FDA product code
KNQ: Dilator, Esophageal (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.5365
- Review panel
- Gastroenterology and Urology
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 400 in the last 12 months
- Median review time
- 90 daysthe latest 25 decisions
- Recall records
- 214 in the last 12 months
- Adverse event reports
- 352last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code KNQ per year, by decision date, 40 since 1981. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K122924 | CRE FIXED WIRE BALLON DILATION CATHETERBoston Scientific Corp | Oct 24, 201230 days |
| K093236 | ETHICON ENDO-SURGERYOPTICAL DILATOREthicon Endo-Surgery, Inc. | Nov 10, 200926 days |
| K090183 | HERCULES 3 STAGE WIRE GUIDED DILATION BALLOONCook Endoscopy | Sep 25, 2009242 days |
| K082995 | SMART DILATORSafestitch Medical | Feb 6, 2009121 days |
| K061937 | COOK ENDOSCOPY ESOPHAGEAL DILATION BALLOONCook Endoscopy | Dec 1, 2006144 days |
| K061787 | MAXFORCE TTS SINGLE-USE BALLOON DILATORBoston Scientific Corp | Sep 21, 200687 days |
| K060302 | INSCOPE PRECISION BALLOON DILATOR - WIRE GUIDEDCordis Europa, N.V. | Apr 11, 200664 days |
| K043605 | INSCOPE 3-STAGE BALLOON DILATORCordis Europa, N.V. | Feb 4, 200536 days |
| K033936 | BARD ELIMINATOR PET BALLOON DILATORSC.R. Bard, Inc. | Jan 14, 200426 days |
| K031147 | OPTICAL DVS (DUAL VECTOR SHEARING) ESOPHAGEAL DILATOREthicon Endo-Surgery, Inc. | Jan 12, 2004277 days |
Recalls
Recall records for product code KNQ per year, by the date the recall began. Each recalled product is one record; these 21 records belong to 6 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 4 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1938-2026Class II | Diversatek HealthcareThe catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each s… | Mar 18, 2026 |
| Z-1939-2026Class II | Diversatek HealthcareThe catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each s… | Mar 18, 2026 |
| Z-1940-2026Class II | Diversatek HealthcareThe catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each s… | Mar 18, 2026 |
| Z-1941-2026Class II | Diversatek HealthcareThe catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each s… | Mar 18, 2026 |
| Z-1671-2013Class III | Boston Scientific CorporationProduct labeled with incorrect expiration date. | May 28, 2013 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code KNQ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 231 |
| 2018 | 396 |
| 2019 | 388 |
| 2020 | 364 |
| 2021 | 351 |
| 2022 | 274 |
| 2023 | 319 |
| 2024 | 268 |
| 2025 | 284 |
| 2026 (so far) | 319 |
Last 12 months by event type
- Deaths0
- Injuries14
- Malfunctions336
- Other or not stated2
Most reported device problems, last 12 months
- Burst Container or Vessel91
- Failure to Deflate56
- Material Puncture/Hole50
- Inflation Problem43
- Leak/Splash40
- Adverse Event Without Identified Device or Use Problem32
In plain English: what the newest reports describe Written by AI
The balloon would not deflate properly, so it could not be pulled back through the endoscope. In some cases the scope had to be removed and the catheter cut to free it. No patient harm was reported in these cases.
5 reports: 3005099803-2026-04250, 3005099803-2026-04253, 50994498, 50913553, 3011050570-2026-00973
Catheters and sheaths broke, or a balloon leaked, in several reports, and some breaks were found before the device reached a patient. Two reports say a section of the device did not remain inside the patient.
5 reports: 1037905-2026-00649, 1037905-2026-00650, 1037905-2026-00653, 1037905-2026-00582, 1037905-2026-00576
After dilation, the esophagus was torn or perforated, meaning a hole formed in its wall. Patients needed clips, stents, chest tubes or surgery, and some hospital stays lasted at least four days. One report says staff noted major kinks in the guidewire, and the cause was unclear in another.
5 reports: 2183446-2026-00003, 2183446-2026-00004, 2183446-2026-00005, 2183446-2026-00006, 2183446-2026-00007
The balloon burst or ruptured during inflation, in some cases before reaching the intended size. One report describes a balloon used in a blood vessel rather than the esophagus, which ruptured at a set pressure.
4 reports: MW6003219, 3005099803-2026-03941, 3005099803-2026-03787, 2124215-2026-52734
Written by AI from the narratives of the 19 newest reports that have one, received Sep 15, 2026 to Oct 23, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 642in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 85registered establishments that list this product code
Other codes under 21 CFR 876.5365
Product codes classified under the same regulation.
Watch KNQ in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get KNQ every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KNQ. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:KNQRetrieved Nov 28, 2026, 9:47 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KNQRetrieved Nov 29, 2026, 6:41 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KNQ · count decision_dateRetrieved Nov 28, 2026, 9:47 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:KNQRetrieved Nov 29, 2026, 6:41 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KNQ · count event_date_initiatedRetrieved Nov 28, 2026, 9:47 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KNQ · count res_event_numberRetrieved Nov 28, 2026, 9:47 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1938-2026" "Z-1939-2026" "Z-1940-2026" "Z-1941-2026" "Z-1671-2013")Retrieved Nov 29, 2026, 6:41 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNQ AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 6:41 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNQ AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 6:41 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNQ AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 6:41 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:KNQRetrieved Nov 28, 2026, 9:47 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:KNQRetrieved Nov 28, 2026, 9:47 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.5365Retrieved Nov 29, 2026, 6:41 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil