FDA product code
LNR: System, Photopheresis, Extracorporeal (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class III
- Regulation
- None listed
- Review panel
- Gastroenterology and Urology
- Premarket route
- PMA
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- PMA decisions
- 1081 original PMA, the rest supplements
- Median review time
- 29 daysthe latest 25 decisions
- Recall records
- 100 in the last 12 months
- Adverse event reports
- 89last 12 months, 0 deaths
PMA decisions
Original PMAs and supplements for product code LNR per year, by decision date, 108 since 1987. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 8 |
| 2018 | 4 |
| 2019 | 2 |
| 2020 | 1 |
| 2021 | 2 |
| 2022 | 3 |
| 2023 | 3 |
| 2024 | 0 |
| 2025 | 3 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| P860003 S112 | THERAKOS® CELLEX® Photopheresis System (CELLEX), THERAKOS® CELLEX® Photopheresis Procedural Kit (CLXUSA and CLXECP), THETherakos Development Limited | Nov 21, 2025242 days |
| P860003 S113 | THERAKOS® CELLEX® Photopheresis System Procedural KitTherakos Development Limited | Jun 30, 202528 days |
| P860003 S111 | THERAKOS CELLEX Photopheresis System (CELLEX), THERAKOS CELLEX Photopheresis Procedural Kit (CLXUSA and CLXECP), THERAKTherakos Development Limited | Feb 27, 2025443 days |
| P860003 S110 | THERAKOS CELLEX Photopheresis System (CELLEX), THERAKOS CELLEX Photopheresis Procedural Kit (CLXUSA and CLXECP), THERAKTherakos Development Limited | Aug 10, 202327 days |
| P860003 S103 | Therakos CELLEX Photopheresis KitTherakos Development Limited | Jun 16, 2023994 days |
| P860003 S109 | THERAKOS CELLEX Photopheresis System (CELLEX), THERAKOS CELLEX Photopheresis Procedural Kit (CLXUSA and CLXECP), THERAKTherakos Development Limited | Mar 13, 2023103 days |
| P860003 S108 | THERAKOS CELLEX Photopheresis System (CELLEX), THERAKOS CELLEX Photopheresis Procedural Kit (CLXUSA and CLXECP), THERAKOTherakos Development Limited | Sep 23, 202228 days |
| P860003 S107 | THERAKOS CELLEX Photopheresis System (CELLEX), THERAKOS CELLEX Photopheresis Procedural Kit (CLXUSA and CLXECP),THERAKOSTherakos Development Limited | May 25, 202228 days |
| P860003 S106 | THERAKOS CELLEX Photopheresis System (CELLEX), THERAKOS CELLEX Photopheresis Procedural Kit (CLXUSA and CLXECP), THERAKOTherakos Development Limited | Mar 11, 202230 days |
| P860003 S104 | THERAKOS CELLEX Photopheresis System (CELLEX), THERAKOS CELLEX Photopheresis Procedural Kit (CLXUSA/CLXECP),THERAKOS CELTherakos Development Limited | Oct 1, 202128 days |
Recalls
Recall records for product code LNR per year, by the date the recall began. Each recalled product is one record; these 10 records belong to 10 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 2 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 1 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1822-2026Class II | THERAKOS DEVELOPMENT LIMITEDIncreased difficulty in installing the centrifuge bowl onto the centrifuge bowl holder. Improper installation may cause the centrifuge bowl to dislodge, result… | May 16, 2025 |
| Z-0567-2022Class II | Mallinckrodt Pharmaceuticals Ireland LtdThis recall was initiated to recover a Dunnage Case, which is a case of three (3) CLXUSA kits. This Dunnage Case was shipped on 02-Dec-2021. Dunnage is used du… | Dec 10, 2021 |
| Z-0212-2022Class II | Therakos, Inc.Product was released prior to all testing being completed. If used and a drive tube leak were to occur, may cause illness or injury. | Oct 4, 2021 |
| Z-1322-2016Class II | Therakos IncThe Mallinckrodt (Therakos) post-market monitoring process detected an increased trend in tubing leaks within the pump tubing organizer, associated with a port… | Dec 21, 2015 |
| Z-0595-2012 | Therakos, Inc.There have been three confirmed reports of post reinfusion hemolysis or hemoglobinuria in patients treated on the Therakos Cellex Photopheresis System. | Sep 1, 2011 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code LNR. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 261 |
| 2018 | 183 |
| 2019 | 161 |
