MLM: Enzyme Immunoassay, Tracrolimus (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 862.1678
- Review panel
- Clinical Toxicology
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 90 in the last 12 months
- Median review time
- 147 daysthe latest 9 decisions
- Recall records
- 121 in the last 12 months
- Adverse event reports
- 17last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code MLM per year, by decision date, 9 since 2005. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 1 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 1 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K203833 | Tacrolimus Assay KitShanghai Genext Medical Technology Co., Ltd. | Jan 27, 2023758 days |
| K173857 | Elecsys TacrolimusRoche Diagnostics | Nov 6, 2018321 days |
| K150168 | Dimension Tacrolimus Flex® Reagent Cartridge (TAC), Dimension Tacrolimus Calibrator (TAC CAL)Siemens Healthcare Diagnostics | Nov 4, 2015282 days |
| K123343 | THERMO SCIENTIFIC QMS TACROLIMUS ASSAY AND CALIBRATORSMicrogenics Corp. | Jul 11, 2013253 days |
| K070820 | ARCHITECT TACROLIMUS: MODEL 1L77Fujirebio Diagnostics,Inc. | Aug 1, 2007128 days |
| K063868 | MASSTRAK IMMUNOSUPPRESSANTS KITWaters Corporation | May 25, 2007147 days |
| K060502 | DIMENSION TACR FLEX REAGENT CARTRIDGE, MODEL DF107Dade Behring, Inc. | May 18, 200683 days |
| K060385 | EMIT 2000 TACROLIMUS ASSAY AND SAMPLE PRETREATMENT REAGENTDade Behring, Inc. | Apr 6, 200651 days |
| K050206 | CEDIA TACROLIMUS ASSAYMicrogenics Corp. | Mar 15, 200546 days |
Recalls
Recall records for product code MLM per year, by the date the recall began. Each recalled product is one record; these 12 records belong to 12 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 1 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 1 |
| 2023 | 1 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-2398-2026Class II | Siemens Healthcare Diagnostics, Inc.A potential positive bias in quality control (QC) and patient sample results in three lots of the Dimension Tacrolimus (TAC) Flex reagent cartridge. | May 7, 2026 |
| Z-1258-2023Class II | Siemens Healthcare Diagnostics, Inc.Siemens Healthineers has received customer complaints and confirmed imprecision for Quality Control (QC) and patient samples with Dimension Tacrolimus (TAC) lo… | Jan 30, 2023 |
| Z-1284-2022Class II | Microgenics CorporationDue to QMS Tacrolimus Calibrator recovering between 82 to 94% of their target values, resulting in over-quantitation in tacrolimus patient result values when u… | Jan 20, 2022 |
| Z-1661-2018Class II | Siemens Healthcare Diagnostics, Inc.Various assays used to measure different chemical levels in blood, urine, or cerebrospinal fluid may interfere with the drugs sulfasalazine and/or sulfapyridin… | Jun 29, 2017 |
| Z-1464-2015Class II | Diasorin Inc.Instability in the PRO-Trac II Tacrolimus ELISA kit which may cause falsely elevated patient results. | Mar 16, 2015 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code MLM. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 2 |
| 2018 | 26 |
| 2019 | 7 |
| 2020 | 4 |
| 2021 | 1 |
| 2022 | 23 |
| 2023 | 54 |
| 2024 | 62 |
| 2025 | 8 |
| 2026 (so far) | 15 |
Last 12 months by event type
- Deaths0
- Injuries0
- Malfunctions17
- Other or not stated0
Most reported device problems, last 12 months
- High Test Results12
- Low Test Results8
- Non Reproducible Results3
- Incorrect Measurement2
- Incorrect, Inadequate or Imprecise Result or Readings1
In plain English: what the newest reports describe Written by AI
Tacrolimus, a drug level measured in blood, came back higher than expected on an integrated chemistry analyzer in these reports. Repeat tests on the same analyzer gave lower values, which the reporters judged correct, and the high first results were often not reported to physicians.
7 reports: 2517506-2026-00096, 2517506-2026-00089, 2517506-2026-00045, 2517506-2026-00046, 2517506-2026-00056, 2517506-2026-00079, 2517506-2026-00048
Some reports describe Tacrolimus results that were lower than expected on an analyzer. Repeat tests, on the same analyzer or on another analyzer or at another facility, gave higher values, which were judged correct.
4 reports: 2517506-2026-00099, 2517506-2025-00050, 2432235-2026-00222, 2432235-2026-00062
Three reports say an analyzer's Tacrolimus results did not match results from mass spectrometry, a more specialized lab method, or from repeat testing. The differences went in both directions, and physicians questioned results that did not fit the patient's history.
3 reports: 1823260-2026-00691, 1823260-2025-05052, 1823260-2025-00952
Two reports describe initial Tacrolimus results above the measuring limit, over 40 or over 60 micrograms per liter. Repeat testing gave much lower values, and in one case the drug was stopped for five days.
2 reports: 1823260-2025-05233, 3008344661-2025-00086
One report describes a Tacrolimus sample run in a standard rack giving 10.1 ng/mL, while the repeat run in the customer's usual dedicated sample rack gave 6.66 ng/mL, which the manufacturer deemed correct.
Report: 1823260-2026-04475
Written by AI from the narratives of the 19 newest reports that have one, received Mar 26, 2025 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 16in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 14registered establishments that list this product code
Watch MLM in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get MLM every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MLM. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:MLMRetrieved Nov 28, 2026, 11:07 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:MLMRetrieved Nov 29, 2026, 7:56 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:MLM · count decision_dateRetrieved Nov 28, 2026, 11:07 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:MLMRetrieved Nov 29, 2026, 7:56 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:MLM · count event_date_initiatedRetrieved Nov 28, 2026, 11:07 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:MLM · count res_event_numberRetrieved Nov 28, 2026, 11:07 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-2398-2026" "Z-1258-2023" "Z-1284-2022" "Z-1661-2018" "Z-1464-2015")Retrieved Nov 29, 2026, 7:56 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:MLM AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 7:56 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:MLM AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 7:56 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:MLM AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 7:56 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:MLMRetrieved Nov 28, 2026, 11:07 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:MLMRetrieved Nov 28, 2026, 11:07 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:862.1678Retrieved Nov 28, 2026, 11:07 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.