Product codes

FDA product code

KWS: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (FDA product code)

Follow KWS: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 888.3660
Review panel
Orthopedic
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
1923 in the last 12 months
Median review time
139 daysthe latest 25 decisions
Recall records
1534 in the last 12 months
Adverse event reports
2,501last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code KWS per year, by decision date, 192 since 1980. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20177
20184
20199
20203
20215
20225
20234
20242
20253
2026 (so far)3

Latest decisions

NumberDevice and applicantDecision and review time
K263583 Tornier Humeral Reconstruction System (HRS) Tuberosity BodyTornier, Inc. Oct 28, 202628 days
K260721 Tornier Perform Advanced GlenoidTornier, Inc. Jul 22, 2026139 days
K254084 AETOS Shoulder System - CONCELOC GlenoidsSmith & Nephew, Inc. Apr 6, 2026109 days
K252418 Catalyst F1x Shoulder SystemCatalyst Orthoscience, Inc. Nov 6, 202597 days
K252416 AETOS Shoulder System Meta Humeral Prosthesis Size 0Smith & Nephew, Inc. Oct 29, 202589 days
K241292 MyShoulder Planner (5.3SSWPL)Medacta International S.A. Jan 30, 2025267 days
K241878 Tornier Humeral Reconstruction System (Tornier HRS); Tornier Perform Humeral System - Stem (Tornier PHS-Stem)Stryker Corporation (Tornier, Inc.) Dec 6, 2024161 days
K241609 Tornier Humeral Reconstruction System (Tornier HRS)Stryker Corporation (Tornier, Inc.) Sep 10, 202497 days
K230513 Arthrex Univers Apex OptiFit Humeral StemArthrex, Inc. Sep 26, 2023214 days
K222592 AltiVate® Anatomic Shoulder AG e+™ with MarkersEncore Medical L.P. Jun 23, 2023301 days

Recalls

Recall records for product code KWS per year, by the date the recall began. Each recalled product is one record; these 153 records belong to 52 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20176
20186
20192
202011
20212
20220
20235
202414
20254
2026 (so far)3

Latest recalls

Recall and classFirm and reasonBegan
Z-3200-2026Class II Howmedica Osteonics Corp.Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential… Jul 30, 2026
Z-1769-2026Class II Tornier, IncAffected products were incorrectly labeled as Tornier HRS Max products. These parts are compatible with the Tornier HRS system only, and are incompatible with… Mar 5, 2026
Z-1458-2026Class II Encore Medical, LPKnee and Humeral socket implants contain incorrect labeling. Jan 15, 2026
Z-1237-2026Class II Tornier, IncA specific lot of screws is incorrectly labeled. Screws are labeled as 5.0mmx18mm but actual screws are 5.00mmx14mm. If mismatch is detected during surgery, th… Dec 19, 2025
Z-2546-2025Class II Encore Medical, LPTheir is a potential that the reamer may kick or bind up during or immediately prior to use. Jul 18, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KWS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20171,681
20181,529
20191,728
20201,564
20211,358
20221,268
20231,750
20242,122
20252,315
2026 (so far)2,308

Last 12 months by event type

  • Deaths0
  • Injuries2,330
  • Malfunctions171
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem940
  2. Device Dislodged or Dislocated293
  3. Unstable251
  4. Patient Device Interaction Problem244
  5. Insufficient Device Problem Information201
  6. Fracture196

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
10,911in the FDA’s Global Unique Device Identification Database
Establishment listings
1,754registered establishments that list this product code

Watch KWS in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KWS every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KWS. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.