Product codes

FDA product code

KTN: System, Test, Infectious Mononucleosis (FDA product code)

Follow KTN: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 866.5640
Review panel
Microbiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
590 in the last 12 months
Median review time
80 daysthe latest 25 decisions
Recall records
90 in the last 12 months
Adverse event reports
49last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code KTN per year, by decision date, 59 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20181
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K181436 OSOM Mono Test; Sure Vue Signature Mono; ImmunoCard STAT Mono; Cardinal Health Mono II Rapid TestSEKISUI Diagnostics, LLC Jun 22, 201821 days
K042272 ACON MONONUCLEOSIS RAPID TEST STRIP (WHOLE BLOOD/SERUM/PLASMA)ACON Laboratories, Inc. Feb 28, 2005189 days
K030215 BIORAPID MONONUCLEOSISInstrumentation Laboratory CO Feb 24, 200334 days
K012901 COLOR-MONOGENInstrumentation Laboratory CO Sep 27, 200129 days
K982634 DRYSPOT INFECTIOUS MONONUCLEOSIS KITOxoid , Ltd. Jan 28, 1999184 days
K981946 CLEARVIEW IMUnipath , Ltd. Dec 10, 1998190 days
K972457 MONOCOL/LEX-IM TESTImmunostics Inc., Dec 1, 1997153 days
K972231 OSOM MONO TEST 143Wyntek Diagnostics, Inc. Aug 26, 199771 days
K963425 GENZYME DIAGNOSTICS CONTRAST MONOGenzyme Diagnostics Feb 25, 1997179 days
K961024 BIOSIGN MONO-PLUS WB,BIOSIGN MONO WB,MONO-PLUS WB,ACCUSIGN MONO WBPrinceton BioMeditech Corp. Feb 4, 1997327 days

Recalls

Recall records for product code KTN per year, by the date the recall began. Each recalled product is one record; these 9 records belong to 3 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2265-2016Class III Alere San Diego, Inc.The Positive Control information referencing human plasma as the antibody material described in the product labeling and packaging is incorrect. Jun 22, 2016
Z-2266-2016Class III Alere San Diego, Inc.The Positive Control information referencing human plasma as the antibody material described in the product labeling and packaging is incorrect. Jun 22, 2016
Z-2267-2016Class III Alere San Diego, Inc.The Positive Control information referencing human plasma as the antibody material described in the product labeling and packaging is incorrect. Jun 22, 2016
Z-2268-2016Class III Alere San Diego, Inc.The Positive Control information referencing human plasma as the antibody material described in the product labeling and packaging is incorrect. Jun 22, 2016
Z-2269-2016Class III Alere San Diego, Inc.The Positive Control information referencing human plasma as the antibody material described in the product labeling and packaging is incorrect. Jun 22, 2016

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KTN. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20192
20202
20210
20220
20230
20241
20250
2026 (so far)49

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions48
  • Other or not stated1

Most reported device problems, last 12 months

  1. Incorrect, Inadequate or Imprecise Result or Readings20
  2. False Negative Result18
  3. False Positive Result2
  4. Improper or Incorrect Procedure or Method2
  5. No Device Output2
  6. Output Problem2

In plain English: what the newest reports describe Written by AI

  • The positive control, which should show a positive result to confirm the test works, often did not. Multiple reports describe this, and in one the controls were not expired, yet results changed from positive in June to negative in July. In another, the test missed the positive control, and retesting with other tests and earlier controls gave the same false negatives.

    9 reports: 1417592-2026-59623, 1417592-2026-55360, 1417592-2026-49038, 1417592-2026-49146, 1417592-2026-45087, 1417592-2026-32646, 1417592-2026-09430, 1417592-2026-36311, 1417592-2026-49892

  • Some kit boxes failed the manufacturer's quality control checks, including one box that failed twice. In one report, tests passed quality control at first but later failed on a rerun after faint lines appeared.

    4 reports: 1417592-2026-51932, 1417592-2026-48548, 1417592-2026-30399, MW6001194

  • The positive test line was reported as faint or only partly across the test window. In one report, true positive patients came up negative on the new kit.

    3 reports: 1417592-2026-44298, 1417592-2026-32646, 1417592-2026-30399

  • In two reports, both the positive and negative controls read as negative, so the test could not tell a known positive from a known negative. One lab said it ran both kits with a specific pipette and two drops of developer, and the result was the same.

    2 reports: 1417592-2026-55443, 1417592-2026-48597

  • Test results showed the wrong number of lines. One report describes three lines instead of two, with an extra middle line, and another describes only the test line appearing with no control line.

    2 reports: 1417592-2026-50705, 1417592-2026-07473

Written by AI from the narratives of the 20 newest reports that have one, received Jul 22, 2026 to Oct 7, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
76in the FDA’s Global Unique Device Identification Database
Establishment listings
31registered establishments that list this product code

Watch KTN in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KTN every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KTN. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.