MKJ: Automated External Defibrillators (Non-Wearable) (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class III
- Regulation
- 21 CFR 870.5310
- Review panel
- Cardiovascular
- Premarket route
- PMA
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- PMA decisions
- 29417 original PMAs, the rest supplements
- Median review time
- 28 daysthe latest 25 decisions
- Recall records
- 3364 in the last 12 months
- Adverse event reports
- 11,278last 12 months, 123 deaths
PMA decisions
Original PMAs and supplements for product code MKJ per year, by decision date, 294 since 2017. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 4 |
| 2018 | 20 |
| 2019 | 25 |
| 2020 | 52 |
| 2021 | 41 |
| 2022 | 19 |
| 2023 | 24 |
| 2024 | 27 |
| 2025 | 48 |
| 2026 (so far) | 34 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| P200005 S001 | TZ MEDICAL MULTI FUNCTION DEFIBRILLATION ELECTRODES; Adult nonsterile, leads out, radiotranslucent (P-111-T1); Adult nonTz Medical, Inc. | Nov 13, 202688 days |
| P160026 S058 | LIFEPAK Automated External Defibrillators (AEDs)Physio-Control, Inc. | Nov 12, 2026561 days |
| P160026 S076 | LIFEPAK® 35 monitor/defibrillatorPhysio-Control, Inc. | Oct 29, 202630 days |
| P160015 S029 | AED 3 Defibrillator with Uni-PadzZOLL Medical Corporation | Oct 16, 202628 days |
| P160022 S056 | ZOLL R Series Monitor/DefibrillatorZOLL Medical Corporation | Oct 16, 202616 days |
| P160022 S054 | X Series®, R Series®, AED Pro®, AED 3™ BLS Professional Defibrillators, Pro-Padz Radiotransparent Electrode, SurePower™ZOLL Medical Corporation | Oct 2, 202628 days |
| P160026 S074 | LIFEPAK 1000 DEFIBRILLATOR, LIFEPAK 20 DEFIBRILLATOR/ MONITOR, LIFEPAK 20E DEFIBRILLATOR/ MONITOR, LIFEPAK 15 MONITOR/DEPhysio-Control, Inc. | Sep 24, 202622 days |
| P160026 S073 | LIFEPAK® 15 monitor/defibrillatorPhysio-Control, Inc. | Sep 10, 202628 days |
| P160026 S069 | LIFEPAK® 35 monitor/defibrillatorPhysio-Control, Inc. | Sep 2, 202690 days |
| P160026 S072 | Physio-Control LIFEPAK®35 monitor/defibrillatorPhysio-Control, Inc. | Aug 28, 202617 days |
Recalls
Recall records for product code MKJ per year, by the date the recall began. Each recalled product is one record; these 336 records belong to 216 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 12 |
| 2018 | 12 |
| 2019 | 12 |
| 2020 | 16 |
| 2021 | 6 |
| 2022 | 3 |
| 2023 | 14 |
| 2024 | 8 |
| 2025 | 20 |
| 2026 (so far) | 4 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-3120-2026Class II | HeartSine Technologies LtdDue to a damaged (over stretched) membrane tail that causes an intermittent fault. | Jul 27, 2026 |
| Z-3270-2026Class III | HeartSine Technologies LtdProducts were distributed without the required Maintenance Supplement, which describes an extra check every 3 months in addition to the monthly check. | Jul 27, 2026 |
| Z-2065-2026Class II | Physio-Control, Inc.Some defibrillators serviced between July 2023 through November 2025 were serviced without objective evidence that a Performance Inspection Procedure (PIP) was… | Apr 13, 2026 |
| Z-1544-2026Class II | Physio-Control, Inc.Due to pediatric defibrillator electrode delamination | Jan 21, 2026 |
| Z-0288-2026Class II | HeartSine Technologies LtdDue to customer complaints, defibrillator pads may contain damage pins that disrupt the mechanical fit and electrical contact. | Sep 18, 2025 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code MKJ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 16,684 |
| 2018 | 16,591 |
| 2019 | 16,861 |
| 2020 | 16,197 |
| 2021 | 16,300 |
| 2022 | 14,867 |
| 2023 | 13,766 |
| 2024 | 15,113 |
| 2025 | 13,472 |
| 2026 (so far) | 9,903 |
Last 12 months by event type
- Deaths123
- Injuries145
- Malfunctions10,996
- Other or not stated14
Most reported device problems, last 12 months
- Failure to Power Up2,477
- Failure of Device to Self-Test1,084
- Unable to Obtain Readings1,066
- Premature Discharge of Battery785
- Defibrillation/Stimulation Problem775
- Material Deformation657
In plain English: what the newest reports describe Written by AI
Several reports describe a device that would not power on, sometimes only intermittently, found during routine checks or biomed testing. One report notes that a spare battery pack let the device power on, and no patient use was reported in these cases.
6 reports: 1220908-2026-04184, 1220908-2026-04287, 1220908-2026-04281, 3003521780-2026-01883, 3004123209-2026-00519, 0003015876-2026-02188
Several reports describe a service code or error message appearing on the device, including a flashing red status light, a blank screen, and a 'defib fault 76' message. The manufacturer's reports do not say what caused these codes.
4 reports: 3003521780-2026-01697, 3003521780-2026-01880, 1220908-2026-04313, 1220908-2026-04417
One report describes the device's screen turning completely white and becoming unreadable during a routine check, and another reports the device's buttons were inoperable while the display still showed data during patient use. In a further report, the manufacturer found the magnet missing from the lid, which means the device may not turn on automatically when the lid is opened.
3 reports: 1220908-2026-04328, 0003015876-2026-02189, 0003015876-2026-02190
Several reports describe the device's defibrillation function failing self-test or being disabled. The defibrillator is the part that delivers the shock to restart the heart, so a failure here means therapy may not be available if needed.
2 reports: 1220908-2026-04171, 0003015876-2026-02187
Two reports describe the device failing its self-test for pacing, or being unable to pace. Pacing is the function that sends electrical pulses to keep the heart beating, and one report says the device was unable to pace while treating a patient, with no adverse effect reported.
2 reports: 1220908-2026-04288, 1220908-2026-04416
Written by AI from the narratives of the 19 newest reports that have one, received Oct 29, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 4,017in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 202registered establishments that list this product code
Other codes under 21 CFR 870.5310
Product codes classified under the same regulation.
Watch MKJ in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get MKJ every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MKJ. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:MKJRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:MKJRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:MKJ · count decision_dateRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:MKJ · count pma_numberRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:MKJRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:MKJ · count event_date_initiatedRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:MKJ · count res_event_numberRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-3120-2026" "Z-3270-2026" "Z-2065-2026" "Z-1544-2026" "Z-0288-2026")Retrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:MKJ AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:MKJ AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:MKJ AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:MKJRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:MKJRetrieved Nov 29, 2026, 5:38 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:870.5310Retrieved Nov 28, 2026, 11:52 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.