FDA product code
KNW: Instrument, Biopsy (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.1075
- Review panel
- General and Plastic Surgery
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 3669 in the last 12 months
- Median review time
- 154 daysthe latest 25 decisions
- Recall records
- 1075 in the last 12 months
- Adverse event reports
- 3,485last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code KNW per year, by decision date, 366 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 8 |
| 2018 | 7 |
| 2019 | 5 |
| 2020 | 8 |
| 2021 | 9 |
| 2022 | 8 |
| 2023 | 7 |
| 2024 | 5 |
| 2025 | 12 |
| 2026 (so far) | 8 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262531 | OnControl Powered Bone Access Systems; OnControl Bone Marrow Aspiration System; OnControl Bone Marrow Biopsy System; OnControl Bone Lesion Biopsy System; OnControl Power DriverTeleflex Medical, LLC | Oct 27, 202697 days |
| K260517 | Automatic Core Biopsy InstrumentZhejiang Curaway Medical Technology Co., Ltd. | Aug 28, 2026192 days |
| K262571 | EnCor EnCompass™ Breast Biopsy and Tissue Removal SystemBard Peripheral Vascular, Inc. | Aug 14, 202621 days |
| K262792 | Brevera Biopsy System with CorLumina Imaging Technology (BREVDISP09)Hologic, Inc. | Aug 12, 20266 days |
| K260572 | Marrow MarxmanMedimetrix, LLC | Aug 4, 2026166 days |
| K261196 | Promisemed VeriEcto Automatic Biopsy NeedlesPromisemed Hangzhou Meditech Co., Ltd. | May 12, 202629 days |
| K260365 | Mammotome Prima™ MR Dual Vacuum-Assisted Breast Biopsy System Control Module; Mammotome Prima™ MR Dual Vacuum-Assisted Breast Biopsy System Disposable Probe, 8 gauge; Mammotome Prima™ MR Dual Vacuum-Assisted Breast Biopsy System Disposable Targeting Set, 8 gauge; Mammotome Prima™ MR Dual Vacuum-Assisted Breast Biopsy System Foot Switch; Mammotome Prima™ MR Dual Vacuum-Assisted Breast Biopsy System Reusable Tray; Mammotome Prima™ MR Dual Vacuum-Assisted Breast Biopsy System Battery CharDevicor Medical Products, Inc. | Mar 4, 202628 days |
| K252795 | ZeniCore™ Automatic Biopsy Instrument (863212100 / ZeniCore Automatic Biopsy Device 12ga x 10cm with Coaxial Introducer Kit, 863212130 / ZeniCore Automatic Biopsy Device 12ga x 13cm with Coaxial Introducer Kit, 863214100 / ZeniCore Automatic Biopsy Device 14ga x 10cm with Coaxial Introducer Kit); ZeniCore™ Automatic Biopsy Instrument (863214130 / ZeniCore Automatic Biopsy Device 14ga x 13cm with CoaxialArgon Medical Devices, Inc. | Feb 23, 2026174 days |
| K252681 | EnCor EnCompass™ Breast Biopsy and Tissue Removal SystemBard Peripheral Vascular, Inc. | Dec 12, 2025109 days |
| K252183 | Resitu Slider 09 (RESL09)Resitu Medical AB | Sep 24, 202575 days |
Recalls
Recall records for product code KNW per year, by the date the recall began. Each recalled product is one record; these 107 records belong to 61 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 5 |
| 2018 | 0 |
| 2019 | 14 |
| 2020 | 5 |
| 2021 | 10 |
| 2022 | 3 |
| 2023 | 5 |
| 2024 | 2 |
| 2025 | 2 |
| 2026 (so far) | 4 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-3275-2026Class II | Bard Peripheral Vascular IncBreast biopsy and tissue removal system may experience the following errors: 1) Probe calibration and /or handheld driver failure (code HH01-00020009) , 2) Pre… | Aug 20, 2026 |
| Z-2706-2026Class I | Argon Medical Devices, IncKits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility. | Jun 1, 2026 |
| Z-2707-2026Class I | Argon Medical Devices, IncKits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility. | Jun 1, 2026 |
| Z-2709-2026Class I | Argon Medical Devices, IncKits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility. | Jun 1, 2026 |
| Z-1314-2026Class II | Hologic, IncPresence of particulates in affected devices that can be deposited into breast tissue during use. | Dec 15, 2025 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code KNW. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 760 |
| 2018 | 1,012 |
| 2019 | 4,195 |
| 2020 | 5,120 |
| 2021 | 1,020 |
| 2022 | 535 |
| 2023 | 931 |
| 2024 | 1,283 |
| 2025 | 1,695 |
| 2026 (so far) | 3,276 |
Last 12 months by event type
- Deaths0
- Injuries366
- Malfunctions3,103
- Other or not stated16
Most reported device problems, last 12 months
- Failure to Fire2,411
- Failure to Obtain Sample314
- Difficult to Remove129
- Material Twisted/Bent129
- Break106
- Adverse Event Without Identified Device or Use Problem64
In plain English: what the newest reports describe Written by AI
In four reports, the outer cannula (the outer sleeve) of the kidney biopsy instrument would not fire during ultrasound guided biopsies. Each procedure was finished with another device, and no patient injury was reported.
4 reports: 2020394-2026-03291, 2020394-2026-03293, 2020394-2026-03268, 2020394-2026-03270
In two reports, breast biopsy devices had weak or on-and-off suction (vacuum), so too little tissue was collected. One procedure switched to a different biopsy method, and one patient needs a six-month follow-up exam.
2 reports: 1222780-2026-00895, 1222780-2026-00900
In one report, a lever on a breast biopsy device became loose and would not press down fully when taking additional tissue samples. The user opened a new device to finish the procedure.
Report: 1222780-2026-00892
In one report, the trough (the channel that holds the sample) would not close fully while the needle was primed before use, and no suction could be heard. The problem was found before patient use, and another device was used.
Report: 1222780-2026-00893
In one report, a crystal-like particle came out of the tubing during a saline flush of a breast biopsy device during setup. The problem was found before patient use, and the device was removed from service.
Report: 1222780-2026-00894
Written by AI from the narratives of the 9 newest reports that have one, received Oct 29, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 5,703in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 604registered establishments that list this product code
Other codes under 21 CFR 876.1075
Product codes classified under the same regulation.
Watch KNW in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get KNW every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KNW. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:KNWRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KNWRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KNW · count decision_dateRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:KNWRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KNW · count event_date_initiatedRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KNW · count res_event_numberRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-3275-2026" "Z-2706-2026" "Z-2707-2026" "Z-2709-2026" "Z-1314-2026")Retrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNW AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNW AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNW AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 3:57 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:KNWRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:KNWRetrieved Nov 29, 2026, 4:17 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.1075Retrieved Nov 29, 2026, 5:30 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil