Product codes

FDA product code

KOC: Accessories, Blood Circuit, Hemodialysis (FDA product code)

Follow KOC: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.5820
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
Yes
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
1820 in the last 12 months
Median review time
99 daysthe latest 25 decisions
Recall records
174 in the last 12 months
Adverse event reports
29last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code KOC per year, by decision date, 182 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20180
20190
20201
20210
20220
20232
20240
20252
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K242176 BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series (AL-ADC-E(U), AL-CDC-E(U), C18RDC-E(U), C18BDD-E(U), C18SFD-E(U)NIKKISO CO., LTD. May 15, 2025295 days
K242479 BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series AL-ADC-PU, AL-CDC-PU, C18RDC-PU, C18BDD-PU, C18SFD-PUNIKKISO CO., LTD. May 15, 2025267 days
K231589 Blood Tubing Lines for Hemodialysis AV06C-ENIKKISO CO., LTD. Jul 28, 202357 days
K230514 Blood Tubing Lines for Hemodialysis AL Series (Archloop), Blood Tubing Lines for Hemodialysis C18 SeriesNIKKISO CO., LTD. Jun 16, 2023112 days
K201207 CombiSet SMARTECH Hemodialysis Blood Tubing Set with attached Priming Set and Integrated Crit-Line Technology, CombiSet SMARTECH Hemodialysis Blood Tubing Set with attached Priming Set and Intergrated Crit-Line Technology, no Heparin LineFresenius Medical Care Renal Therapies Group, LLC Sep 18, 2020136 days
K172238 CAREline Airless Hemodialysis Blood Tubing SetsFresenius Medical Care Renal Therapies Group, LLC Dec 14, 2017141 days
K160749 CRIT-LINE III Blood Chamber IIFresenius Medical Care Renal Therapies Group, LLC Apr 15, 201628 days
K152953 CRIT-LINE CLIP (CLIC) BLOOD CHAMBERFresenius Medical Care North America Nov 5, 201529 days
K141997 CRIT-LINE IV SYSTEMFresenius Medical Care Apr 1, 2015252 days
K141281 CRIT-LINE CLIP (CLIC) BLOOD CHAMBERFresenius Medical Care Renal Therapies Group, LLC Aug 14, 201490 days

Recalls

Recall records for product code KOC per year, by the date the recall began. Each recalled product is one record; these 17 records belong to 10 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20183
20190
20200
20210
20220
20230
20240
20250
2026 (so far)4

Latest recalls

Recall and classFirm and reasonBegan
Z-3084-2026Class II Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… Aug 10, 2026
Z-3085-2026Class II Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… Aug 10, 2026
Z-3086-2026Class II Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… Aug 10, 2026
Z-3087-2026Class II Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… Aug 10, 2026
Z-0759-2019Class II Stihler Electronic GmbhPRISMAFLO II and PRISMAFLO II S Heating Profile only and not the Control Unit, damage may result in a hotspot on the Heating Profile, may cause low level skin… Sep 6, 2018

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KOC. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201723
201837
201956
202020
202133
202226
202316
202418
202550
2026 (so far)26

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions29
  • Other or not stated0

Most reported device problems, last 12 months

  1. Fluid/Blood Leak27
  2. Crack5
  3. Fire2

In plain English: what the newest reports describe Written by AI

  • Reports describe cracks in the blood tubing that let blood leak out. In one case the manufacturer's lot of combi sets had cracks found before treatment, and staff worry a tiny leak may have lowered fluid in the arterial chamber during setup. In another, a crack formed when a part of the device rotated during an access flow test.

    4 reports: MW5189643, MW5189644, 0008030665-2026-00959, 0008030665-2026-00884

  • Reports describe tubing connections coming apart during treatment, causing blood to leak. Causes mentioned include a line pulling out of the blood line, a loose cap on a heparin line, and a crit line separating from the dialyzer. Blood loss was reported as unknown or about 100 to 300 mL.

    4 reports: 0008030665-2026-01564, 0008030665-2026-00566, 0008030665-2026-00489, 0008030665-2026-00380

  • Reports describe air getting into the blood tubing during treatment, with the machine's air alarm sounding in some cases. Staff stopped treatment and, in some cases, could not return the patient's blood. Estimated blood loss ranged from about 50 to 300 mL.

    3 reports: 0008030665-2026-00628, 0008030665-2026-00308, 0008030665-2026-00437

  • Two reports describe a small blood leak from the glued joint just below the crit-line blood chamber. In one report, no visible damage was found at the leak, and staff estimated the blood loss at under 2 mL. The patient was given antibiotics as a precaution in the second report.

    2 reports: 0008030665-2026-00531, 0008030665-2026-00532

  • One report describes about 300 mL of blood loss during treatment, with no defect found in the bloodline and no problems during priming. The cause was not identified in the report.

    Report: 0008030665-2026-00556

Written by AI from the narratives of the 15 newest reports that have one, received Feb 13, 2026 to Jul 1, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
137in the FDA’s Global Unique Device Identification Database
Establishment listings
82registered establishments that list this product code

Watch KOC in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KOC every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KOC. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.