Product codes

FDA product code

LNZ: Changer, Tube, Endotracheal (FDA product code)

Follow LNZ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.5730
Review panel
Anesthesiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
10 in the last 12 months
Median review time
29 daysthe latest 1 decisions
Recall records
30 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code LNZ per year, by decision date, 1 since 2010. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K102127 ENDOTRACHEAL TUBE CHANGERSInstrumentation Industries, Inc. Aug 27, 201029 days

Recalls

Recall records for product code LNZ per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20242
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1307-2024Class II Sarnova HC, LlcEndotracheal Tube Holder included in certain kits is not compatible with a nasal intubation procedure, leaving practitioners without the necessary means to sec… Feb 12, 2024
Z-1308-2024Class II Sarnova HC, LlcEndotracheal Tube Holder included in certain kits is not compatible with a nasal intubation procedure, leaving practitioners without the necessary means to sec… Feb 12, 2024
Z-0129-2007 Teleflex MedicalBiological indicator failed. Investigation eliminated all equipment and product related factors. Sep 27, 2006

Adverse event reports (MAUDE)

Medical device reports received per year that name product code LNZ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20181
20190
20201
20214
20224
20231
20240
20253
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Inadequate or Insufficient Training1

In plain English: what the newest reports describe Written by AI

  • Multiple reports describe the tube's cuff or pilot balloon (the small balloon that shows whether the cuff is inflated) losing air or failing to stay inflated, sometimes soon after placement, which led to leaks in one case. One report says the cuff was found deflated after intubation, and another says it had to be reinflated and monitored. No patient injury was reported in the cases that stated it.

    5 reports: 3003674698-2025-01019, 3003674698-2025-00948, 16655761, 3003898360-2012-00614, 3003898360-2010-00382

  • Reports describe a cuff pressure gauge (a device that measures cuff pressure) leaking air during use, which made its indicator needle drop. In one report the needle did not return to zero after air was released. No patient injury was reported.

    3 reports: 3012307300-2021-10086, 3012307300-2021-11737, 3012307300-2022-00241

  • Two reports say a plastic lock on the product pulled away from its adhesive backing in paralyzed patients. The reports give no further details about the effect on patients.

    2 reports: 3012307300-2021-08702, 3012307300-2021-08703

  • Two reports describe an obstruction or narrowing inside the tube near its tip that caught a suction catheter (a thin tube used to clear secretions). In one case the nurse felt the same resistance when reinserting a tube from the same lot, and the manufacturer examined tubes and found a narrowing. No patient injury was reported.

    2 reports: 3003898360-2011-00479, 3003898360-2011-00244

  • One report describes air leaking from endotracheal tubes during intubation, after which the patient died. The narrative also describes the patient's worsening COVID-19 and breathing before the event, so it does not establish whether the tube caused the death.

    Report: 13677981

Written by AI from the narratives of the 19 newest reports that have one, received Aug 19, 2010 to Jul 24, 2025. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
31in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Product codes classified under the same regulation.

Watch LNZ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get LNZ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LNZ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.