Product codes

FDA product code

LRT: Indicator, Sterilization (FDA product code)

Follow LRT: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 880.2800
Review panel
General Hospital
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
50 in the last 12 months
Median review time
270 daysthe latest 5 decisions
Recall records
10 in the last 12 months
Adverse event reports
2last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code LRT per year, by decision date, 5 since 1987. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K002937 TST CONTROL INTEGRATOR FOR STEAM STERILIZERSAlbert Browne , Ltd. Nov 5, 2001410 days
K965154 TST CONTROL INTEGRATOR FOR STEAM AUTOCLAVEAlbert Browne , Ltd. Sep 19, 1997270 days
K951113 CROSS-CHECKSSteritec Products Mfg Co, Inc. Aug 19, 1996528 days
K951703 TAMPER EVIDENT ARROWS WITH AND WITHOUT STERILIZATION INDICATORSProducts For Medicine Jun 28, 199577 days
K871672 STERILIZATION INDICATOR FOR FLASH STERILIZATIONPropper Mfg. Co., Inc. Jun 1, 198734 days

Recalls

Recall records for product code LRT per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2325-2012Class III Steris CorporationOn 7/20/2012 the firm became aware that a lot of tubing was distributed by the supplier after it was rejected by Steris due to failing process indicators. Aug 2, 2012

Adverse event reports (MAUDE)

Medical device reports received per year that name product code LRT. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20210
20220
20234
20240
20254
2026 (so far)0

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions2
  • Other or not stated0

Most reported device problems, last 12 months

  1. Material Puncture/Hole2

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
21in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Watch LRT in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get LRT every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LRT. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.