Product codes

FDA product code

MGZ: Valvulotome (FDA product code)

Follow MGZ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.4885
Review panel
Cardiovascular
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
271 in the last 12 months
Median review time
169 daysthe latest 25 decisions
Recall records
61 in the last 12 months

510(k) and De Novo decisions

Decisions for product code MGZ per year, by decision date, 27 since 1991. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20191
20200
20210
20221
20230
20240
20251
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K260188 LimFlow VectorLimFlow, Inc. Mar 18, 202655 days
K250105 Boomerang Valvulotome (BMGVT080); Boomerang Push Valvulotome (BMGPVT125)Aveera Medical, Inc. Jul 3, 2025169 days
K221902 LimFlow VectorLimFlow, Inc. Dec 21, 2022174 days
K190267 EZE SIT ValvulotomeLemaitre Vascular Oct 30, 2019264 days
K142660 Antegrade LeMills ValvulotomeLeMaitre Vascular, Inc. Oct 17, 201429 days
K140042 1.5MM HYDRO EXPANDABLE LEMAITRE VALVULOTOMELeMaitre Vascular, Inc. Apr 10, 201492 days
K132047 LEMILLS VALVULOTOMELeMaitre Vascular, Inc. Nov 5, 2013126 days
K132190 EXPANDABLE LEMAITRE VALVULOTOME, OVER-THE-WIRE LEMAITRE VALVULOTOMELeMaitre Vascular, Inc. Aug 5, 201321 days
K111884 OVER-THE-WIRE EXPANDABLE LEMAITRE VALVULOTOMELeMaitre Vascular, Inc. Jul 29, 201128 days
K080178 VALVULOTOME BY KOVENKoven Technology, Inc. Jul 28, 2008186 days

Recalls

Recall records for product code MGZ per year, by the date the recall began. Each recalled product is one record; these 6 records belong to 4 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20231
20240
20251
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1218-2026Class II LimFlow, Inc.Incorrect expiration date Dec 5, 2025
Z-2468-2023Class II LeMaitre Vascular, Inc.Burrs (molding flash) on the cutter may tear the harvested vien Jul 13, 2023
Z-2543-2016Class II LeMaitre Vascular, Inc.Wire which deploys the loop may be come detached at the handle causing the device to be inoperable Aug 3, 2016
Z-2544-2016Class II LeMaitre Vascular, Inc.Wire which deploys the loop may be come detached at the handle causing the device to be inoperable Aug 3, 2016
Z-2545-2016Class II LeMaitre Vascular, Inc.Wire which deploys the loop may be come detached at the handle causing the device to be inoperable Aug 3, 2016

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MGZ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

This section didn’t load from openFDA. It’s retried within the hour.

Last 12 months by event type

This section didn’t load from openFDA. It’s retried within the hour.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
48in the FDA’s Global Unique Device Identification Database
Establishment listings
27registered establishments that list this product code

Product codes classified under the same regulation.

Watch MGZ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MGZ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MGZ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.