireScientia Vascular, Inc. Aug 6, 2026192 days
K254006 Drivewire 35 GuidewireRapid Medical Ltd. Jul 17, 2026214 days
K253579 Aristotle 14 Guidewire; Aristotle 18 Guidewire; Aristotle 24 Guidewire; Zoom Wire 14 GuidewireScientia Vascular, Inc. Apr 29, 2026163 days
K252317 Zenith Micro GuidewireSuzhou Zenith Vascular SciTech Limited Apr 16, 2026265 days
K260537 Willow 24 GuidewireArbor Endovascular, LLC Mar 19, 202630 days
K252122 DCwire Micro-guidewireShanghai Achieva Medical Suzhou Co., Ltd. Mar 16, 2026252 days
K260130 Willow 18 GuidewireArbor Endovascular, LLC Feb 13, 202628 days

Recalls

Recall records for product code MOF per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1940-2024Class II Stryker NeurovascularStryker Neurovascular has observed an increased frequency of PTFE coating damage occurring on the Synchro Guidewires that may be caused by the practice of back… Apr 18, 2024
Z-3103-2017Class II Microvention, Inc.There is a potential for the hydrophilic coating on the guidewire to delaminate from the guidewire. Aug 7, 2017

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MOF. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201715
201811
201912
202018
202139
202292
202391
202495
2025137
2026 (so far)153

Last 12 months by event type

  • Deaths1
  • Injuries31
  • Malfunctions139
  • Other or not stated2

Most reported device problems, last 12 months

  1. Fracture75
  2. Break51
  3. Failure to Advance22
  4. Peeled/Delaminated13
  5. Adverse Event Without Identified Device or Use Problem8
  6. Material Deformation2

In plain English: what the newest reports describe Written by AI

  • Guidewires (thin wires threaded through blood vessels to guide devices) fractured or broke at the tip or distal section during use, in many reports, and in some cases fragments stayed in the patient. The reports describe the tip breaking after the wire was pulled back or resisted during advancement.

    15 reports: 3012931345-2026-00146, 3012931345-2026-00142, 3012931345-2026-00140, 3012931345-2026-00134, 3012931345-2026-00136, 3012931345-2026-00133, 3012931345-2026-00115, 3012931345-2026-00113, 3012931345-2026-00111, 3012931345-2026-00108, 3009546466-2026-00059, 3009546466-2026-00058, 3009546466-2026-00055, MW6003438, MW6002136

  • Several reports describe a wire that would not respond well to pushing or turning (torque) once inside the body, so the physician could not steer it to the target. The wire was then removed and replaced with a new one.

    5 reports: 3012931345-2026-00142, 3012931345-2026-00140, 3012931345-2026-00136, 3012931345-2026-00111, 3012931345-2026-00108

  • In several reports the outer coating of the wire was damaged or peeled off while it was pulled through a sheath or catheter. One report notes that shavings were found stuck to the wire. In these reports no harm to the patient was described.

    3 reports: 3012931345-2026-00120, 3003775027-2026-00136, 3003775027-2026-00142

  • In a few reports a broken wire piece was left in the blood vessel because it could not be retrieved. The manufacturer's findings are not stated in these reports.

    2 reports: 3012931345-2026-00146, 3009546466-2026-00059

  • One report describes a guidewire that pushed through the wall of an aneurysm, a small weakened bulge in an artery, causing a small brain bleed. The patient was discharged 8 days later without neurological problems, and the report says the wire was the cause.

    Report: 3012931345-2026-00145

Written by AI from the narratives of the 20 newest reports that have one, received Jul 10, 2026 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
165in the FDA’s Global Unique Device Identification Database
Establishment listings
98registered establishments that list this product code

Product codes classified under the same regulation.

Watch MOF in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MOF every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MOF. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy