Product codes

FDA product code

MAL: Graft, Vascular, Synthetic/Biologic Composite (FDA product code)

Follow MAL: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.3450
Review panel
Cardiovascular
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
60 in the last 12 months
Median review time
56 daysthe latest 6 decisions
Recall records
490 in the last 12 months
Adverse event reports
14last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code MAL per year, by decision date, 6 since 1996. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K122612 HEMASHIELD WOVEN DOUBLE VELOUR VASCULAR GRAFT MODEL M00202175XXXXX; M00202166XXXXXMaquet Cardiovascular, LLC Sep 10, 201214 days
K103080 ALBOGRAFT VASCULAR PROSTHESISLeMaitre Vascular, Inc. Jan 19, 201192 days
K093231 ALBOGRAFT VASCULAR PROSTHESISLeMaitre Vascular, Inc. Jan 14, 201092 days
K052302 HEMASHIELD PLATINUM WOVEN DOUBLE VELOUR TAAA GRAFT CONFIGURATIONBoston Scientific Corp Sep 12, 200519 days
K021213 MODIFICATION TO HEMASHIELD PLATINUM WOVEN/MICROVEL DOUBLE VELOUR VASCULAR GRAFTSBoston Scientific Corp Apr 19, 20022 days
K954848 HEMASHIELD MICROVEL VELOUR KNITTED VASCULAR GRAFTMeadox Medicals, Div. Boston Scientific Corp. Feb 1, 1996101 days

Recalls

Recall records for product code MAL per year, by the date the recall began. Each recalled product is one record; these 49 records belong to 7 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20191
202024
20211
20221
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0729-2022Class II Maquet Cardiovascular, LLCOuter labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Bifurcated Vascular Graft, D: 16 x 8 mm; L: 40 cm) does not correspond to the (inner) sterile p… Jan 14, 2022
Z-0403-2022Class II Maquet Cardiovascular, LLCThere is a probable mislabeling of product. A Hemashield Platinum Woven Double Velour Bifurcated Vasuclar Graft, SN 1259735369, 24 mm x 12 mm, REF Number M0020… Dec 1, 2021
Z-1859-2020Class II Maquet Cardiovascular, LLCPotential small holes at the seam lines of Hemashield branches causing intra-operative bleeding at the seam lines of the branches of Hemashield grafts Apr 7, 2020
Z-1860-2020Class II Maquet Cardiovascular, LLCPotential small holes at the seam lines of Hemashield branches causing intra-operative bleeding at the seam lines of the branches of Hemashield grafts Apr 7, 2020
Z-1861-2020Class II Maquet Cardiovascular, LLCPotential small holes at the seam lines of Hemashield branches causing intra-operative bleeding at the seam lines of the branches of Hemashield grafts Apr 7, 2020

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MAL. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201728
201815
201928
202024
202134
202221
202316
202410
202528
2026 (so far)13

Last 12 months by event type

  • Deaths0
  • Injuries6
  • Malfunctions8
  • Other or not stated0

Most reported device problems, last 12 months

  1. Product Quality Problem5
  2. Insufficient Device Problem Information3
  3. Material Puncture/Hole2
  4. Adverse Event Without Identified Device or Use Problem1
  5. Improper or Incorrect Procedure or Method1
  6. Off-Label Use1

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
373in the FDA’s Global Unique Device Identification Database
Establishment listings
16registered establishments that list this product code

Watch MAL in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MAL every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MAL. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.