Product codes

FDA product code

LRC: Instrument, Ent Manual Surgical (FDA product code)

Follow LRC: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 874.4420
Review panel
Ear, Nose and Throat
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
650 in the last 12 months
Median review time
92 daysthe latest 25 decisions
Recall records
50 in the last 12 months
Adverse event reports
27last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code LRC per year, by decision date, 65 since 1987. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20181
20191
20204
20210
20221
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K230258 BB 8 Sinus Dilation KitExcelent, Inc. May 25, 2023114 days
K212774 VenSure LightGuideIntersect Ent. Feb 4, 2022156 days
K201398 SINUSPRIME Dilation SystemStryker Ent Oct 15, 2020140 days
K201115 Next Generation Balloon Dilation SystemAcclarent, Inc. Aug 27, 2020122 days
K201472 VenSure Balloon Device, VenSure Nav Balloon DeviceFiagon GmbH Aug 26, 202084 days
K181546 Dillard Nasal Balloon CatheterIntuit Medical Products, LLC Jan 3, 2020570 days
K190525 RELIEVA ULTIRRA Sinus Balloon CatheterAcclarent, Inc. May 3, 201960 days
K181838 Sinusway Dilation System3nt Medical , Ltd. Dec 20, 2018163 days
K172737 MESIRE - Balloon Sinus Dilatation SystemM/S. Meril Life Sciences Private Limited Dec 12, 201792 days
K171687 Relieva SpinPlus Nav Balloon Sinuplasty SystemAcclarent, Inc. Sep 5, 201790 days

Recalls

Recall records for product code LRC per year, by the date the recall began. Each recalled product is one record; these 5 records belong to 5 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20231
20242
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0837-2025Class II Karl Storz EndoscopyDue to failure of manual cleaning validation, biopsy and grasping forceps like sterility assurance. Dec 19, 2024
Z-1474-2024Class II Karl Storz EndoscopyInadequate reprocessing validation evidence Feb 27, 2024
Z-0574-2024Class II Karl Storz EndoscopyThe efficacy of the manual cleaning process cannot be assured for the affected injection needles intended for general surgery and visceral surgery, which if us… Oct 24, 2023
Z-1439-2013Class II Gyrus Acmi, Incorporatedlack of sterility assurance May 24, 2013
Recall Acclarent IncDevice sterility may be compromised as evidenced by a loss of package integrity. Jan 20, 2006

Adverse event reports (MAUDE)

Medical device reports received per year that name product code LRC. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201732
201842
201919
202020
202123
202225
202314
202451
202544
2026 (so far)21

Last 12 months by event type

  • Deaths0
  • Injuries13
  • Malfunctions14
  • Other or not stated0

Most reported device problems, last 12 months

  1. Break8
  2. Detachment of Device or Device Component7
  3. Degraded3
  4. Failure to Cut3
  5. Fracture3
  6. Adverse Event Without Identified Device or Use Problem2

In plain English: what the newest reports describe Written by AI

  • Four reports say cutting tools did not work properly, with punches not cutting in two of them. In one, a cut was unsatisfactory and other scissors were used to remove damaged tissue. No health impact is stated.

    4 reports: 9610617-2026-01517, 9610617-2026-01518, 9610617-2026-01167, 9610617-2026-00333

  • Three reports describe a cleaning brush for a laryngectomy valve (used by people whose voice box was removed). The brush head or bristle end broke off and fell into the airway. Two reports say a bronchoscopy, a camera procedure, was done to remove it.

    3 reports: 3002806269-2026-00028, 3007501574-2026-00009, 3007501574-2026-00006

  • Three reports describe surgical instruments that bent or broke, including a shaft that snapped at a welded joint. In one, hooks used in the ear bent and broke off during a procedure. No health impact is stated in these reports.

    3 reports: 9610617-2026-00012, 9610617-2026-00207, 9610617-2026-01321

  • Two identical reports describe a grasper (a tool with jaws) that broke while a foreign object was being removed from a patient's airway during bronchoscopy. The reporter said extra force was needed because the case was complex, and the case was stopped.

    2 reports: 9610617-2026-00556, 2020550-2026-00536

  • Two reports describe severe, daily facial and head pain after a balloon procedure. One report says CT or MRI scans after the procedure diagnosed a nerve injury, and that the pain has worsened and is unresolved.

    2 reports: 3009613036-2026-00001, MW5182829

Written by AI from the narratives of the 18 newest reports that have one, received Dec 15, 2025 to Sep 10, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
8,384in the FDA’s Global Unique Device Identification Database
Establishment listings
288registered establishments that list this product code

Watch LRC in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get LRC every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LRC. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.