FDA product code
KST: System, Blood Collection, Vacuum-Assisted, Manual (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 864.9125
- Review panel
- Hematology
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 00 in the last 12 months
- Median review time
- Not availablethe latest 0 decisions
- Recall records
- 40 in the last 12 months
- Adverse event reports
- 22last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code KST per year, by decision date. Review time is the days from receipt to decision.
No decisions on record for this product code.
Recalls
Recall records for product code KST per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 4 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1636-2016Class I | Hummingbird MedHummingbird Med Devices, Inc. is recalling ABG-HM-1 Hummi Micro Draw Blood Transfer because the connection between the "Hummi" Y connector and the yellow cannu… | Oct 1, 2015 |
| Z-1908-2016Class I | Hummingbird MedHummingbird Med Devices, Inc. is recalling the Hummi Micro Draw because of insertion difficulties. | Mar 11, 2015 |
| Z-1131-2013Class II | Heritage Labs International LLCThe product has a Lithium Heparin contaminant which could adversely affect coagulation results potentially causing erroneous lab results. | Feb 6, 2013 |
| Z-3028-2011 | Becton Dickinson & CompanyBD Vacutainer Push Button Blood Collection Set can potentially undergo cannula separation from the hub. | Apr 22, 2011 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code KST. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 1 |
| 2018 | 7 |
| 2019 | 5 |
| 2020 | 2 |
| 2021 | 0 |
| 2022 | 1 |
| 2023 | 8 |
| 2024 | 5 |
| 2025 | 3 |
| 2026 (so far) | 22 |
Last 12 months by event type
- Deaths0
- Injuries2
- Malfunctions20
- Other or not stated0
Most reported device problems, last 12 months
- Decoupling4
- Fluid/Blood Leak4
- Physical Resistance/Sticking3
- Adverse Event Without Identified Device or Use Problem2
- Connection Problem2
- Failure to Disconnect2
In plain English: what the newest reports describe Written by AI
A transfer hub or cannula broke off, and one report says a line split near a connector, which was replaced. No harm to the patient was reported in the cannula case.
4 reports: 1417592-2026-08453, 2243072-2024-01017, 2243072-2026-00056, MW5153056
Blood leaked or sprayed out of the device, usually at the cap or hub end, when the needle cap stayed on the needle or the rubber sheath did not fully retract. Reports say the hub is narrower and the tube is hard to remove, and the blood loss meant the patient had to be stuck again.
3 reports: 1417592-2026-59415, 1417592-2026-48662, 1417592-2025-00032
Blood filled or leaked from the hub of the device, and the patient had to be stuck again. One report says blood leaked from the non-patient end of the assembly in 5-10 devices, and the tubes were soiled so samples had to be redrawn.
3 reports: 1417592-2025-00043, 2243072-2024-01017, 1417592-2025-00042
Blood sprayed onto patients when drawing from an arterial or IV line through the adapter, and tubes felt pressurized. One report says a crack was found at the clear joining section, and another says blood sprayed onto an infant.
3 reports: 3003560965-2026-00009, MW5152009, MW5151773
The tube popped off or came loose while blood was being drawn, and one report says the hubs do not thread correctly with butterfly sets or needles.
2 reports: 1417592-2026-56526, 1417592-2026-36558
Written by AI from the narratives of the 19 newest reports that have one, received Feb 16, 2024 to Oct 7, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 84in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 83registered establishments that list this product code
Other codes under 21 CFR 864.9125
Product codes classified under the same regulation.
Watch KST in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get KST every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KST. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:KSTRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KSTRetrieved Nov 29, 2026, 11:13 PM UTC.
- device/510k · search product_code:KST · count decision_dateRetrieved Nov 29, 2026, 11:13 PM UTC.
- device/recall · search product_code:KSTRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KST · count event_date_initiatedRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KST · count res_event_numberRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1636-2016" "Z-1908-2016" "Z-1131-2013" "Z-3028-2011")Retrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KST AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KST AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KST AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:KSTRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:KSTRetrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:864.9125Retrieved Nov 29, 2026, 11:13 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil