KOI: Stimulator, Nerve, Peripheral, Electric (FDA product code)

Follow KOI: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.2775
Review panel
Anesthesiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
291 in the last 12 months
Median review time
191 daysthe latest 25 decisions
Recall records
10 in the last 12 months
Adverse event reports
2last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code KOI per year, by decision date, 29 since 1984. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20182
20191
20201
20212
20223
20230
20241
20252
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K261098 TetraGraph Neuromuscular Transmission Monitor (SEN 2015)Accessories:TetraSens (SEN 2012)TetraSens Pediatric (SEN 2013)TetraSensitive (SEN 2016)TetraHub (SEN 2017)Senzime AB May 22, 202650 days
K250887 Neuromuscular Transmission Monitor TOF3D (2510091)MIPM Mammendorfer Institut für Physik und Medizin GmbH Oct 21, 2025210 days
K243339 WiTOFIdmed Jun 23, 2025241 days
K242525 iTOF®Nerbio Medical Software Platforms, Inc. Dec 5, 2024101 days
K220530 Tetragraph Neuromuscular Transmission MonitorSenzime AB Aug 17, 2022174 days
K220976 Life Scope PT BSM-1700 Series Bedside MonitorNihon Kohden Corporation Jul 21, 2022108 days
K212434 Neuromuscular Transmission Monitor TOF3DMIPM Mammendorfer Institut für Physik und Medizin GmbH May 5, 2022274 days
K213316 Life Scope PT BSM-1700 Series, AY Series, Data Acquisition Unit, LIFE SCOPE BSM 6000 SERIES BEDSIDE MONITORING SYSTEM, Nihon Kohden CSM-1901 BEDSIDE MONITORING SYSTEMNihon Kohden Corporation Dec 29, 202186 days
K201949 Smart Cable NMT Module and Accessories, Life Scope BSM 3000 Series and Life Scope BSM 6000 SeriesNihon Kohden Corporation May 2, 2021293 days
K192958 TwitchView SystemBlink Device Company Apr 2, 2020163 days

Recalls

Recall records for product code KOI per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1640-2014Class II GE Healthcare, LLCWhen the E-NMT-01 module is used in conjunction with the ElectroSensor, the Neuromuscular Transmission (NMT) values may indicate a deeper level of muscle relax… Apr 9, 2014

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KOI. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20181
20194
20204
20213
20224
20231
20242
20255
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Break1
  2. Communication or Transmission Problem1

In plain English: what the newest reports describe Written by AI

  • Multiple reports describe burns on patients during or after use of nerve-monitoring equipment, and the reports do not say which part of the equipment caused them. One report describes a 5 mm burn near the base of the thumb that was expected to leave likely permanent but small damage.

    5 reports: 9610816-2025-001103, 9610816-2025-001072, MW5101760, MW5101761, MW5101762

  • Several reports say the monitor gave inaccurate readings, and in some cases a paralytic drug was given based on them. One report says the monitor may be overreading muscle response, which could lead to too much paralytic being given. Another says medical treatment was needed to prevent lasting harm, and another says a dose was repeated after a reading of 94%.

    3 reports: 9828800, 9610105-2020-00004, 8030229-2025-05777

  • Two reports describe skin coming off a patient's hand when the adhesive sticker or electrode that is placed on the hand for the monitor was removed.

    2 reports: MW5111221, MW5111223

  • One report describes a break in the cable used for a nerve test called train of four (TOF), found after two small skin lesions appeared on a 13-month-old child's hand. The nursing team received no readings from the equipment, and the facility called the injury serious.

    Report: 9610816-2026-100691

  • One report describes the monitor failing to sound its alarm for train of four readings even after the reading reached the alarm limit. The manufacturer's specialist reported that the problem stayed after copying settings from a working device, and the manufacturer's investigation is still ongoing.

    Report: 8030229-2024-04187

Written by AI from the narratives of the 18 newest reports that have one, received Mar 13, 2020 to Apr 13, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
143in the FDA’s Global Unique Device Identification Database
Establishment listings
123registered establishments that list this product code

Product codes classified under the same regulation.

Watch KOI in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KOI every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KOI. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.