FDA product code
KOC: Accessories, Blood Circuit, Hemodialysis (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.5820
- Review panel
- Gastroenterology and Urology
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- Yes
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- 510(k) and De Novo decisions
- 1820 in the last 12 months
- Median review time
- 99 daysthe latest 25 decisions
- Recall records
- 174 in the last 12 months
- Adverse event reports
- 29last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code KOC per year, by decision date, 182 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 1 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 2 |
| 2024 | 0 |
| 2025 | 2 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K242176 | BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series (AL-ADC-E(U), AL-CDC-E(U), C18RDC-E(U), C18BDD-E(U), C18SFD-E(U)NIKKISO CO., LTD. | May 15, 2025295 days |
| K242479 | BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series AL-ADC-PU, AL-CDC-PU, C18RDC-PU, C18BDD-PU, C18SFD-PUNIKKISO CO., LTD. | May 15, 2025267 days |
| K231589 | Blood Tubing Lines for Hemodialysis AV06C-ENIKKISO CO., LTD. | Jul 28, 202357 days |
| K230514 | Blood Tubing Lines for Hemodialysis AL Series (Archloop), Blood Tubing Lines for Hemodialysis C18 SeriesNIKKISO CO., LTD. | Jun 16, 2023112 days |
| K201207 | CombiSet SMARTECH Hemodialysis Blood Tubing Set with attached Priming Set and Integrated Crit-Line Technology, CombiSet SMARTECH Hemodialysis Blood Tubing Set with attached Priming Set and Intergrated Crit-Line Technology, no Heparin LineFresenius Medical Care Renal Therapies Group, LLC | Sep 18, 2020136 days |
| K172238 | CAREline Airless Hemodialysis Blood Tubing SetsFresenius Medical Care Renal Therapies Group, LLC | Dec 14, 2017141 days |
| K160749 | CRIT-LINE III Blood Chamber IIFresenius Medical Care Renal Therapies Group, LLC | Apr 15, 201628 days |
| K152953 | CRIT-LINE CLIP (CLIC) BLOOD CHAMBERFresenius Medical Care North America | Nov 5, 201529 days |
| K141997 | CRIT-LINE IV SYSTEMFresenius Medical Care | Apr 1, 2015252 days |
| K141281 | CRIT-LINE CLIP (CLIC) BLOOD CHAMBERFresenius Medical Care Renal Therapies Group, LLC | Aug 14, 201490 days |
Recalls
Recall records for product code KOC per year, by the date the recall began. Each recalled product is one record; these 17 records belong to 10 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 3 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 4 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-3084-2026Class II | Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… | Aug 10, 2026 |
| Z-3085-2026Class II | Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… | Aug 10, 2026 |
| Z-3086-2026Class II | Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… | Aug 10, 2026 |
| Z-3087-2026Class II | Fresenius Medical Care Renal Therapies Group, LLCHeightened probability of blood leak from the connection between the Arterial Alpha Clip and the main line or pump segment. Leak during treatment may lead to b… | Aug 10, 2026 |
| Z-0759-2019Class II | Stihler Electronic GmbhPRISMAFLO II and PRISMAFLO II S Heating Profile only and not the Control Unit, damage may result in a hotspot on the Heating Profile, may cause low level skin… | Sep 6, 2018 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code KOC. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 23 |
| 2018 | 37 |
| 2019 | 56 |
| 2020 | 20 |
| 2021 | 33 |
| 2022 | 26 |
| 2023 | 16 |
| 2024 | 18 |
| 2025 | 50 |
| 2026 (so far) | 26 |
Last 12 months by event type
- Deaths0
- Injuries0
- Malfunctions29
- Other or not stated0
Most reported device problems, last 12 months
- Fluid/Blood Leak27
- Crack5
- Fire2
In plain English: what the newest reports describe Written by AI
Reports describe cracks in the blood tubing that let blood leak out. In one case the manufacturer's lot of combi sets had cracks found before treatment, and staff worry a tiny leak may have lowered fluid in the arterial chamber during setup. In another, a crack formed when a part of the device rotated during an access flow test.
4 reports: MW5189643, MW5189644, 0008030665-2026-00959, 0008030665-2026-00884
Reports describe tubing connections coming apart during treatment, causing blood to leak. Causes mentioned include a line pulling out of the blood line, a loose cap on a heparin line, and a crit line separating from the dialyzer. Blood loss was reported as unknown or about 100 to 300 mL.
4 reports: 0008030665-2026-01564, 0008030665-2026-00566, 0008030665-2026-00489, 0008030665-2026-00380
Reports describe air getting into the blood tubing during treatment, with the machine's air alarm sounding in some cases. Staff stopped treatment and, in some cases, could not return the patient's blood. Estimated blood loss ranged from about 50 to 300 mL.
3 reports: 0008030665-2026-00628, 0008030665-2026-00308, 0008030665-2026-00437
Two reports describe a small blood leak from the glued joint just below the crit-line blood chamber. In one report, no visible damage was found at the leak, and staff estimated the blood loss at under 2 mL. The patient was given antibiotics as a precaution in the second report.
2 reports: 0008030665-2026-00531, 0008030665-2026-00532
One report describes about 300 mL of blood loss during treatment, with no defect found in the bloodline and no problems during priming. The cause was not identified in the report.
Report: 0008030665-2026-00556
Written by AI from the narratives of the 15 newest reports that have one, received Feb 13, 2026 to Jul 1, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 137in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 82registered establishments that list this product code
Other codes under 21 CFR 876.5820
Product codes classified under the same regulation.
Watch KOC in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get KOC every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KOC. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:KOCRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KOCRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KOC · count decision_dateRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:KOCRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KOC · count event_date_initiatedRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KOC · count res_event_numberRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-3084-2026" "Z-3085-2026" "Z-3086-2026" "Z-3087-2026" "Z-0759-2019")Retrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KOC AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KOC AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KOC AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:KOCRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:KOCRetrieved Nov 29, 2026, 5:00 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.5820Retrieved Nov 28, 2026, 5:18 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil