FDA product code

MKJ: Automated External Defibrillators (Non-Wearable) (FDA product code)

Follow MKJ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class III
Regulation
21 CFR 870.5310
Review panel
Cardiovascular
Premarket route
PMA
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
PMA decisions
29417 original PMAs, the rest supplements
Median review time
28 daysthe latest 25 decisions
Recall records
3364 in the last 12 months
Adverse event reports
11,278last 12 months, 123 deaths

PMA decisions

Original PMAs and supplements for product code MKJ per year, by decision date, 294 since 2017. Review time is the days from receipt to decision.

All of them in the FDA’s PMA database

PMA decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20174
201820
201925
202052
202141
202219
202324
202427
202548
2026 (so far)34

Latest decisions

NumberDevice and applicantDecision and review time
P200005 S001 TZ MEDICAL MULTI FUNCTION DEFIBRILLATION ELECTRODES; Adult nonsterile, leads out, radiotranslucent (P-111-T1); Adult nonTz Medical, Inc. Nov 13, 202688 days
P160026 S058 LIFEPAK Automated External Defibrillators (AEDs)Physio-Control, Inc. Nov 12, 2026561 days
P160026 S076 LIFEPAK® 35 monitor/defibrillatorPhysio-Control, Inc. Oct 29, 202630 days
P160015 S029 AED 3 Defibrillator with Uni-PadzZOLL Medical Corporation Oct 16, 202628 days
P160022 S056 ZOLL R Series Monitor/DefibrillatorZOLL Medical Corporation Oct 16, 202616 days
P160022 S054 X Series®, R Series®, AED Pro®, AED 3™ BLS Professional Defibrillators, Pro-Padz Radiotransparent Electrode, SurePower™ZOLL Medical Corporation Oct 2, 202628 days
P160026 S074 LIFEPAK 1000 DEFIBRILLATOR, LIFEPAK 20 DEFIBRILLATOR/ MONITOR, LIFEPAK 20E DEFIBRILLATOR/ MONITOR, LIFEPAK 15 MONITOR/DEPhysio-Control, Inc. Sep 24, 202622 days
P160026 S073 LIFEPAK® 15 monitor/defibrillatorPhysio-Control, Inc. Sep 10, 202628 days
P160026 S069 LIFEPAK® 35 monitor/defibrillatorPhysio-Control, Inc. Sep 2, 202690 days
P160026 S072 Physio-Control LIFEPAK®35 monitor/defibrillatorPhysio-Control, Inc. Aug 28, 202617 days

Recalls

Recall records for product code MKJ per year, by the date the recall began. Each recalled product is one record; these 336 records belong to 216 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
201712
201812
201912
202016
20216
20223
202314
20248
202520
2026 (so far)4

Latest recalls

Recall and classFirm and reasonBegan
Z-3120-2026Class II HeartSine Technologies LtdDue to a damaged (over stretched) membrane tail that causes an intermittent fault. Jul 27, 2026
Z-3270-2026Class III HeartSine Technologies LtdProducts were distributed without the required Maintenance Supplement, which describes an extra check every 3 months in addition to the monthly check. Jul 27, 2026
Z-2065-2026Class II Physio-Control, Inc.Some defibrillators serviced between July 2023 through November 2025 were serviced without objective evidence that a Performance Inspection Procedure (PIP) was… Apr 13, 2026
Z-1544-2026Class II Physio-Control, Inc.Due to pediatric defibrillator electrode delamination Jan 21, 2026
Z-0288-2026Class II HeartSine Technologies LtdDue to customer complaints, defibrillator pads may contain damage pins that disrupt the mechanical fit and electrical contact. Sep 18, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MKJ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201716,684
201816,591
201916,861
202016,197
202116,300
202214,867
202313,766
202415,113
202513,472
2026 (so far)9,903

Last 12 months by event type

  • Deaths123
  • Injuries145
  • Malfunctions10,996
  • Other or not stated14

Most reported device problems, last 12 months

  1. Failure to Power Up2,477
  2. Failure of Device to Self-Test1,084
  3. Unable to Obtain Readings1,066
  4. Premature Discharge of Battery785
  5. Defibrillation/Stimulation Problem775
  6. Material Deformation657

In plain English: what the newest reports describe Written by AI

  • Several reports describe a device that would not power on, sometimes only intermittently, found during routine checks or biomed testing. One report notes that a spare battery pack let the device power on, and no patient use was reported in these cases.

    6 reports: 1220908-2026-04184, 1220908-2026-04287, 1220908-2026-04281, 3003521780-2026-01883, 3004123209-2026-00519, 0003015876-2026-02188

  • Several reports describe a service code or error message appearing on the device, including a flashing red status light, a blank screen, and a 'defib fault 76' message. The manufacturer's reports do not say what caused these codes.

    4 reports: 3003521780-2026-01697, 3003521780-2026-01880, 1220908-2026-04313, 1220908-2026-04417

  • One report describes the device's screen turning completely white and becoming unreadable during a routine check, and another reports the device's buttons were inoperable while the display still showed data during patient use. In a further report, the manufacturer found the magnet missing from the lid, which means the device may not turn on automatically when the lid is opened.

    3 reports: 1220908-2026-04328, 0003015876-2026-02189, 0003015876-2026-02190

  • Several reports describe the device's defibrillation function failing self-test or being disabled. The defibrillator is the part that delivers the shock to restart the heart, so a failure here means therapy may not be available if needed.

    2 reports: 1220908-2026-04171, 0003015876-2026-02187

  • Two reports describe the device failing its self-test for pacing, or being unable to pace. Pacing is the function that sends electrical pulses to keep the heart beating, and one report says the device was unable to pace while treating a patient, with no adverse effect reported.

    2 reports: 1220908-2026-04288, 1220908-2026-04416

Written by AI from the narratives of the 19 newest reports that have one, received Oct 29, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
4,017in the FDA’s Global Unique Device Identification Database
Establishment listings
202registered establishments that list this product code

Product codes classified under the same regulation.

Watch MKJ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MKJ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MKJ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.