| 2020 | 141 |
| 2021 | 114 |
| 2022 | 97 |
| 2023 | 83 |
| 2024 | 151 |
| 2025 | 148 |
| 2026 (so far) | 80 |
Last 12 months by event type
- Deaths0
- Injuries4
- Malfunctions85
- Other or not stated0
Most reported device problems, last 12 months
- Fluid/Blood Leak68
- Coagulation in Device or Device Ingredient13
- Adverse Event Without Identified Device or Use Problem4
- Break2
- Material Twisted/Bent2
- Material Split, Cut or Torn1
In plain English: what the newest reports describe Written by AI
Seven reports describe the drive tube, the tube near the centrifuge bowl, leaking or breaking during treatment, and the treatment was stopped. Descriptions vary: a fine cut, a circular notch, a twisted top, or metal shavings in the chamber. The reports do not give a single cause.
7 reports: 3036773437-2026-00039, 3036773437-2026-00040, 3036773437-2026-00045, 3036773437-2026-00046, 3036773437-2026-00054, 3036773437-2026-00056, 3036773437-2026-00072
Three reports describe the centrifuge bowl, the spinning chamber that separates blood components, leaking or breaking. One report places the leak between the base and body of the bowl, and another says it broke at the start of treatment. Treatments were stopped.
3 reports: 3036773437-2026-00051, 3036773437-2026-00053, 3036773437-2026-00055
Two reports describe blood leaking from the pressure dome, the part connected to the pressure sensor. One says the dome was picked up during treatment, spilling blood onto the pressure transducer and triggering a system pressure alarm. The other says blood entered the transducer's pinhole and the deck.
2 reports: 3036773437-2026-00050, 3036773437-2026-00065
Two reports describe a leak or break in the pump tubing organizer, the housing that holds the pump tubing. In one, tubing broke inside it during a return pump error alarm. In the other, fluid leaked from the return reservoir during priming, before the patient was connected.
2 reports: 3036773437-2026-00047, 3036773437-2026-00049
Two reports describe blood clotting in the return line along with a return pressure alarm. In one case the manufacturer reviewed photos and said they did not confirm clots, and the most likely cause could not be determined.
2 reports: 3036773437-2026-00048, 3036773437-2026-00060
Written by AI from the narratives of the 19 newest reports that have one, received May 5, 2026 to Oct 14, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 12in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 10registered establishments that list this product code
Watch LNR in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get LNR every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LNR. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:LNRRetrieved Nov 28, 2026, 10:29 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:LNRRetrieved Nov 29, 2026, 8:10 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:LNR · count decision_dateRetrieved Nov 28, 2026, 10:29 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:LNR · count pma_numberRetrieved Nov 28, 2026, 10:29 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:LNRRetrieved Nov 29, 2026, 8:10 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:LNR · count event_date_initiatedRetrieved Nov 28, 2026, 10:29 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:LNR · count res_event_numberRetrieved Nov 28, 2026, 10:29 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1822-2026" "Z-0567-2022" "Z-0212-2022" "Z-1322-2016" "Z-0595-2012")Retrieved Nov 29, 2026, 8:10 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:LNR AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 8:10 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:LNR AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 8:10 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:LNR AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 3:18 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:LNRRetrieved Nov 28, 2026, 10:29 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:LNRRetrieved Nov 28, 2026, 10:29 PM UTC. FDA data updated Nov 16, 2026.